Literature DB >> 32416992

Reducing droplet spread during airway manipulation. Reply to Au Yong and colleagues (Br J Anaesth 2020; 125: e176-e178).

Wan Y Lim1, Patrick Wong2, Sharon G K Ong2.   

Abstract

Entities:  

Keywords:  COVID-19; aerosolisation; airway management; infection prevention; tracheal intubation

Mesh:

Substances:

Year:  2020        PMID: 32416992      PMCID: PMC7251994          DOI: 10.1016/j.bja.2020.04.074

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


× No keyword cloud information.
Editor—The coronavirus 2019 (COVID-19) pandemic has sparked innovation in infection control, drawing focus to the management of aerosol-generating procedures for the anaesthetist. We read with interest Yong and colleagues' use of a plastic tent or sheet to reduce droplet spread during airway manipulation. The authors state that the main aim of a plastic tent or sheet is related to the patient coughing or gagging on intubation, and therefore possible viral spread. All recent COVID-19 guidelines recommend rapid sequence induction and intubation for securing the airway.3, 4, 5, 6 If a patient is fully paralysed, the patient will not cough or gag; to do so would reflect poor anaesthetic technique. The tent method also has various limitations. The tent creates a reservoir of droplets. With the raised poles supporting the structure, the process of dismounting and disposal of the plastic sheet may risk contamination and viral transmission. It may not be applicable for children and patients who are anxious or claustrophobic. They mention that the tent is tall enough to allow a bougie in. If the initial laryngoscopy with a stylet-loaded tracheal tube fails, then switching to the use of a bougie may entail lifting up of the tent cover which may cause air currents that spread viral aerosol. The plastic sheet method (taped down at the sides) also compounds airway management by limiting the space available to both the intubator and assistant. Any barrier, whether a plastic sheet or one of the many intubating boxes proposed, may interfere with crisis management such as difficult intubation, crash Caesarean section, cardiopulmonary resuscitation, etc. The authors have also not provided any evidence that their technique minimises contamination, as presented by other authors including using fluorescent resin powder viewed under ultraviolet light during simulated aerosol production. We do not recommend leaving the plastic sheet in situ for the entire duration of the operation because of the risk of viral transmission via fomites. The plastic sheet can be easily and safely disposed of by simply folding down, keeping the contaminated surfaces opposed, into a smaller size, rolling into a bundle, or both. It should be discarded immediately after intubation as per local infection control measures. Emergence and extubation should be undertaken with great caution because of the risk of coughing and of aerosolisation. The authors' plastic sheet technique is intended to protect the operator, but it fails to prevent patient and work surface contamination including the patient's chest and overlying gown or surgical drapes. The use of a three-layered plastic drape configuration by Matava and colleages during a simulated cough is more successful in this respect. The authors also use a small hole cut into the plastic sheet to allow passage of the tracheal tube and breathing circuit tubing. However, the hole remains open, allowing virus transmission. Patino Montoya and colleagues proposed taping and sealing the hole to the tracheal tube. At extubation, both the tube and plastic sheet can be lifted away as a unit and discarded. However, other guidelines have advised caution using a plastic sheet for extubation, as it may inadvertently increase self-contamination. During extubation, other options to minimise coughing include administering i.v. opioids, lidocaine, or dexmedetomidine, and deep extubation if safe to do so. Antiemetics should also be given to reduce the risk of vomiting and possible viral spread. The authors' use of a Hudson's mask (with the holes taped using an occlusive dressing) as a shield for droplet dispersion may result in significant carbon dioxide rebreathing, especially if the oxygen flow rate is set at <5 L min−1 (to minimise aerosolisation). Rebreathing, together with hypoventilation from opioids and anaesthetics, may cause significant hypercarbia and should be avoided in COVID-19 patients with pneumonia and diminished respiratory reserves. It would be better to re-use the previously applied face mask (during preoxygenation), to conserve resources and avoid carbon dioxide rebreathing. After extubation, if required, low flow oxygen therapy via either a nasal cannula or a standard Hudson's mask can be administered, with a surgical mask placed over these devices to minimise viral transmission. There are limitations to the use of the plastic sheet that should be recognised, even though it is readily available, cost-effective, and easily applied. In conclusion, we concur with the use of a plastic sheet to limit droplet dispersion for aerosol-generating procedures in COVID-19 patients. However, careful consideration is needed in striking a balance between reducing environmental contamination and protecting healthcare workers, while simultaneously delivering safe care for patients.

Declarations of interest

The authors declare that they have no conflicts of interest.
  8 in total

1.  Consensus statement: Safe Airway Society principles of airway management and tracheal intubation specific to the COVID-19 adult patient group.

Authors:  David J Brewster; Nicholas Chrimes; Thy Bt Do; Kirstin Fraser; Christopher J Groombridge; Andy Higgs; Matthew J Humar; Timothy J Leeuwenburg; Steven McGloughlin; Fiona G Newman; Chris P Nickson; Adam Rehak; David Vokes; Jonathan J Gatward
Journal:  Med J Aust       Date:  2020-05-01       Impact factor: 7.738

Review 2.  Anaesthesia and COVID-19: infection control.

Authors:  Peter M Odor; Maximilian Neun; Sohail Bampoe; Sam Clark; Daniel Heaton; Emilie M Hoogenboom; Anil Patel; Michael Brown; Damon Kamming
Journal:  Br J Anaesth       Date:  2020-04-08       Impact factor: 9.166

3.  Extubation barrier drape to minimise droplet spread.

Authors:  Miguel Patino Montoya; Hovig V Chitilian
Journal:  Br J Anaesth       Date:  2020-04-11       Impact factor: 9.166

Review 4.  Reducing droplet spread during airway manipulation: lessons from the COVID-19 pandemic in Singapore.

Authors:  Phui S Au Yong; Xuanxuan Chen
Journal:  Br J Anaesth       Date:  2020-04-15       Impact factor: 9.166

Review 5.  Medications to reduce emergence coughing after general anaesthesia with tracheal intubation: a systematic review and network meta-analysis.

Authors:  Alan Tung; Nicholas A Fergusson; Nicole Ng; Vivien Hu; Colin Dormuth; Donald E G Griesdale
Journal:  Br J Anaesth       Date:  2020-02-22       Impact factor: 9.166

6.  Consensus guidelines for managing the airway in patients with COVID-19: Guidelines from the Difficult Airway Society, the Association of Anaesthetists the Intensive Care Society, the Faculty of Intensive Care Medicine and the Royal College of Anaesthetists.

Authors:  T M Cook; K El-Boghdadly; B McGuire; A F McNarry; A Patel; A Higgs
Journal:  Anaesthesia       Date:  2020-04-01       Impact factor: 6.955

7.  Emergency tracheal intubation in 202 patients with COVID-19 in Wuhan, China: lessons learnt and international expert recommendations.

Authors:  Wenlong Yao; Tingting Wang; Bailin Jiang; Feng Gao; Li Wang; Hongbo Zheng; Weimin Xiao; Shanglong Yao; Wei Mei; Xiangdong Chen; Ailin Luo; Liang Sun; Tim Cook; Elizabeth Behringer; Johannes M Huitink; David T Wong; Meghan Lane-Fall; Alistair F McNarry; Barry McGuire; Andrew Higgs; Amit Shah; Anil Patel; Mingzhang Zuo; Wuhua Ma; Zhanggang Xue; Li-Ming Zhang; Wenxian Li; Yong Wang; Carin Hagberg; Ellen P O'Sullivan; Lee A Fleisher; Huafeng Wei
Journal:  Br J Anaesth       Date:  2020-04-10       Impact factor: 11.719

8.  Clear plastic drapes may be effective at limiting aerosolization and droplet spray during extubation: implications for COVID-19.

Authors:  Clyde T Matava; Julie Yu; Simon Denning
Journal:  Can J Anaesth       Date:  2020-04-03       Impact factor: 6.713

  8 in total
  3 in total

Review 1.  One Year on: An Overview of Singapore's Response to COVID-19-What We Did, How We Fared, How We Can Move Forward.

Authors:  S Vivek Anand; Yao Kang Shuy; Poay Sian Sabrina Lee; Eng Sing Lee
Journal:  Int J Environ Res Public Health       Date:  2021-08-30       Impact factor: 4.614

2.  Mitigating the spread of COVID-19 during extubation: Assessing the impact of a barrier device.

Authors:  Robert W Simon
Journal:  Perioper Care Oper Room Manag       Date:  2022-09-30

Review 3.  Aerosol boxes and barrier enclosures for airway management in COVID-19 patients: a scoping review and narrative synthesis.

Authors:  Massimiliano Sorbello; William Rosenblatt; Ross Hofmeyr; Robert Greif; Felipe Urdaneta
Journal:  Br J Anaesth       Date:  2020-09-03       Impact factor: 9.166

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.