Literature DB >> 32410428

[Biomechanical comparative analysis of screw fixation and cortical endo-button fixation in Latarjet procedure for anterior dislocation of shoulder joint].

Daqiang Liang1, Shengzheng Kuai1, Ying Li1, Zhihe Qiu1, Sheng Li1, Bing Wu1, Mingjin Zhong1, Hao Li1, Haifeng Liu1, Wei Lu1.   

Abstract

OBJECTIVE: To clarify the value of the cortical endo-button as an internal fixator in Latarjet procedure through biomechanical analysis.
METHODS: Ten pairs of shoulder joints from 6-7 months old male pigs were selected. Each pair was randomly divided into screw group and endo-button group. A 25% glenoid defect model was created, and the porcine infraspinatus tendon and its associated bone were used to simulate conjoint tendon and coracoid process in human body. The bone grafts were fixed with two 3.5 mm screws and double cortical endo-buttons with high-strength sutures in screw group and endo-button group, respectively. The prepared glenoid defect model was fixed on a biomechanical test bench and optical markers were fixed on the glenoid and the bone block, respectively. Then fatigue test was performed to observe whether the graft or internal fixator would failed. During the test, the standard deviations of the relative displacement between the graft and the glenoid of two groups were measured by optical motion measure system for comparison. Finally the maximum failure load comparison was conducted and the maximum failure loads of the two groups were measured and compared.
RESULTS: There was no tendon tear, bone fracture, and other graft or internal fixation failure in the two groups during the fatigue test. The standard deviation of the relative displacement of the screw group was (0.007 87±0.001 44) mm, and that of the endo-button group was (0.034 88±0.011 10) mm, showing significant difference between the two groups ( t=7.682, P=0.000). The maximum failure load was (265±39) N in screw group and (275±52) N in endo-button group, showing no significant difference between the two groups ( t=1.386, P=0.199). There were 3 ways of failure: rupture at bone graft's tunnel (6/10 from screw group, 3/10 from endo-button group), tendon tear at the cramp (2/10 from screw group, 2/10 from endo-button group), and tendon tear at the internal fixator interface (2/10 from screw group, 5/10 from endo-button group), showing no significant difference between the two groups ( P=0.395).
CONCLUSION: Although the endo-button fixation fails to achieve the same strong fixation stability as the screw fixation, its fixation stability can achieve the clinical requirements. The two fixation methods can provide similar fixation strength when being used in Latarjet procedure.

Entities:  

Keywords:  Latarjet procedure; Shoulder joint instability; biomechanical test; endo-button fixation; screw fixation

Mesh:

Year:  2020        PMID: 32410428      PMCID: PMC8171848          DOI: 10.7507/1002-1892.201909124

Source DB:  PubMed          Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi        ISSN: 1002-1892


  17 in total

1.  [Treatment of recurrent dislocation of the shoulder].

Authors:  M LATARJET
Journal:  Lyon Chir       Date:  1954 Nov-Dec

Review 2.  Complications associated with open coracoid transfer procedures for shoulder instability.

Authors:  Usman Butt; Charalambos P Charalambous
Journal:  J Shoulder Elbow Surg       Date:  2012-05-18       Impact factor: 3.019

3.  Biomechanical comparison of the Latarjet procedure with and without a coracoid bone block.

Authors:  W Barrett Payne; Matthew T Kleiner; Michelle H McGarry; James E Tibone; Thay Q Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-12-12       Impact factor: 4.342

4.  Anatomic and Biomechanical Comparison of the Classic and Congruent-Arc Techniques of the Latarjet Procedure.

Authors:  Scott R Montgomery; J Christoph Katthagen; Jacob D Mikula; Daniel Cole Marchetti; Dimitri S Tahal; Grant J Dornan; Kimi D Dahl; Alex W Brady; Travis Lee Turnbull; Peter J Millett
Journal:  Am J Sports Med       Date:  2017-02-14       Impact factor: 6.202

5.  Coracoid bone block fixation with cortical buttons: An alternative to screw fixation?

Authors:  P Gendre; C-E Thélu; T d'Ollonne; C Trojani; J-F Gonzalez; P Boileau
Journal:  Orthop Traumatol Surg Res       Date:  2016-10-05       Impact factor: 2.256

Review 6.  Complications and re-operations after Bristow-Latarjet shoulder stabilization: a systematic review.

Authors:  Michael J Griesser; Joshua D Harris; Brett W McCoy; Waqas M Hussain; Morgan H Jones; Julie Y Bishop; Anthony Miniaci
Journal:  J Shoulder Elbow Surg       Date:  2013-02       Impact factor: 3.019

7.  Biomechanical comparison of intramedullary cortical button fixation and interference screw technique for subpectoral biceps tenodesis.

Authors:  Arne Buchholz; Frank Martetschläger; Sebastian Siebenlist; Gunther H Sandmann; Alexander Hapfelmeier; Andreas Lenich; Peter J Millett; Ulrich Stöckle; Florian Elser
Journal:  Arthroscopy       Date:  2013-03-07       Impact factor: 4.772

8.  Does the dynamic sling effect of the Latarjet procedure improve shoulder stability? A biomechanical evaluation.

Authors:  Joshua W Giles; Harm W Boons; Ilia Elkinson; Kenneth J Faber; Louis M Ferreira; James A Johnson; George S Athwal
Journal:  J Shoulder Elbow Surg       Date:  2012-09-28       Impact factor: 3.019

Review 9.  Latarjet, Bristow, and Eden-Hybinette procedures for anterior shoulder dislocation: systematic review and quantitative synthesis of the literature.

Authors:  Umile Giuseppe Longo; Mattia Loppini; Giacomo Rizzello; Mauro Ciuffreda; Nicola Maffulli; Vincenzo Denaro
Journal:  Arthroscopy       Date:  2014-06-04       Impact factor: 4.772

10.  Bankart lesion repair: biomechanical and anatomical analysis of Mason-Allen and simple sutures in a swine model.

Authors:  Ricardo Barreto Monteiro Dos Santos; Cleber Maciel de Morais Prazeres; Ricardo Mertens Fittipaldi; João Monteiro Neto; Tiago Cerqueira Lima Nogueira; Saulo Monteiro Dos Santos
Journal:  Rev Bras Ortop       Date:  2018-06-12
View more
  1 in total

1.  [Analysis of influencing factors of early pain after arthroscopic rotator cuff repair].

Authors:  Dongfang Zhang; Fengkun Wang; Guodong Yang; Jia Guo; Yingze Zhang; Tengbo Yu; Yuerong Sun; Chao Qi
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2022-03-15
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.