| Literature DB >> 32407826 |
Songjie Wu1, Ying Wang2, Xuelan Jin1, Jia Tian1, Jianzhong Liu3, Yiping Mao4.
Abstract
BACKGROUND: Coronavirus disease 2019 (COVID-19) is characterized by risk of nosocomial transmission; however, the extent of environmental contamination and its potential contribution of environmental contamination to SARS-CoV-2 transmission are poorly understood. This study aimed to investigate whether environmental contamination may play a role in SARS-CoV-2 transmission.Entities:
Keywords: Air; Disinfection; Environmental surface; Hand hygiene; Hospital-associated infection
Mesh:
Year: 2020 PMID: 32407826 PMCID: PMC7214329 DOI: 10.1016/j.ajic.2020.05.003
Source DB: PubMed Journal: Am J Infect Control ISSN: 0196-6553 Impact factor: 2.918
Fig 1Room layout of the general isolation ward 1 and the living quarters showing environmental and air sampling sites. Numbered labels correspond to environmental sampling sites. ① beepers; ② bed rails; ③ desktops;④ bedside tables;⑤ oxygen cylinder valve;⑥ medical equipment such as ventilator, monitors, and X-ray devices, etc;⑦ door handles;⑧ elevator buttons;⑨ keyboards;⑩ computer mouses;⑪ telephones; ⑫ water machine buttons; A refers to air samples. The medical area with moderate and high risk contains patient's room, nurses station, buffer room for taking off PPE, and elevator; the living quarters with low risk contains the rest rooms, office area, and buffer room for taking on PPE.
Positive rate of air samples from different departments in medical areas
| Areas | NO.of tests | NO.of Positive | Positive rate (%) |
|---|---|---|---|
| General isolation wards | 13 | 0 | 0.00 |
| Ward 1 | 3 | 0 | 0.00 |
| Ward 2 | 3 | 0 | 0.00 |
| Ward 3 | 1 | 0 | 0.00 |
| Ward 4 | 2 | 0 | 0.00 |
| Ward 5 | 3 | 0 | 0.00 |
| Ward 6 | 1 | 0 | 0.00 |
| Intensive care units | 13 | 0 | 0.00 |
| Fever clinic | 18 | 0 | 0.00 |
| Emergency room | 3 | 0 | 0.00 |
| Observation room | 1 | 0 | 0.00 |
| Treatment room | 1 | 0 | 0.00 |
| Infusion room | 1 | 0 | 0.00 |
| Diagnosis room 1 | 2 | 0 | 0.00 |
| Diagnosis room 2 | 2 | 0 | 0.00 |
| Throat swab sampling room | 2 | 0 | 0.00 |
| Public area | 6 | 0 | 0.00 |
| Total | 44 | 0 | 0.00 |
Positive rate of samples from environmental surface in different areas
| Areas | No. of tests | No. of positive | Positive rate (%) |
|---|---|---|---|
| Medical areas | 145 | 36 | 24.83 |
| General isolation ward | 72 | 18 | 25.00 |
| Ward 1 | 12 | 6 | 50.00 |
| Ward 2 | 12 | 0 | 0.00 |
| Ward 3 | 12 | 4 | 33.33 |
| Ward 4 | 12 | 3 | 25.00 |
| Ward 5 | 12 | 1 | 8.33 |
| Ward 6 | 12 | 4 | 33.33 |
| Intensive care units | 24 | 9 | 37.50 |
| Clinical laboratory | 7 | 0 | 0.00 |
| Fever clinic | 42 | 9 | 21.43 |
| Emergency room | 12 | 6 | 50.00 |
| Observation room | 4 | 1 | 25.00 |
| Treatment room | 4 | 0 | 0.00 |
| Infusion room | 4 | 0 | 0.00 |
| Diagnosis room 1 | 4 | 1 | 25.00 |
| Diagnosis room 2 | 4 | 0 | 0.00 |
| Throat swab sampling room | 8 | 0 | 0.00 |
| Public area | 2 | 1 | 50.00 |
| Living quarters | 55 | 2 | 3.64 |
| Office area | 22 | 2 | 9.09 |
| Rest room | 33 | 0 | 0.00 |
| Total | 200 | 38 | 19.00 |
Positive rate of samples from environmental surface of specific sites in medical areas
| Sampling site | No. of tests | No. of positivity | Positive rate (%) |
|---|---|---|---|
| Beepers | 6 | 3 | 50.00 |
| Water machine buttons | 8 | 4 | 50.00 |
| Elevator buttons | 7 | 3 | 42.86 |
| Computer mouses | 10 | 4 | 40.00 |
| Telephones | 10 | 4 | 40.00 |
| Keyboards | 15 | 5 | 33.33 |
| Medical equipment | 13 | 4 | 30.77 |
| Oxygen cylinder valve | 8 | 2 | 25.00 |
| Desktops | 18 | 3 | 16.67 |
| Bedrails | 7 | 1 | 14.29 |
| Bedside tables | 7 | 1 | 14.29 |
| Gloves | 7 | 1 | 14.29 |
| Door handles | 15 | 0 | 0.00 |
| Others | 14 | 1 | 7.14 |
| Total | 145 | 36 | 24.83 |