Literature DB >> 32406263

Comparison of Robotic Percutaneous Coronary Intervention With Traditional Percutaneous Coronary Intervention: A Propensity Score-Matched Analysis of a Large Cohort.

Tejas M Patel1, Sanjay C Shah1, Yash Y Soni1, Rajni C Radadiya1, Gaurav A Patel2, Pradyot O Tiwari1, Samir B Pancholy2.   

Abstract

BACKGROUND: Robotic percutaneous coronary intervention (R-PCI) has been shown to benefit the operator but has not shown any significant benefit to the patient. We sought to compare a large cohort of R-PCI to traditional percutaneous coronary intervention (PCI) procedures performed at a tertiary care center in the same time frame.
METHODS: A total of 996 consecutive patients referred for PCI between December 2017 and March 2019 were studied, of which 310 (31.1%) patients were selected to undergo R-PCI and 686 (68.9%) patients underwent traditional PCI. The coprimary study outcome measures were air kerma, dose-area product, fluoroscopy time, volume of contrast, and total procedural time. Caliper propensity-matching technique was used (caliper, 0.05) to match each R-PCI patient to the nearest traditional PCI patient without replacement.
RESULTS: Air kerma (mGy; median [interquartile range]; P; 884 [537-1398] versus 1110 [699-1498]; P=0.002) and dose-area product (cGycm2; 4734 [2695-7746] versus 5746 [3751-7833]; P=0.003) were significantly lower in the R-PCI group. There was no difference in fluoroscopy time (minutes; 5.51 [3.53-8.31] versus 5.48 [3.31-9.37]; P=0.936) and contrast volume (mL; 130 [103-170] versus 140 [100-180]; P=0.905). Total procedural time (minutes) was significantly higher in the R-PCI group (27 [21-40] versus 37 [27-50]; P<0.0005).
CONCLUSIONS: R-PCI is associated with a significant decrease in radiation exposure to the patient with no increase in fluoroscopy time, as well as contrast utilization, and a minor increase in procedure duration compared with traditional PCI.

Entities:  

Keywords:  cohort studies; fluoroscopy; percutaneous coronary intervention; robotic surgical procedures; tertiary care centers

Year:  2020        PMID: 32406263     DOI: 10.1161/CIRCINTERVENTIONS.119.008888

Source DB:  PubMed          Journal:  Circ Cardiovasc Interv        ISSN: 1941-7640            Impact factor:   6.546


  10 in total

Review 1.  A contemporary review of clinical significances of percutaneous coronary intervention for chronic total occlusions, with some Japanese insights.

Authors:  Yoshihiro Morino
Journal:  Cardiovasc Interv Ther       Date:  2021-03-03

2.  Robotics for neuroendovascular intervention: Background and primer.

Authors:  Kazim H Narsinh; Ricardo Paez; Kerstin Mueller; M Travis Caton; Amanda Baker; Randall T Higashida; Van V Halbach; Christopher F Dowd; Matthew R Amans; Steven W Hetts; Alexander M Norbash; Daniel L Cooke
Journal:  Neuroradiol J       Date:  2021-08-16

3.  A decade retrospective of medical robotics research from 2010 to 2020.

Authors:  Pierre E Dupont; Bradley J Nelson; Michael Goldfarb; Blake Hannaford; Arianna Menciassi; Marcia K O'Malley; Nabil Simaan; Pietro Valdastri; Guang-Zhong Yang
Journal:  Sci Robot       Date:  2021-11-10

Review 4.  Robotic-assisted percutaneous coronary intervention in the COVID-19 pandemic.

Authors:  Kazunori Yamaji; Yoshiaki Mitsutake; Masaharu Nakano; Takuya Nakamura; Yoshihiro Fukumoto
Journal:  J Cardiol       Date:  2021-08-19       Impact factor: 3.159

5.  Kinetics Analysis and ADRC-Based Controller for a String-Driven Vascular Intervention Surgical Robotic System.

Authors:  Wei Zhou; Shuxiang Guo; Jin Guo; Zhengyang Chen; Fanxu Meng
Journal:  Micromachines (Basel)       Date:  2022-05-13       Impact factor: 3.523

Review 6.  A Review of Robotic Interventional Neuroradiology.

Authors:  C B Beaman; N Kaneko; P M Meyers; S Tateshima
Journal:  AJNR Am J Neuroradiol       Date:  2021-02-04       Impact factor: 4.966

7.  Successful introduction of robotic-assisted percutaneous coronary intervention system into Japanese clinical practice: a first-year survey at single center.

Authors:  Kotaro Kagiyama; Yoshiaki Mitsutake; Takafumi Ueno; Shinji Sakai; Takuya Nakamura; Kazunori Yamaji; Takashi Ishimatsu; Masahiro Sasaki; Hidetoshi Chibana; Naoki Itaya; Ken-Ichiro Sasaki; Yoshihiro Fukumoto
Journal:  Heart Vessels       Date:  2021-01-27       Impact factor: 2.037

8.  Dethroning Contrast Angiography: A Place for Electroanatomic Mapping?

Authors:  Neal S Kleiman
Journal:  JACC Basic Transl Sci       Date:  2022-02-28

9.  Futuristic robotic percutaneous coronary intervention with innovative physiology optimization: a case report.

Authors:  Yerramareddy Vijayachandra; Shalini Mani
Journal:  Eur Heart J Case Rep       Date:  2022-07-01

10.  ADRC-Based Control Method for the Vascular Intervention Master-Slave Surgical Robotic System.

Authors:  Wei Zhou; Shuxiang Guo; Jin Guo; Fanxu Meng; Zhengyang Chen
Journal:  Micromachines (Basel)       Date:  2021-11-25       Impact factor: 2.891

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.