A Best-Fit of an Anatomic Tibial Baseplate Closely Parallels the Flexion-Extension Plane and Covers a High Percentage of the Proximal Tibia.

Alexander J Nedopil1, Tomas Zamora2, Trevor Shelton3, Stephen M Howell4, Maury Hull3,5,6.   

Abstract

There are no reports of in vivo internal-external (I-E) rotational alignment and coverage of the proximal tibia after performing a best-fit method of an anatomically designed and asymmetrically shaped tibial baseplate during calipered kinematically aligned (KA) total knee arthroplasty (TKA). We hypothesized that a best-fit plane sets the anterior-posterior (A-P) axis of the anatomic baseplate closely parallel to the flexion-extension (F-E) plane of the knee and covers a high percentage of the proximal tibia. A total of 145 consecutive primary TKAs were prospectively collected. The calipered KA method and verification checks set the positions and orientations of the components without ligament release in all knees without restrictions on the preoperative deformities. A best-fit method selected one of six trials of anatomic baseplates that maximized coverage and set I-E rotation parallel to and within the cortical edge of the proximal tibia. The angle between the transverse axes of the components (i.e., the deviation of the A-P axis of the anatomic baseplate from the F-E plane of the native knee) and the cross-sectional area (CSA) of the proximal tibia were measured on postoperative computerized tomographic scans. The mean deviation of the anatomic baseplate from the F-E plane was 2-degree external ± 5 degrees. The mean coverage of the proximal tibia was 87 ± 6% (CSA of baseplate from the manufacturer/CSA of proximal tibia × 100). The anatomic baseplate and best-fit method adequately set I-E rotation of the baseplate closely parallel to the F-E plane of the knee and cover a high percentage of the proximal tibia. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Entities:  

Year:  2020        PMID: 32403149     DOI: 10.1055/s-0040-1710367

Source DB:  PubMed          Journal:  J Knee Surg        ISSN: 1538-8506            Impact factor:   2.757


  3 in total

1.  Low tibial baseplate migration 1 year after unrestricted kinematically aligned total knee arthroplasty using a medial conforming implant design.

Authors:  Abigail E Niesen; Anna L Garverick; Stephen M Howell; Maury L Hull
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2022-10-06       Impact factor: 4.114

2.  A TKA Insert with A Lateral Flat Articular Surface Maximizes External and Internal Tibial Orientations without Anterior Lift-Off Relative to Low- and Ultracongruent Surfaces.

Authors:  Alexander J Nedopil; Stephen M Howell; Maury L Hull
Journal:  J Pers Med       Date:  2022-08-03

3.  An insert with less than spherical medial conformity causes a loss of passive internal rotation after calipered kinematically aligned TKA.

Authors:  Alexander J Nedopil; Adithya Shekhar; Stephen M Howell; Maury L Hull
Journal:  Arch Orthop Trauma Surg       Date:  2021-07-15       Impact factor: 3.067

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.