Literature DB >> 32386354

Can dried blood spots (DBS) contribute to conducting comprehensive SARS-CoV-2 antibody tests?

Mario Thevis1,2, Andre Knoop1, Maximilian S Schaefer3,4, Bertin Dufaux5, Yvonne Schrader1, Andreas Thomas1, Hans Geyer1,2.   

Abstract

Entities:  

Mesh:

Substances:

Year:  2020        PMID: 32386354      PMCID: PMC7272963          DOI: 10.1002/dta.2816

Source DB:  PubMed          Journal:  Drug Test Anal        ISSN: 1942-7603            Impact factor:   3.234


× No keyword cloud information.

INTRODUCTION

Within months of the first report on its outbreak, the extent of the pandemic caused by the severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) has reached unexpected dimensions, and despite enormous global scientific efforts, several aspects characterizing the coronavirus disease 2019 (COVID‐19) and its transmission are not yet fully understood. , , A common credo amongst scientists appears to be the fact that analytical diagnostics are vital for understanding and, eventually, managing the pandemic. Here, complementary tests based on real‐time quantitative polymerase chain reaction (RT‐qPCR) analyses targeting the single‐stranded RNA‐composed virus and immunological approaches monitoring the development of immune responses of infected (and recovered) individuals have been established. , Advantages and limitations exist with both strategies, and various factors are suspected to affect the reliability of the analytical result; yet, diagnostics are indispensable, and comprehensiveness and testing frequency is considered to be of particular importance in supporting the confinement of the pandemic. , An option to facilitate the testing of different anti‐SARS‐CoV‐2 antibodies could be the extension of existing analytical platforms from conventionally collected venous blood samples (including whole blood, serum, and plasma) to minimally invasive sampled capillary blood such as dried blood spots (DBS) or dried plasma spots (DPS), in line with recent initiatives, for example, by the US National Institutes of Health (NIH) or the Royal Institute of Technology Stockholm, Sweden, as well as earlier investigations into targeting anti‐influenza IgG antibodies. Different versions of DBS and DPS collection kits are commercially available and are frequently employed in different areas of drug monitoring and testing. , , Sampling can be performed by individuals without the need for medical professionals, samples can be shipped to the test facility by regular mail services to be subjected to routine serology, large numbers of specimens can be obtained in short time periods supporting the testing of cohorts of substantial extent, and lastly dry test material appears to exhibit reduced infectivity , , and increased target analyte stability.

PROOF‐OF‐PRINCIPLE PILOT STUDY ‐ EXPERIMENTAL

Most currently available tests designed for the detection of SARS‐CoV‐2 antibodies are approved for serum, plasma, and/or whole blood, whilst protocols for the use/application of DBS or DPS are not yet available. A proof‐of‐principle pilot study was conducted to probe for options as to how routine sports drug testing programs can contribute to generating information on the prevalence of SARS‐CoV‐2 antibodies in a sub‐population of elite athletes. As DBS tests have been studied in the context of general doping controls extensively over the past decade, , , , , , , , , , the applicability of two commercially available IgG and IgM tests, one‐well plate ELISA assay, and one lateral flow‐based rapid test, to the analysis of paired DBS and blood plasma samples obtained from 26 individuals was assessed. With approval of the local ethics committee (#054/2020, German Sport University Cologne, Germany) and written informed consent of the participants, volumes of 20 μL of capillary blood (fingerprick) per specimen were used to collect DBS on two different supports including cellulose‐based DBS cards (Whatman FTA DMPK‐C, VWR Darmstadt, Germany) and a microsampling device featuring a hydrophilic porous material tip (10 μL Mitra sampler, Neoteryx, Maastricht, The Netherlands). DBS were dried at room temperature for 2 h and then stored in a plastic bag in the presence of 0.5 g desiccant sachets until analysis. Further, a single sample of venous blood was collected into 4 mL K2EDTA (1.8 mg/mL) or SST II Advance tubes (both BD Vacutainer, BD Heidelberg, Germany) from each participant. The plasma/serum was separated by centrifugation (20 min at 1300 rpm) within 4 h post collection and stored at +4°C until assayed. Overall, the pilot study cohort was composed of 18 men and 8 women, age range 28–64 years, 21 of which underwent prior SARS‐CoV‐2 PCR tests yielding 16 positive results (Table 1). Study participants were either returnees from regions severely affected by the COVID‐19 pandemic or had been in close contact to infected individuals.
TABLE 1

Summary of pilot study participant information and comparison of antibody test results using a lateral‐flow test device and a microtiter well‐plate ELISA employing plasma, serum, and DBS as test matrices. Positive test results are illustrated in green, negative findings in red, and suspicious results are shown in white [Colour table can be viewed at wileyonlinelibrary.com]

RayBiotech lateral‐flow testEDI ELISA test
ParticipantSexPCR testSeverity of symptoms * Plasma IgGDBS IgGPlasma IgMDBS IgMPlasma IgGDBS IgGPlasma IgMDBS IgM
1fYes/pos7 Pos Pos Pos Pos Pos a Pos b Pos Pos b
2mYes/pos4 Pos Pos Pos Pos Pos a Pos b Pos Pos b
3fYes/pos6 Pos Pos Pos Pos Pos a Pos b Pos Pos b
4fYes/pos5 Pos Pos Pos Pos Pos Pos Pos Neg
5mYes/pos2 Neg Neg Neg Neg Neg Neg Neg Neg
6fYes/pos6 Pos Pos Pos Pos Pos Pos Neg Neg
7mYes/pos10 Pos Pos Pos Pos Pos Pos Neg Neg
8mYes/posn.p. Neg Neg Neg Neg Neg Neg Neg Neg
9mYes/pos4 Pos Pos Pos Pos Pos Pos Pos Pos
10mYes/pos8 Pos Pos Pos Pos Pos Pos Pos Pos
11mYes/pos5 Pos Pos Pos Pos Pos Pos Pos Pos
12fYes/pos7 Pos Pos Pos Pos Pos Pos Neg Neg
13mYes/pos4 Pos Pos Pos Pos Pos Pos Neg Neg
14mYes/pos6 Pos Pos Pos Neg Pos Pos Pos Neg
15mYes/pos1 Pos Pos Pos Pos Pos Pos Pos Pos
16mYes/posn.p. Pos Pos Pos Neg Pos Pos Neg Pos
17mYes/neg1 Pos Pos Pos Pos Pos Pos Neg Neg
18mYes/neg0 Pos Pos Pos Pos Pos Pos Pos Pos
19mYes/neg9 Pos Pos Pos Pos Pos Pos Neg Neg
20fYes/neg5 Neg Neg Neg Neg Neg Neg Neg Neg
21mYes/neg1 Pos Pos Pos Pos Pos Pos Pos Pos
22mNo0SusSus Pos Pos Neg Neg Neg Neg
23mNo0 Pos Pos Pos Pos Pos a Pos b Pos Pos b
24mNo0 Neg Neg Neg Neg Neg Neg Neg Neg
25fNo0 Pos Pos Pos Pos Pos Pos Neg Pos
26fNo3 Neg Neg Neg Neg Neg Neg Neg Neg

Identical result in corresponding serum sample.

Identical result in corresponding Mitra sample.

Self‐reported on a numeric rating scale from 0 (no symptoms) to 10 (worst symptoms imaginable) /n.p. = not provided.

Summary of pilot study participant information and comparison of antibody test results using a lateral‐flow test device and a microtiter well‐plate ELISA employing plasma, serum, and DBS as test matrices. Positive test results are illustrated in green, negative findings in red, and suspicious results are shown in white [Colour table can be viewed at wileyonlinelibrary.com] Identical result in corresponding serum sample. Identical result in corresponding Mitra sample. Self‐reported on a numeric rating scale from 0 (no symptoms) to 10 (worst symptoms imaginable) /n.p. = not provided. The lateral‐flow RayBiotech SARS‐CoV‐2 IgM and IgG rapid test kits were obtained from Hölzel Diagnostics (Cologne, Germany), while the Epitope Diagnostics EDI Novel Coronavirus COVID‐19 ELISA Kits KT‐1032 and KT‐1033 (for IgG and IgM analysis) were purchased from Immundiagnostik AG (Bensheim, Germany). Plasma samples were prepared in accordance with the manufacturers’ protocols for analysis using the respective test kits. Of note, deviating information existed as to the compatibility of the EDI ELISA with plasma; while the manufacturer lists serum only as the test matrix, the distributor mentioned plasma also as an applicable specimen. Hence, for a subset of four participants, both serum and plasma were tested for IgGs. DBS were prepared for IgG and IgM analysis by extraction into an aqueous EDTA solution (1.35 mg/mL). Therefore, entire spots were punched from DBS cards and cut into eighths, while the absorbent material from the Mitra tips was merely removed from the plastic support. The test materials were then placed into polypropylene tubes (2 mL), fortified with 100 μL of aqueous EDTA, and ultrasonicated for 10 min. Following a 1 min spin‐down at 625 × g, 25 μL of the extract was subjected to RayBiotech analysis. For EDI ELISA analysis, IgG measurements were conducted by mixing 20 μL of the extract with 200 μL EDI ELISA assay diluent before processing further according to the recommended protocols. IgM analyses were performed with 25 μL of the DBS extract, which was placed in the microtiter well plate before adding 75 μL of the provided diluent and further processing of the test kit as described by the manufacturer.

PROOF‐OF‐PRINCIPLE PILOT STUDY – RESULTS AND DISCUSSION

The goal of this pilot study was to probe for the potential of obtaining comparable results when testing conventional serum or plasma samples and DBS for anti‐SARS‐CoV‐2 antibodies with commercially available test kits as a means to substantially and rapidly expand laboratory‐based testing options. If successful and robust, two beneficial aspects can be combined: On the one hand, test samples can be obtained quickly and without the necessity of medically trained personnel for the sampling procedure, supporting optimized assignments of available resources especially during epidemic/pandemic crises. On the other hand, performing the actual test and interpreting the analytical result in controlled working conditions and by expert personnel in analytical laboratories contributes to obtaining the best possible test results. Sample preparation strategies for DBS analyses were obtained by adapting the assay manufacturers’ protocols and assessing the effect of modifying parameters such as the blood volume used to produce DBS (5–20 μL), the duration of ultrasonication (10–60 min), and sample/buffer dilution ratios. While the blood volume resulting in DBS and dilution factors were found to be critical to reaching test results similar to those obtained from plasma and serum analyses with the considered assays, prolonged extraction periods were not found to affect the comparability of the test results. In Table 1, the test results from paired plasma/serum and DBS tests are presented, demonstrating the principle applicability of DBS to the chosen commercial anti‐SARS‐CoV‐2 antibody assays when applying moderate modifications to sample preparation protocols. IgG analyses consistently yielded identical test results using both the lateral‐flow and the ELISA test kits with paired matches (positive, negative, and overall rate of agreement 100%, κ = 1.0 [95% CI 1.0; 1.0] Table 1). With the EDI ELISA assay, all results above the assay‐defined cut‐off were considered as “positive” and all below as “negative”; in the case of the lateral‐flow test device, the absence of bands was recorded as “negative”, shadowy bands were documented as “suspicious”, and clear bands as “positive”. Overall, the tested cohort yielded 20 positive, five negative, and one suspicious lateral‐flow test results, and 20 positive and 6 negative test results were obtained using the EDI ELISA. A total of four additional serum samples was analyzed under identical conditions to their corresponding plasma samples, confirming the results obtained therein (indicated in Table 1 with a superscript “a”). For IgM, less comparable yet good results were obtained, with 24 out of 26 (lateral‐flow test) and 22 out of 26 (ELISA) DBS‐borne results matching the corresponding plasma‐derived findings (lateral‐flow: 100% positive, 71.4% negative and 92.3% overall rate of agreement, κ = 0.79 [95% CI 0.51; 1.00); ELISA: 83.3% positive, 85.7% negative and 84.6% overall rate of agreement, κ = 0.69 [95% CI 0.41; 0.97]). Here, in two cases of lateral‐flow assay analyses, DBS samples returned negative results where the plasma analysis result was interpreted as positive. The four failing pairs of the EDI ELISA consisted of two scenarios where DBS were negative and plasma positive and vice versa. These discrepancies were observed also when the tests were repeated, and further sample preparation optimization might be required to reduce the probability of deviating test results.

CONCLUSIONS

In addition to serum, plasma, and fresh whole blood, dried blood spots appear to represent a viable complement to routine anti‐SARS‐CoV‐2 antibody test matrices. DBS facilitate the collection and processing of significant numbers of test samples, supporting the generation of data critical to developing and applying epidemiological models on the presumably undetected spread of infections. International initiatives have recently been launched, , developing DBS‐based testing approaches to exploit the substantial advantages associated with dried test matrices collected by individuals without the need of medical supervision. In order to provide diagnostic values equivalent to serum or plasma samples, the compatibility of test assays with extracts from DBS (including potentially required adaptations of sample pretreatment protocols) has to be thoroughly assessed or, alternatively, assays specified (amongst other matrices) for DBS analyses have to be established and characterized. Also, follow‐up studies with larger cohorts than the herein presented pilot study group with a remarkably high prevalence of COVID‐19 are required, and further specifics of SARS‐CoV‐2 analyses from DBS need to be examined concerning, for example, longer‐term analyte stability.

FUNDING INFORMATION

Federal Ministry of the Interior, Building and Community (Berlin, Germany) and the Manfred‐Donike‐Institute for Doping Analysis (Cologne, Germany).
  21 in total

1.  Quantitative determination of opioids in whole blood using fully automated dried blood spot desorption coupled to on-line SPE-LC-MS/MS.

Authors:  Ruth Verplaetse; Jack Henion
Journal:  Drug Test Anal       Date:  2015-11-26       Impact factor: 3.345

2.  Detection of erythropoiesis-stimulating agents in a single dried blood spot.

Authors:  Gemma Reverter-Branchat; Rosa Ventura; Mohammed Ezzel Din; Julián Mateus; Carme Pedro; Jordi Segura
Journal:  Drug Test Anal       Date:  2018-07-05       Impact factor: 3.345

3.  Serological Assays for SARS-CoV-2 Infectious Disease: Benefits, Limitations and Perspectives.

Authors:  Maria Infantino; Arianna Damiani; Francesca Li Gobbi; Valentina Grossi; Barbara Lari; Donatella Macchia; Patrizia Casprini; Francesca Veneziani; Danilo Villalta; Nicola Bizzaro; Piero Cappelletti; Martina Fabris; Luca Quartuccio; Maurizio Benucci; Mariangela Manfredi
Journal:  Isr Med Assoc J       Date:  2020-04       Impact factor: 0.892

4.  Detection of autologous blood transfusions using a novel dried blood spot method.

Authors:  Holly D Cox; Geoffrey D Miller; Auriella Lai; Dan Cushman; Daniel Eichner
Journal:  Drug Test Anal       Date:  2017-11-27       Impact factor: 3.345

Review 5.  2019 novel coronavirus: an emerging global threat.

Authors:  Cristie Columbus; Karen B Brust; Alejandro C Arroliga
Journal:  Proc (Bayl Univ Med Cent)       Date:  2020-02-26

Review 6.  Spot them in the spot: analysis of abused substances using dried blood spots.

Authors:  Nele Sadones; Sara Capiau; Pieter M M De Kesel; Willy E Lambert; Christophe P Stove
Journal:  Bioanalysis       Date:  2014-08       Impact factor: 2.681

Review 7.  Persistence of coronaviruses on inanimate surfaces and their inactivation with biocidal agents.

Authors:  G Kampf; D Todt; S Pfaender; E Steinmann
Journal:  J Hosp Infect       Date:  2020-02-06       Impact factor: 3.926

Review 8.  One month of the novel coronavirus 2019 outbreak: Is it still a threat?

Authors:  Apu Chowdhury; Nabila Jahan; Sicen Wang
Journal:  Virusdisease       Date:  2020-04-20

9.  Evaluation of the auxiliary diagnostic value of antibody assays for the detection of novel coronavirus (SARS-CoV-2).

Authors:  Gao Yong; Yuan Yi; Li Tuantuan; Wang Xiaowu; Li Xiuyong; Li Ang; Han Mingfeng
Journal:  J Med Virol       Date:  2020-07-11       Impact factor: 20.693

10.  Application of volumetric absorptive microsampling (VAMS) to measure multidimensional anti-influenza IgG antibodies by the mPlex-Flu assay.

Authors:  Jiong Wang; Dongmei Li; Alexander Wiltse; Jason Emo; Shannon P Hilchey; Martin S Zand
Journal:  J Clin Transl Sci       Date:  2019-09-26
View more
  10 in total

1.  Serological surveys to estimate cumulative incidence of SARS-CoV-2 infection in adults (Sero-MAss study), Massachusetts, July-August 2020: a mail-based cross-sectional study.

Authors:  Teah Snyder; Johanna Ravenhurst; Estee Y Cramer; Nicholas G Reich; Laura Balzer; Dominique Alfandari; Andrew A Lover
Journal:  BMJ Open       Date:  2021-08-17       Impact factor: 3.006

2.  A high-throughput microfluidic nanoimmunoassay for detecting anti-SARS-CoV-2 antibodies in serum or ultralow-volume blood samples.

Authors:  Zoe Swank; Grégoire Michielin; Hon Ming Yip; Patrick Cohen; Diego O Andrey; Nicolas Vuilleumier; Laurent Kaiser; Isabella Eckerle; Benjamin Meyer; Sebastian J Maerkl
Journal:  Proc Natl Acad Sci U S A       Date:  2021-05-04       Impact factor: 11.205

3.  Detection of anti-SARS-CoV-2 antibodies in dried blood spots utilizing manual or automated spot extraction and electrochemiluminescence immunoassay (ECLIA).

Authors:  Andre Knoop; Hans Geyer; Oliver Lerch; Ana Rubio; Yvonne Schrader; Mario Thevis
Journal:  Anal Sci Adv       Date:  2021-03-26

4.  Analysis of SARS-CoV-2 antibodies from dried blood spot samples with the Roche Elecsys Immunochemistry method.

Authors:  Elizabeth Fontaine; Cristian Saez
Journal:  Pract Lab Med       Date:  2021-04-28

5.  Development of Certified Reference Material for Amino Acids in Dried Blood Spots and Accuracy Assessment of Disc Sampling.

Authors:  Sangji Woo; Nordiana Rosli; Seohyun Choi; Ha-Jeong Kwon; Young Ahn Yoon; Sunhyun Ahn; Ji Youn Lee; Seon-Pyo Hong; Ji-Seon Jeong
Journal:  Anal Chem       Date:  2022-07-08       Impact factor: 8.008

6.  Development and validation of a quantitative, non-invasive, highly sensitive and specific, electrochemical assay for anti-SARS-CoV-2 IgG antibodies in saliva.

Authors:  Samantha H Chiang; Michael Tu; Jordan Cheng; Fang Wei; Feng Li; David Chia; Omai Garner; Sukantha Chandrasekaran; Richard Bender; Charles M Strom; David T W Wong
Journal:  PLoS One       Date:  2021-07-01       Impact factor: 3.240

7.  Evaluation of Dried Blood Spot Testing for SARS-CoV-2 Serology Using a Quantitative Commercial Assay.

Authors:  Davor Brinc; Mia J Biondi; Daniel Li; Heng Sun; Camelia Capraru; David Smookler; Muhammad Atif Zahoor; Julia Casey; Vathany Kulasingam; Jordan J Feld
Journal:  Viruses       Date:  2021-05-22       Impact factor: 5.048

8.  Can dried blood spots (DBS) contribute to conducting comprehensive SARS-CoV-2 antibody tests?

Authors:  Mario Thevis; Andre Knoop; Maximilian S Schaefer; Bertin Dufaux; Yvonne Schrader; Andreas Thomas; Hans Geyer
Journal:  Drug Test Anal       Date:  2020-06-18       Impact factor: 3.234

9.  Sensitive Detection of SARS-CoV-2-Specific Antibodies in Dried Blood Spot Samples.

Authors:  Gabriella L Morley; Stephen Taylor; Sian Jossi; Marisol Perez-Toledo; Sian E Faustini; Edith Marcial-Juarez; Adrian M Shields; Margaret Goodall; Joel D Allen; Yasunori Watanabe; Maddy L Newby; Max Crispin; Mark T Drayson; Adam F Cunningham; Alex G Richter; Matthew K O'Shea
Journal:  Emerg Infect Dis       Date:  2020-09-24       Impact factor: 6.883

10.  Simple, sensitive, specific self-sampling assay secures SARS-CoV-2 antibody signals in sero-prevalence and post-vaccine studies.

Authors:  Maryam Khan; Carolina Rosadas; Ksenia Katsanovskaja; Isaac D Weber; Justin Shute; Samreen Ijaz; Federica Marchesin; Eleanor McClure; Salem Elias; Barnaby Flower; He Gao; Rachael Quinlan; Charlotte Short; Annachiara Rosa; Chloe Roustan; Maya Moshe; Graham P Taylor; Paul Elliott; Graham S Cooke; Peter Cherepanov; Eleanor Parker; Myra O McClure; Richard S Tedder
Journal:  Sci Rep       Date:  2022-02-03       Impact factor: 4.379

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.