Improving the accuracy of patient positioning for long-leg radiographs using a Taylor Spatial Frame mounted rotation rod.

Marc-Daniel Ahrend1,2, Felix Finger3, Leonard Grünwald3, Gabriel Keller4, Heiko Baumgartner3.   

Abstract

INTRODUCTION: Long-leg radiographs are used to plan and supervise the correction of bone deformity in patients treated with the Taylor Spatial Frame (TSF). Often radiographs are performed with malpositioning of the limb leading to wrong alignment measurements. The aim of this retrospective study was to show the usefulness of a simple device which might enhance the reproducibility of limb rotation on long-leg radiographs.
MATERIALS AND METHODS: We included 20 consecutive patients with TSF treatment and at least three long-leg radiographs (4.9 ± 1.3). Eight out of 20 patients received radiographs with the help of a rotation rod (device with two clamps and a carbon tube). It is placed at the most frontal tab of the reference ring while conducting the radiograph. By this means, limb rotation can be controlled. To show the usefulness of this device, two observers measured the relation of the distances between the middle of the reference ring to the medial and lateral fourth hole on the reference ring (TSF-RR). The standard deviation and range of the TSF-RR of all radiographs for each patient was calculated and compared between patients without and with the rotation rod.
RESULTS: The standard deviations of TSF-RR in patients without the rotation rod was significantly higher compared to patients with rotation rod (observer 1: p = 0.0228, observer 2: p = 0.0038). Also, the range of the TSF-RR within one patient is significant higher (observer 1: p = 0.0279, observer 2: p = 0.0038) in patients without the rotation rod compared to patients with the rotation rod.
CONCLUSIONS: The variability of rotation on radiographs was lower with the rotation rod. Therefore, more reproducible and better comparable radiographs can be conducted. Radiologic exposure might be reduced as repetition of wrongly positioned limbs on radiographs are less frequent.

Entities:  

Keywords:  External fixator; Hexapod; Long-leg radiographs; Rotation; TSF

Mesh:

Year:  2020        PMID: 32377844     DOI: 10.1007/s00402-020-03460-0

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  16 in total

1.  The Taylor spatial frame for deformity correction in the lower limbs.

Authors:  Mohamed Fadel; Gamal Hosny
Journal:  Int Orthop       Date:  2005-02-10       Impact factor: 3.075

2.  Foot rotational effects on radiographic measures of lower limb alignment.

Authors:  Michael A Hunt; Peter J Fowler; Trevor B Birmingham; Thomas R Jenkyn; J Robert Giffin
Journal:  Can J Surg       Date:  2006-12       Impact factor: 2.089

3.  Two stage reconstruction versus bone transport in management of resistant infected tibial diaphyseal nonunion with a gap.

Authors:  Ahmed Fathy Sadek; Mohammed A Laklok; Ezzat H Fouly; Mohamed Elshafie
Journal:  Arch Orthop Trauma Surg       Date:  2016-07-22       Impact factor: 3.067

4.  Correction of tibial malunion and nonunion with six-axis analysis deformity correction using the Taylor Spatial Frame.

Authors:  David S Feldman; Steven S Shin; Sanjeev Madan; Kenneth J Koval
Journal:  J Orthop Trauma       Date:  2003-09       Impact factor: 2.512

5.  Effect of foot rotation on the mechanical axis and correlation between knee and whole leg radiographs.

Authors:  Yong Seuk Lee; Beom Koo Lee; Seung Hoon Lee; Hong Gi Park; Deuk-Soo Jun; Do Hyun Moon
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-02-01       Impact factor: 4.342

Review 6.  Deformity planning for frontal and sagittal plane corrective osteotomies.

Authors:  D Paley; J E Herzenberg; K Tetsworth; J McKie; A Bhave
Journal:  Orthop Clin North Am       Date:  1994-07       Impact factor: 2.472

7.  Staged upper and lower limb lengthening performing bilateral simultaneous surgery of the femur and tibia in achondroplastic patients.

Authors:  Antonio Leiva-Gea; Francisco Borja Delgado-Rufino; Alfonso Queipo-de-Llano; Jorge Mariscal-Lara; Maximiano Lombardo-Torre; Felipe Luna-González
Journal:  Arch Orthop Trauma Surg       Date:  2020-02-11       Impact factor: 3.067

8.  Gradual fibular transfer by ilizarov external fixator in post-traumatic and post-infection large tibial bone defects.

Authors:  Mohammed Anter Meselhy; Mohamed Salah Singer; Abdelsamie M Halawa; Gamal Ahmed Hosny; Adel H Adawy; Osama M Essawy
Journal:  Arch Orthop Trauma Surg       Date:  2018-02-07       Impact factor: 3.067

9.  Insights into treatment and outcome of fracture-related infection: a systematic literature review.

Authors:  H Bezstarosti; E M M Van Lieshout; L W Voskamp; K Kortram; W Obremskey; M A McNally; W J Metsemakers; M H J Verhofstad
Journal:  Arch Orthop Trauma Surg       Date:  2018-10-20       Impact factor: 3.067

10.  Accuracy of complex lower-limb deformity correction with external fixation: a comparison of the Taylor Spatial Frame with the Ilizarov ring fixator.

Authors:  Hans Michael Manner; Michael Huebl; Christof Radler; Rudolf Ganger; Gert Petje; Franz Grill
Journal:  J Child Orthop       Date:  2006-12-30       Impact factor: 1.548

View more
  6 in total

1.  Distance from the magnification device contributes to differences in lower leg length measured in patients with TSF correction.

Authors:  Marc-Daniel Ahrend; Michael Rühle; Fabian Springer; Heiko Baumgartner
Journal:  Arch Orthop Trauma Surg       Date:  2021-03-06       Impact factor: 2.928

2.  Improving postoperative radiographs for the parameter measurement of hexapod external fixator using an additional foot ring.

Authors:  Yanshi Liu; Kai Liu; Feiyu Cai; Tao Zhang; Aihemaitijiang Yusufu
Journal:  J Orthop Surg Res       Date:  2021-11-13       Impact factor: 2.359

3.  Staged correction trajectory with hexapod external fixator for the satisfactory reduction of long bone shaft fracture.

Authors:  Yanshi Liu; Fei Wang; Kai Liu; Feiyu Cai; Xingpeng Zhang; Hong Li; Tao Zhang; Aihemaitijiang Yusufu
Journal:  BMC Musculoskelet Disord       Date:  2022-03-08       Impact factor: 2.362

Review 4.  O papel da estereorradiografia na avaliação das deformidades dos membros inferiores.

Authors:  Flávio Duarte Silva; Renan Nogueira Chemin; Alípio Gomes Ormond Filho; Júlio Brandão Guimarães; Fernando Ometto Zorzenoni; Marcelo Astolfi Caetano Nico
Journal:  Radiol Bras       Date:  2022 Mar-Apr

Review 5.  Influence of axial limb rotation on radiographic lower limb alignment: a systematic review.

Authors:  Marc-Daniel Ahrend; Heiko Baumgartner; Christoph Ihle; Tina Histing; Steffen Schröter; Felix Finger
Journal:  Arch Orthop Trauma Surg       Date:  2021-10-01       Impact factor: 2.928

6.  Long bone fracture reduction and deformity correction using the hexapod external fixator with a new method: a feasible study and preliminary results.

Authors:  Yanshi Liu; Hong Li; Jialin Liu; Xingpeng Zhang; Maimaiaili Yushan; Zhenhui Liu; Chuang Ma; Aihemaitijiang Yusufu
Journal:  BMC Musculoskelet Disord       Date:  2021-02-24       Impact factor: 2.362

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.