PURPOSE: To describe a new technique for transconjunctival intrascleral fixation of Cionni CTR using double-flanged polypropylens suture. METHODS: This is a prospective interventional case series which included 7 cases with severe (more than 180 degrees) zonular dialysis. Three cases were hereditary lens subluxation (Marfan syndrome), 2 cases with traumatic subluxation and 2 cases with pseudo-exfoliation syndrome. RESULTS: All cases achieved a good postoperative stable and centered IOL with good visual results. No postoperative complications were recorded apart from PCO in 3 cases and mild bleeding during needle passage in one case. CONCLUSION: This described technique is a simple, time sparing and minimally invasive method for achieving good bag centration. It eliminates the need of conjunctival peritomy, subconjunctival vessels cautery and scleral fashioning of a flap, pocket or a groove. The use of 6/0 polypropylene theoretically can achieve better longevity.
PURPOSE: To describe a new technique for transconjunctival intrascleral fixation of Cionni CTR using double-flanged polypropylens suture. METHODS: This is a prospective interventional case series which included 7 cases with severe (more than 180 degrees) zonular dialysis. Three cases were hereditary lens subluxation (Marfan syndrome), 2 cases with traumatic subluxation and 2 cases with pseudo-exfoliation syndrome. RESULTS: All cases achieved a good postoperative stable and centered IOL with good visual results. No postoperative complications were recorded apart from PCO in 3 cases and mild bleeding during needle passage in one case. CONCLUSION: This described technique is a simple, time sparing and minimally invasive method for achieving good bag centration. It eliminates the need of conjunctival peritomy, subconjunctival vessels cautery and scleral fashioning of a flap, pocket or a groove. The use of 6/0 polypropylene theoretically can achieve better longevity.
The most common causes of zonular insufficiency are pseudoexfoliation syndrome, trauma, previous ocular surgery (eg, filtering surgery or vitrectomy), hypermature cataracts, and increased axial length. Less common causes include Marfan’s syndrome, homocystinuria, Weill–Marchesani syndrome, microspherophakia, retinitis pigmentosa and intraocular neoplasms.1The Cionni’s modified capsule rings (MCTRs) has an open ring design with one (model I-L or I-R) or two (model 2-L) fixation eyelets attached to the main ring which allows the ring to be fixated to the sclera. This eyelet protrudes 0.25mm forward from the ring and then lays anterior to the anterior capsular rim.1,2Modified capsule tension rings are sutured to the sclera to give a long-term stability for the capsular bag with severe (more than 180 degree) zonular dialysis. Posterior chamber IOLs can be implanted in the bag after being stabilized and centered.1,2After passing the sutures through the eyelets, the sutures are externalized, and tied under a scleral flap, tied under a corneoscleral pocket, or tied over episclera according to surgeon preference, as no technique has been definitively proven superior over the other.4–6This work describes a novel technique to fix the MCTRs to the sclera using a 6/0 polypropylene sutures with double flanges.
Methods
This is a prospective interventional case series which included 7 cases with severe (more than 180 degrees) zonular dialysis. Cases with previous ocular surgeries, glaucoma, posterior segment pathology or corneal opacity were excluded. This work was done according the Declaration of Helsinki and was approved by Alpha Vision center research ethics committee. A written informed consent was obtained from all patients or the parents after explanation of the type of the procedure and the follow up. All cases were done by the same surgeon (A.S).Surgical technique: (As shown in the ).After I/A flexible, iris retractors placed through limbal stab incisions were used to hook the capsulorhexis edge and support the bag during insertion of the MCTR.The Cionni ring was inserted manually with a McPherson forceps and Sinsky hook was used to guide the trailing end to be placed in the bag.The Cionni ring was placed so that the eyelet for scleral fixation was placed at the maximum point of subluxation.A 6/0 polypropylene suture (Prolene®; Ethicon, Somerville, NJ) was introduced through a paracentesis the passes through the eyelet of the ring. A 27-gauge needle was inserted 2 mm behind the limbus transconjunctivally to the sulcus. A microforceps wasused to thread the prolene suture into the lumen of the needle. The needle was withdrawn outside the eye carrying the prolene suture. A hand held ophthalmic cautery (Accu-Temp Cautery; Beaver Visitec, Waltham, MA) wasused to create a flange at the end of the prolene suture at the paracentesis side. To create an adequate sized flange that prevents the suture from passage through the eyelet, more than 5 mm of the suture should be cauterized. The other end of the prolene suture at the scleral side was pulled till the ringwas centered. The suture outside the eye is pulled to the maximum with McPherson forceps in flush with the sclera and the cautery was used to create another bulb then the suture was released till the bulb was totally covered by the conjunctiva and rest in the outer end of the scleral track created by the 27-gauge needle (Figure 1).
Figure 1
(A–H) Shows surgical steps.
(A–H) Shows surgical steps.After the bag was well centered by the scleral-fixated MCTR, a single piece IOL was implanted in the bag.All patients were treated with topical broad spectrum antibiotic drops four times per day and topical prednisolone acetate four times per day. The antibiotic eye drop was stopped after two weeks while the steroid eye drop was tapered over four weeks.The cases were followed up for at least three months for the best corrected visual acuity, IOP, IOL decentration, and presence of complications as endophthalmitis or intraocular hemorrhage.
Results
The technique was used in 7 cases with severe (more than 180 degrees) zonular dialysis.Three cases were hereditary lens subluxation (Marfan syndrome), 2 cases with traumatic subluxation and 2 cases with pseudo-exfoliation syndrome.All cases achieved a good postoperative stable and centered IOL with good visual results. No postoperative complications were recorded apart from PCO in 3 cases and mild bleeding during needle passage in one case (Table 1).
Table 1
Preoperative and Postoperative BCVA, Etiology of Lens Subluxation and Postoperative Complications
Patient
Sex
Age
Cause
Preop BCVA
Postop BCVA
Complication
1
M
69
Pseudoexfoliation
20/70
20/20
NA
2
M
31
Traumatic
20/150
20/40
Bleeding during needle passage
3
F
6
Marfan
20/200
20/30
PCO
4
M
34
Traumatic
20/80
20/20
NA
5
F
9
Marfan
20/100
20/40
PCO
6
M
72
Pseudoexfoliation
20/60
20/20
NA
7
M
8
Marfan
20/150
20/30
PCO
Preoperative and Postoperative BCVA, Etiology of Lens Subluxation and Postoperative Complications
Discussion
Capsular tension rings (CTRs) and other endocapsular devices have become well-established tool that allow surgeons to deal with zonular weakness with increased safety. The choice of capsular tension device in a particular surgery depends on the amount of zonular dehiscence as well as the likelihood of progression. CTRs can re-center a mildly subluxated capsular bag, but it will not recenter a severely subluxated capsular bag nor will it cure a progressive zonulopathy. In these situations, a modified CTR (MCTR) or a capsular tension segment (CTS) provides a stable long-term solution through scleral-fixation.2The standard method of Trans- scleral fixation of Cionni ring for stabilization of capsular bag in cases of zonular dialysis,involves conjunctival peritomy, caurety of subconjunctival vessels, scleral flaps groove or pocket creation which is time consuming and needs along learning curve.5,6Suture material should be permanent. Polypropylene 10–0 is commonly used but it will hydrolyze over time with a roughly 5- to 10-year survival time. Polypropylene 9–0 should have a longer survival time. The interval before degradation of this suture gauge has not been reported. A polytetrafluoroethylene CV-8 suture has been used for scleral fixation off label and to date has had excellent longevity.3This described technique is a simple, time sparing and minimally invasive method for achieving good bag centration. It eliminates the need of conjunctival peritomy, subconjunctival vessels cautery and scleral fashioning of a flap, pocket or a groove. The use of 6/0 prolene theoretically can achieve better longevity. However longer period of follow up is required.