Abstract

PURPOSE: To evaluate the intraoperative performance and postoperative outcomes of toric intraocular lens (IOL) with suture ring implantation in adult patients with subluxated lenses.
SETTING: Department of Ophthalmology, Kaiser Permanente, Santa Clara, California, and the Eye Institute of Utah, Salt Lake City, Utah, USA.
DESIGN: Retrospective case review.
METHODS: Eyes with subluxated cataractous lenses and preoperative corneal astigmatism having toric IOL implantation with a sutured ring or segment were studied. Preoperative and postoperative analyses included uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and cylindrical power postoperatively and 3, 6, and 12 months postoperatively.
RESULTS: Twenty-one eyes of 15 patients were studied. The median follow-up was 14.6 months. The mean CDVA at the final follow-up (0.10 logMAR ± 0.15 [SD]) was significantly improved from the mean preoperative CDVA (0.73 ± 0.40 logMAR). Postoperative cylindrical power was significantly improved in all patients (mean reduction in astigmatism 2.37 ± 1.46 diopters). Patients who required postoperative enhancement had anterior laser capsulotomy for bilateral capsule phimosis (2 eyes), photorefractive keratectomy (1 eye), pupilloplasty (1 eye), and posterior laser capsulotomy (2 eyes).
CONCLUSION: Cataract removal and implantation of a toric IOL combined with a sutured ring or segment capsule stabilizing device was a safe and efficacious long-term solution for patients with subluxated cataract lenses and corneal astigmatism.
Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2016        PMID: 27063519     DOI: 10.1016/j.jcrs.2015.10.070

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  4 in total

1.  [Application of femtosecond laser technology in the management of subluxated lens].

Authors:  Ruihong Ju; Yun Chen; Wei Yang; Mansha He; Yuanhong Pan; Zheming Wu
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2019-07-30

2.  Two-Year Follow-Up of Clinical Efficacy of Femtosecond Laser, Modified Capsular Tension Ring, and Iris Hook-Assisted Surgical Treatment of Lens Subluxation in Patients with Elevated Intraocular Pressure.

Authors:  Chao Wang; Yuhua Rui; Yi Zhou; Tu Hu; Xiaobo Xia; Jian Jiang
Journal:  J Ophthalmol       Date:  2022-05-09       Impact factor: 1.974

3.  Corneal Curvature, Astigmatism, and Aberrations in Marfan Syndrome with Lens Subluxation: Evaluation by Pentacam HR System.

Authors:  Jiahui Chen; Qinghe Jing; Yating Tang; Dongjin Qian; Yi Lu; Yongxiang Jiang
Journal:  Sci Rep       Date:  2018-03-06       Impact factor: 4.379

4.  Double-Flanged polypropylene Suture for Scleral Fixation of Cionni Capsule Tension Ring.

Authors:  Ahmed Samir; Ayman M Abdelrahman Elsayed; Ahmed Alyan; Ayman Lotfy
Journal:  Clin Ophthalmol       Date:  2020-04-20
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.