Cleaning, Shaping, and Disinfecting Abilities of 2 Instrument Systems as Evaluated by a Correlative Micro-computed Tomographic and Histobacteriologic Approach.

Alejandro R Pérez1, Domenico Ricucci2, Gaya C S Vieira1, José C Provenzano1, Flávio R F Alves3, Marília F Marceliano-Alves1, Isabela N Rôças4, José F Siqueira4.   

Abstract

INTRODUCTION: This study assessed the cleaning, shaping, and disinfection abilities of 2 instrumentation systems in molar root canals using a novel correlative analytical approach.
METHODS: The root canals from extracted mandibular and maxillary molars with apical periodontitis were pair matched according to anatomic similarities as determined by micro-computed tomographic analysis and prepared with either XP-endo Shaper (FKG Dentaire, La Chaux-de-Fonds, Switzerland) (n = 16) or Reciproc Blue (VDW, Munich, Germany) (n = 16) instruments and 2.5% sodium hypochlorite irrigation. Pre- and postpreparation micro-computed tomographic scans were used to identify and calculate the unprepared surface areas (shaping), which were histobacteriologically evaluated for the presence of residual bacteria (disinfection) and pulp tissue remnants (cleaning) in each canal third.
RESULTS: Unprepared canal surface areas for XP-endo Shaper and Reciproc Blue in the full canal length were approximately 26% and 19% (P < .05), respectively (30% and 23% in the apical part of the canal, P > .05). Preparation with Reciproc Blue resulted in 37.5% canals free of bacteria in all sections examined and 56% in the apical sections only. XP-endo Shaper resulted in 44% canals free of bacteria in all sections, and 56% in the apical part of the canal only. Pulp tissue remnants were not observed in 31% (all canal sections) and 50% (apical canal sections) of specimens from both instrument systems. No significant differences were observed between instruments when comparing the amount of pulp tissue remnants and the number of cases negative for bacteria and tissue remnants (P > .05).
CONCLUSIONS: Although the Reciproc Blue instrument had superior shaping ability in comparison with XP-endo Shaper, both systems performed similarly in cleaning and disinfecting root canals. Irregular canals and difficult-to-reach areas were not thoroughly cleaned and disinfected by any of the tested systems.
Copyright © 2020 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Apical periodontitis; bacterial persistence; histobacteriology; micro–computed tomography; root canal preparation

Year:  2020        PMID: 32362378     DOI: 10.1016/j.joen.2020.03.017

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  3 in total

1.  Unprepared surface areas, accumulated hard tissue debris, and dentinal crack formation after preparation using reciprocating or rotary instruments: a study in human cadavers.

Authors:  Andrea F Campello; Marília F Marceliano-Alves; José F Siqueira; Simone C Fonseca; Ricardo T Lopes; Flávio R F Alves
Journal:  Clin Oral Investig       Date:  2021-04-26       Impact factor: 3.573

2.  Ex vivo ability of a noninstrumentation technique to disinfect oval-shaped canals.

Authors:  Ghassan Yared; Ghada Asmar Ramli
Journal:  J Conserv Dent       Date:  2020-10-10

3.  Quaternary ammonium silane (k21) based intracanal medicament triggers biofilm destruction.

Authors:  Esther Sook Kuan Kok; Xian Jin Lim; Soo Xiong Chew; Shu Fen Ong; Lok Yin See; Siao Hua Lim; Ling Ang Wong; Fabian Davamani; Venkateshbabu Nagendrababu; Amr Fawzy; Umer Daood
Journal:  BMC Oral Health       Date:  2021-03-12       Impact factor: 2.757

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.