Literature DB >> 32358268

Determining vault size in implantable collamer lenses: preoperative anatomy and lens parameters.

Angel Sánchez Trancón1, Santiago Cerpa Manito, Oscar Torrado Sierra, António Manuel Baptista, Pedro Miguel Serra.   

Abstract

PURPOSE: To determine patient preoperative anatomical features and the parameters of implantable collamer lenses (ICLs) relevant in explaining vault variability.
SETTING: Ophthalmology Clinic Vista Sánchez Trancón, Badajoz, Spain.
DESIGN: Retrospective case series.
METHODS: This study comprised 360 eyes of 360 patients implanted with myopic or toric ICLs. Pentacam imaging was used for assessing white-to-white (WTW) diameter, central keratometry, and central corneal thickness. Anterior-segment optical coherence tomography was used to measure the horizontal anterior chamber angle distance (ATA), internal anterior chamber (ACQ), crystalline lens rise (CLR), anterior chamber angle (ACA), and vault. The sample was divided according to the implanted lens size (12.6 mm, 13.2 mm, and 13.7 mm). Vault predictors were identified from the variables above using multivariate regression analysis.
RESULTS: The groups showed significant statistical differences for WTW, ATA, ACQ, ACA, and vault (P < .007 for all). In general, bigger lenses were implanted in eyes with larger transverse sizes (WTW and ATA) and deeper ACQ. Also, larger ICL diameters were associated with higher vaults. Multivariate regression analysis identified the lens size (13.2 mm as reference; 12.6 mm: β [standardized coefficients] = -0.33; 13.7 mm: β = 0.42), ATA (β = -0.42), and CLR (β = -0.25), ICL spherical equivalent (β = -0.22) and patient age (β = -0.12) as predictors of the vault size (adjusted-R = 0.34 P < .001).
CONCLUSIONS: The multivariate model explained 34% of vault variability. The predictors indicated the presence of different mechanisms regulating the vault. These involved the difference between the transverse size of the eye and the ICL, the crystalline lens protrusion, and the ICL properties, such as power and size.

Entities:  

Mesh:

Year:  2020        PMID: 32358268     DOI: 10.1097/j.jcrs.0000000000000146

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  8 in total

1.  Clinical Prediction of Inadequate Vault in Eyes With Thick Lens After Implantable Collamer Lens Implantation Using Iris Morphology.

Authors:  Zhikun Yang; Lihui Meng; Xinyu Zhao; Youxin Chen; Yan Luo
Journal:  Front Med (Lausanne)       Date:  2022-06-09

2.  Inter-eye and postoperative prediction of vault after implantation of EVO + Visian phakic implantable collamer lens.

Authors:  Elena Martínez-Plaza; Alberto López-Miguel; Alberto López-de la Rosa; Miguel J Maldonado
Journal:  Int Ophthalmol       Date:  2022-10-19       Impact factor: 2.029

3.  Short-term changes in and preoperative factors affecting vaulting after posterior chamber phakic Implantable Collamer Lens implantation.

Authors:  Qiu-Jian Zhu; Wen-Jing Chen; Wei-Jian Zhu; Hai-Xiang Xiao; Man-Hui Zhu; Lie Ma; You Yuan; E Song
Journal:  BMC Ophthalmol       Date:  2021-05-06       Impact factor: 2.209

4.  Correlation between intraoperative and postoperative vaulting of the EVO implantable Collamer lens: a retrospective study of real-time observations of vaulting using the RESCAN 700 system.

Authors:  Nian Guan; Xiao-Nong Zhang; Wan-Jun Zhang
Journal:  BMC Ophthalmol       Date:  2022-01-03       Impact factor: 2.209

5.  Outcomes of the EVO ICL Using a Customized Non-horizontal or Horizontal Implanting Orientation Based on UBM Measurement: A Pilot Study.

Authors:  Ruoyan Wei; Mingrui Cheng; Lingling Niu; Lin Wang; Xiumei Luo; Meiyan Li; Xiaodong Zhou; Xiaoying Wang; Xingtao Zhou; Peijun Yao
Journal:  Ophthalmol Ther       Date:  2022-04-12

6.  Safety and anterior chamber structure of evolution implantable Collamer lens implantation with short white-to-white corneal diameters.

Authors:  Xun Chen; Fang Chen; Xuanqi Wang; Yilin Xu; Mingrui Cheng; Tian Han; Xiaoying Wang; Xingtao Zhou
Journal:  Front Med (Lausanne)       Date:  2022-08-17

7.  A prediction model for sulcus-to-sulcus diameter in myopic eyes: a 1466-sample retrospective study.

Authors:  Qiu-Jian Zhu; Wei-Jian Zhu; Wen-Jing Chen; Lie Ma; You Yuan
Journal:  BMC Ophthalmol       Date:  2022-07-16       Impact factor: 2.086

8.  Development of a Web-Based Ensemble Machine Learning Application to Select the Optimal Size of Posterior Chamber Phakic Intraocular Lens.

Authors:  Eun Min Kang; Ik Hee Ryu; Geunyoung Lee; Jin Kuk Kim; In Sik Lee; Ga Hee Jeon; Hojin Song; Kazutaka Kamiya; Tae Keun Yoo
Journal:  Transl Vis Sci Technol       Date:  2021-05-03       Impact factor: 3.283

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.