| Literature DB >> 32344704 |
Carmela Protano1, Maurizio Manigrasso2, Vittoria Cammalleri1, Giuseppe Biondi Zoccai3,4, Giacomo Frati3,5, Pasquale Avino6, Matteo Vitali1.
Abstract
An aerosol study was carried out in a test room measuring particulate matter (PM) with an aerodynamic diameter smaller than 10, 4, 2.5 and 1 µm (PM10, PM4, PM2.5, PM1) before and during the use of electronic alternatives to tobacco cigarettes (EATC) IQOS®, GLO®, JUUL®, with different kinds of sticks/pods, as well as during the smoking of a conventional tobacco cigarette. The aerosol was mainly in the PM1 size range (>95%). All studied EATCs caused lower indoor PM1 concentrations than conventional tobacco cigarettes. Nevertheless, they determined a worsening of indoor-PM1 concentration that ranged from very mild for JUUL®-depending on the pod used-to considerably severe for IQOS® and GLO®. Median values ranged from 11.00 (Iqos3 and Juul2) to 337.5 µg m-3 (Iqos4). The high variability of particle loadings was attributed both to the type of stick/pod used and to the different way of smoking of volunteers who smoked/vaped during the experiments. Moreover, during vaping IQOS® and GLO® indoor PM1 concentrations reach levels by far higher than outdoor concentrations that range from 14 to 21 µg m-3, especially during the exhalation of the smoke. From these results emerge an urgent need of a legislative regulation limiting the use of such devices in public places.Entities:
Keywords: GLO®; IQOS®; JUUL®; electronic cigarettes; heat-not-burn products; indoor air; particulate matter; passive smoking
Year: 2020 PMID: 32344704 PMCID: PMC7254302 DOI: 10.3390/ijerph17082947
Source DB: PubMed Journal: Int J Environ Res Public Health ISSN: 1660-4601 Impact factor: 3.390
Devices, flavors and relative codes of the experiments.
| EATC Types | Stick/Pod | Code |
|---|---|---|
| IQOS® | Heets Amber label | Iqos1 |
| Heets Blue label | Iqos2 | |
| Heets Bronze label | Iqos3 | |
| Heets Sienna label | Iqos4 | |
| Heets Turquoise label | Iqos5 | |
| Heets Yellow label | Iqos6 | |
| GLO® | Neo Aegean stick | Glo1 |
| Neo Beryl stick | Glo2 | |
| Neo Ultramarine stick | Glo3 | |
| Neo Yellow stick | Glo4 | |
| JUUL® | Golden Tobacco | Juul1 |
| Mango | Juul2 | |
| Mint | Juul3 | |
| Royal Creme | Juul4 | |
| Marlboro® gold | – | Marlboro |
Figure 1Levels of particulate matter with an aerodynamic diameter smaller than 1 (PM1) (a), 2.5 (PM2.5) (b), 4 (PM4) (c), and 10 µm (PM10) (d) (values expressed as Log10) measured before and during the vaping session of an Iqos1. Red line divided the concentrations measured before and those measured during the vaping session.
Air levels of PM with an aerodynamic diameter smaller than 1 µm (PM1; μg m−3) before and during each experiment.
| Experiment Code | Before Experiment | During Experiment (10–12 Puff for about 5–6 min) | |||
|---|---|---|---|---|---|
| Arithmetic Mean [Standard Deviation] | Median [Interquartile Range] | Arithmetic Mean [Standard Deviation] | Median [Interquartile Range] | ||
| Iqos1 | 14.2 [3.7] | 13.0 [3.0] | 517.7 [1048.9] | 70.0 [383.0] | <0.001 |
| Iqos2 | 14.6 [6.5] | 13.0 [2.0] | 132.0 [619.3] | 21.0 [12.0] | <0.001 |
| Iqos3 | 9.2 [1.5] | 9.0 [2.0] | 112.3 [469.4] | 11.0 [5.0] | <0.001 |
| Iqos4 | 9.1 [5.8] | 7.0 [1.0] | 1511.3 [2707.2] | 337.5 [1568.0] | <0.001 |
| Iqos5 | 23.7 [4.6] | 22.0 [6.0] | 32.4 [8.4] | 32.0 [16.0] | <0.001 |
| Iqos6 | 10.7 [2.1] | 10.0 [2.0] | 49.8 [128.8] | 21.0 [19.0] | <0.001 |
| Glo1 | 8.8 [2.4] | 8.0 [2.0] | 552.6 [1477.5] | 66.0 [205.5] | <0.001 |
| Glo2 | 8.7 [0.9] | 8.0 [1.0] | 42.0 [115.1] | 13.0 [9.0] | <0.001 |
| Glo3 | 26.9 [1.7] | 27.0 [2.0] | 406.5 [1335.6] | 31.0 [101.0] | <0.001 |
| Glo4 | 12.1 [1.9] | 12.0 [2.0] | 117.7 [336.8] | 23.0 [38.0] | <0.001 |
| Juul1 | 8.3 [2.3] | 7.5 [1.0] | 1637.9 [6387.6] | 110.0 [289.0] | <0.001 |
| Juul2 | 10.9 [1.5] | 10.0 [1.0] | 37.7 [208.3] | 11.0 [3.0] | <0.001 |
| Juul3 | 13.8 [1.9] | 13.0 [4.0] | 16.7 [5.4] | 15.0 [4.0] | <0.001 |
| Juul4 | 13.3 [1.5] | 13.0 [2.0] | 16.0 [5.0] | 15.0 [4.0] | <0.001 |
| Marlboro | 3.9 [1.2] | 4.0 [1.0] | 8638.5 [1,2215.9] | 3430.0 [8620.0] | <0.001 |
Figure 2Mean levels of PM with an aerodynamic diameter smaller than 1 µm (PM1 expressed as Log10PM1) measured during each experiment.
Pairwise post hoc tests between the levels of PM with an aerodynamic diameter smaller than 1 µm (PM1; μg m−3) measured in each experiment.
| Iqos2 | Iqos3 | Iqos4 | Iqos5 | Iqos6 | Glo1 | Glo2 | Glo3 | Glo4 | Juul1 | Juul2 | Juul3 | Juul4 | Marlboro Gold | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| * | * | * | * | * | * | * | * | * | * | * | * | * | * | |
| * | * | * | * | * | * | * | * | * | * | * | * | * | ||
| * | * | * | * | ns | * | * | * | ns | ns | ns | * | |||
| * | * | * | * | * | * | * | * | * | * | * | ||||
| * | * | * | * | * | * | * | * | * | * | |||||
| * | * | * | * | * | * | * | * | * | ||||||
| * | * | * | * | * | * | * | * | |||||||
| * | * | * | ns | ns | ns | * | ||||||||
| * | * | * | * | * | * | |||||||||
| * | * | * | * | * | ||||||||||
| * | * | * | * | |||||||||||
| * | * | * | * | |||||||||||
| * | * | * | ||||||||||||
* = p-Value (calculated probability) <0.05; ns = not significant: p-Value (calculated probability) >0.05.