| Literature DB >> 32337182 |
Ghorbani M1, Ebrahimi Bardar M2.
Abstract
BACKGROUND: Neutron contamination is produced in electron beams of linac when tooth or dental materials are located in the path of beam.Entities:
Keywords: Electron Beam; Monte Carlo Method; Neutrons; Restoration Material; Siemens Primus linac; Tooth
Year: 2020 PMID: 32337182 PMCID: PMC7166217 DOI: 10.31661/jbpe.v0i0.920
Source DB: PubMed Journal: J Biomed Phys Eng ISSN: 2251-7200
Figure 1The relative neutron contamination dose in the case of tooth/restored tooth with Ceramco C3 veneer, Eclipse alloy and amalgam restoration materials. The data for the 8-14 MeV beams are shown in parts (a)-(c), respectively
The relative neutron contamination dose in a phantom for the case of tooth/dental materials for 8-14 MeV beams.
| 8 MeV | 12 MeV | 14 MeV | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Depth (cm) | Tooth | Tooth restored with Ceramco | Tooth restored with Eclipse | Tooth restored with Amalgam | Depth (cm) | Tooth | Tooth restored with Ceramco | Tooth restored with Eclipse | Tooth restored with Amalgam | Depth (cm) | Tooth | Tooth restored with Ceramco | Tooth restored with Eclipse | Tooth restored with Amalgam |
| 0.4 | 1.00 | 1.00 | 0.97 | 1.01 | 1.6 | 1.10 | 1.06 | 1.12 | 1.10 | 1.2 | 1.00 | 1.00 | 1.00 | 1.01 |
| 1.3 | 1.00 | 1.00 | 0.98 | 1.00 | 2.6 | 1.11 | 1.12 | 1.14 | 1.09 | 2.2 | 1.00 | 1.00 | 1.02 | 1.01 |
| 2.3 | 1.01 | 1.04 | 0.95 | 1.05 | 3.6 | 1.09 | 1.16 | 1.25 | 1.09 | 3.2 | 1.01 | 1.01 | 1.07 | 1.03 |
| 4.1 | 0.95 | 0.98 | 0.95 | 1.01 | 5.4 | 1.04 | 1.08 | 1.52 | 1.08 | 4.2 | 1.04 | 1.03 | 1.27 | 1.16 |
| 5.1 | 1.04 | 1.06 | 1.01 | 1.07 | 6.4 | 1.04 | 1.04 | 1.25 | 1.10 | 6 | 1.05 | 1.05 | 1.53 | 1.21 |
| 6.1 | 1.06 | 1.16 | 1.02 | 1.17 | 7.4 | 1.03 | 1.04 | 1.15 | 1.07 | 7 | 1.04 | 1.04 | 1.20 | 1.10 |
shows depths that positioned before the tooth