Literature DB >> 26581762

Evaluation of the effect of tooth and dental restoration material on electron dose distribution and production of photon contamination in electron beam radiotherapy.

Mohammad Taghi Bahreyni Toossi1, Mahdi Ghorbani2, Fatemeh Akbari3, Mohammad Mehrpouyan4,5, Leila Sobhkhiz Sabet3.   

Abstract

The aim of this study is to evaluate the effect of tooth and dental restoration materials on electron dose distribution and photon contamination production in electron beams of a medical linac. This evaluation was performed on 8, 12 and 14 MeV electron beams of a Siemens Primus linac. MCNPX Monte Carlo code was utilized and a 10 × 10 cm(2) applicator was simulated in the cases of tooth and combinations of tooth and Ceramco C3 ceramic veneer, tooth and Eclipse alloy and tooth and amalgam restoration materials in a soft tissue phantom. The relative electron and photon contamination doses were calculated for these materials. The presence of tooth and dental restoration material changed the electron dose distribution and photon contamination in phantom, depending on the type of the restoration material and electron beam's energy. The maximum relative electron dose was 1.07 in the presence of tooth including amalgam for 14 MeV electron beam. When 100.00 cGy was prescribed for the reference point, the maximum absolute electron dose was 105.10 cGy in the presence of amalgam for 12 MeV electron beam and the maximum absolute photon contamination dose was 376.67 μGy for tooth in 14 MeV electron beam. The change in electron dose distribution should be considered in treatment planning, when teeth are irradiated in electron beam radiotherapy. If treatment planning can be performed in such a way that the teeth are excluded from primary irradiation, the potential errors in dose delivery to the tumour and normal tissues can be avoided.

Entities:  

Keywords:  Dental restoration material; Electron mode; Monte Carlo simulation; Tooth

Mesh:

Year:  2015        PMID: 26581762     DOI: 10.1007/s13246-015-0404-z

Source DB:  PubMed          Journal:  Australas Phys Eng Sci Med        ISSN: 0158-9938            Impact factor:   1.430


  2 in total

1.  Determination of dosimetric parameters for shielded 153Gd source in prostate cancer brachytherapy.

Authors:  Mahdi Ghorbani; Benyamin Khajetash; Najmeh Ghatei; Mohammad Mehrpouyan; Ali S Meigooni; Ramin Shahraini
Journal:  Radiol Oncol       Date:  2017-02-22       Impact factor: 2.991

2.  Dental Materials Effect in Neutron Contamination: Electron Mode of a Linac.

Authors:  Ghorbani M; Ebrahimi Bardar M
Journal:  J Biomed Phys Eng       Date:  2020-04-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.