Physiologic Effects from Using Tight- and Loose-Fitting Powered Air-Purifying Respirators on Inhaled Gases, Peak Pressures, and Inhalation Temperatures During Rest and Exercise.

Edward J Sinkule1, Jeffrey B Powell1, Elaine N Rubinstein2, Linda McWilliams2, Tyler Quinn1, Marco Pugliese3.   

Abstract

The goal of this investigation was to evaluate the physiologic stresses of powered air-purifying respirators (PAPRs) used by workers in many industries (e.g., health care, automobile repair, public safety, building trades, etc.) during rest and three levels of energy expenditure. Twelve men and twelve women wore one tight-fitting and three loose-fitting PAPRs at rest (REST) and while walking for four minutes at oxygen consumption (V̇O2) rates of 1.0 l·min-1(LOW), 2.0 l·min-1 (MODERATE), and 3.0 l·min-1 or maximum (HIGH). Minimum inhaled carbon dioxide concentration (FICO2), maximum inhaled oxygen concentration (FIO2), peak inhalation pressure, and end inhalation temperature were measured continuously breath-by-breath. Repeated measures analysis of variance found that neither the main effect of gender, nor any interactions involving gender were significant. The highest minimum FICO2 among PAPRs occurred for MODERATE and HIGH energy expenditures while wearing the loose-fitting PAPR with the largest dead space. The lowest maximum FIO2 was observed during HIGH intensity energy expenditure also for the loose-fitting PAPR with the largest dead space. Among all PAPR models, peak inhalation pressures were negative at V̇O2 > LOW, suggesting that peak inhalation flow was greater than blower flow. Results using the variables reported here suggest that PAPRs used at various levels of energy expenditure may be tolerated among healthy workers. Further research is needed to determine the source of supplemented air when inhalation flow exceeds blower flow.

Entities:  

Keywords:  PAPR; inhaled gas; inhaled temperature; overbreathing; peak pressure; personal protective equipment; respiratory protection

Year:  2016        PMID: 32336877      PMCID: PMC7183739     

Source DB:  PubMed          Journal:  J Int Soc Respir Prot        ISSN: 0892-6298


  14 in total

1.  Threshold of response of the cerebral vessels of man to increase in blood carbon dioxide.

Authors:  J L PATTERSON; A HEYMAN; L L BATTEY; R W FERGUSON
Journal:  J Clin Invest       Date:  1955-12       Impact factor: 14.808

2.  Effects on man of high concentrations of carbon dioxide in relation to various oxygen pressures during exposures as long as 72 hours.

Authors:  W V CONSOLAZIO; M B FISHER
Journal:  Am J Physiol       Date:  1947-12-01

3.  Temperature sensitivity of the body surface over the life span.

Authors:  J C Stevens; K K Choo
Journal:  Somatosens Mot Res       Date:  1998       Impact factor: 1.111

4.  Powered air purifying respirators: versatility beyond respiratory protection.

Authors:  Karen Cuta
Journal:  Occup Health Saf       Date:  2014-11

Review 5.  The physiological consequences of wearing industrial respirators: a review.

Authors:  P B Raven; A T Dodson; T O Davis
Journal:  Am Ind Hyg Assoc J       Date:  1979-06

6.  Physiologic effects of respirator dead space and resistance loading.

Authors:  P Harber; R J Tamimie; A Bhattacharya; M Barber
Journal:  J Occup Med       Date:  1982-09

7.  Quantitative assessment of thermal and pain sensitivity.

Authors:  D Meh; M Denislic
Journal:  J Neurol Sci       Date:  1994-12-20       Impact factor: 3.181

8.  Prevalence of Respiratory Protective Devices in U.S. Health Care Facilities: Implications for Emergency Preparedness.

Authors:  Kerri Wizner; Lindsay Stradtman; Debra Novak; Ronald Shaffer
Journal:  Workplace Health Saf       Date:  2016-08       Impact factor: 1.413

9.  Evaluation of N95 respirator use with a surgical mask cover: effects on breathing resistance and inhaled carbon dioxide.

Authors:  Edward James Sinkule; Jeffrey Bryon Powell; Fredric Lee Goss
Journal:  Ann Occup Hyg       Date:  2012-10-29

10.  The changing face of healthcare worker perceptions on powered air-purifying respirators during the SARS outbreak.

Authors:  Kay-Leong Khoo; Poh-Hock Leng; Irwani Bte Ibrahim; T K Lim
Journal:  Respirology       Date:  2005-01       Impact factor: 6.424

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.