Simultaneous determination of the dose and linear energy transfer (LET) of carbon-ion beams using radiochromic films.

Motohiro Kawashima1, Akihiko Matsumura, Hikaru Souda, Mutsumi Tashiro.   

Abstract

Radiochromic films are useful as dosimeters in high-precision radiotherapy owing to their high spatial resolution. However, when a particle beam is measured using a radiochromic film, the dose cannot be estimated accurately because the film darkness varies with variations in linear energy transfer (LET). This paper proposes a novel method for estimating the LET and the dose based on the film darkness. In this method, after a high-LET particle beam, such as a carbon-ion beam, was incident on the film, the film was digitized and its net optical density was determined. Further, the non-linearity of the film response curve between the dose and the darkness, depending on LET, was used. Then, calibration curves were created using 290 MeV u-1 mono energetic carbon-ion beams. We used LETs of 20, 50, 100, and 150 keV µm-1 and a physical dose of 2-14 Gy. The calibration curves were approximated for each LET using a quadratic function. The correlations between the coefficients of the quadratic function and the LET were also obtained. To verify the proposed method, the films were irradiated under 12 different conditions corresponding to various depths and doses. Four depths of -2, -5, -10, and -20 mm with respect to the Bragg peak, and three different preset values were used for the film measurements. The films were analyzed in four groups, where each group comprised films irradiated at the same depth. The LETs obtained from the film analysis, ordered from the upstream of the beam, were 20, 41, 56, and 97 keV µm-1, and the doses for the lowest preset value were 3.95, 4.07, 4.03, and 3.99 Gy for the four groups. The LETs obtained from the film analysis increased toward the Bragg peak, and the doses measured in the ionization chamber were almost equal to 4 Gy.

Entities:  

Mesh:

Substances:

Year:  2020        PMID: 32320970     DOI: 10.1088/1361-6560/ab8bf3

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Improved simultaneous LET and dose measurements in proton therapy.

Authors:  Jeppe Brage Christensen; Michele Togno; Lily Bossin; Oskari Ville Pakari; Sairos Safai; Eduardo Gardenali Yukihara
Journal:  Sci Rep       Date:  2022-05-18       Impact factor: 4.996

2.  Dual-storage phosphor proton therapy dosimetry: Simultaneous quantification of dose and linear energy transfer.

Authors:  Jufri Setianegara; Thomas R Mazur; Deshan Yang; H Harold Li
Journal:  Med Phys       Date:  2021-02-19       Impact factor: 4.071

3.  Linear energy transfer-independent calibration of radiochromic film for carbon-ion beams.

Authors:  Mutsumi Tashiro; Motohiro Kawashima
Journal:  Phys Imaging Radiat Oncol       Date:  2022-08-08
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.