Literature DB >> 3230513

Posterior capsular opacification and intraocular lens decentration. Part I: Comparison of various posterior chamber lens designs implanted in the rabbit model.

S O Hansen1, K D Solomon, G T McKnight, T H Wilbrandt, T D Gwin, D J O'Morchoe, M R Tetz, D J Apple.   

Abstract

Experimental phacoemulsification procedures were performed in 54 Rex rabbits. In 96 eyes, posterior chamber intraocular lenses (IOLs) were implanted in the capsular sac, and 12 eyes served as controls with no lens implantation. The IOLs were divided into eight groups consisting of both one-piece and three-piece styles with various optic designs. Each lens was evaluated for the relative effect on posterior capsular opacification (PCO) and optic decentration, two of the most common complications of modern cataract surgery and IOL implantation. Optics with a convex-anterior, plano-posterior design (the type of IOL optic most frequently implanted today) had the highest incidence of PCO. With capsular fixated IOLs, the features that have a statistically significant impact on reducing PCO include (1) one-piece, all-polymethylmethacrylate (PMMA) IOL styles, (2) a biconvex or posterior convex optic design, and (3) angulated loops. Lens decentration was not affected by the optic design, but statistical analysis showed that one-piece, all-PMMA IOL construction provided the most consistent centration.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3230513     DOI: 10.1016/s0886-3350(88)80027-0

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  5 in total

Review 1.  [New methods for the prevention of posterior capsule opacification].

Authors:  G U Auffarth; T M Rabsilber; A J Reuland
Journal:  Ophthalmologe       Date:  2005-06       Impact factor: 1.059

2.  Influence of intraocular lens material and design on postoperative intracapsular cellular reactivity.

Authors:  D J Apple
Journal:  Trans Am Ophthalmol Soc       Date:  2000

3.  Lens capsule opacification in aphakic and pseudophakic eyes.

Authors:  M P Nasisse; M J Dykstra; L M Cobo
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1995-02       Impact factor: 3.117

4.  Comparison of decentration and tilt between one piece and three piece polymethyl methacrylate intraocular lenses.

Authors:  K Hayashi; H Hayashi; F Nakao; F Hayashi
Journal:  Br J Ophthalmol       Date:  1998-04       Impact factor: 4.638

5.  Lens epithelial cell regression on the posterior capsule with different intraocular lens materials.

Authors:  E J Hollick; D J Spalton; P G Ursell; M V Pande
Journal:  Br J Ophthalmol       Date:  1998-10       Impact factor: 4.638

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.