| Literature DB >> 32303789 |
Kornelia Kreiser1, Lea Ströber2, Kim G Gehling2, Frederick Schneider3, Stefan Kohlbecher4, Christian M Schulz3, Claus Zimmer2, Jan S Kirschke2.
Abstract
PURPOSE: Simulators are increasingly used in the training of endovascular procedures; however, for the use of the Mentice vascular interventional system trainer (VIST) simulator in neuroradiology, the validity of the method has not yet been proven. The study was carried out to test the construct validity of such a simulator by demonstrating differences between beginner and expert neurointerventionalists and to evaluate whether a training effect can be demonstrated in repeated cases for different levels of experience.Entities:
Keywords: Eye tracking; Neuroradiology; Training effect; Validity; Work load
Year: 2020 PMID: 32303789 PMCID: PMC8211587 DOI: 10.1007/s00062-020-00902-5
Source DB: PubMed Journal: Clin Neuroradiol ISSN: 1869-1439 Impact factor: 3.649
Fig. 1Simulation set-up with VIST LAB and eye tracking camera (heart rate belt covered by shirt)
Comparison of experts and beginners in a summary of all 10 simulations (one expert only performed simulations 1–5)
| Simulations 1–10 | |||||
|---|---|---|---|---|---|
| Experts ( | Beginners ( | ||||
| Total duration (min) | 19.65 | 7.73 | 31.96 | 15.07 | |
| Fluoroscopy time (min) | 11.91 | 4.59 | 18.78 | 7.72 | |
| Total time of series (min) | 1.90 | 0.80 | 1.75 | 0.79 | |
| Contrast agent (ml) | 52.04 | 21.31 | 67.20 | 30.82 | |
| – | |||||
| Number of series | 16 | 10 | 16.5 | 9 | |
| Number of material changes | 1 | 1 | 2 | 2 | |
| Mental demand | 9.5 | 8 | 10.5 | 7 | |
| Physical demand | 4.5 | 4 | 5 | 4 | |
| Temporal demand | 7.5 | 7 | 6 | 6 | |
| Satisfaction with performance | 17 | 4 | 15 | 6 | |
| Effort | 11 | 7 | 15 | 5 | |
| Frustration | 6 | 4 | 5 | 5 | |
| Heart rate (beats per minute/bpm) | 79.00 | 8.92 | 81.47 | 13.86 | |
| Viewing direction (%)a | 29.38 | 14.40 | 30.08 | 14.60 | |
Median and IQR for number of series, number of material changes and results of NASA-TLX, p-values of mediantest <0.05 are in bold type. Mean for total duration, fluoroscopy time, total time of series and amount of contrast agent, heart rate and gaze direction, p-values of Mann Whitney U‑test <0.05 are in bold type
aPercentage of deviation of more than 30° from the horizontal view downwards.
Comparison of experts and beginners of simulations 1–5 and 6–10 separately
| Experts | Beginners | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Simulation ( | Simulation 6–10 | Simulation 1–5 ( | Simulation 6–10 ( | |||||||
Total duration (min) | 21.88 | 8.79 | 16.99 | 5.29 | 40.00 | 16.73 | 23.92 | 6.99 | ||
Fluoroscopy time (min | 12.49 | 5.27 | 11.23 | 3.61 | 22.68 | 7.98 | 14.87 | 5.10 | ||
Total time of series (min) | 1.99 | 0.84 | 1.79 | 0.76 | 1.84 | 0.79 | 1.67 | 0.80 | ||
Contrast agent (ml) | 54.05 | 22.41 | 49.62 | 20.20 | 75.82 | 34.14 | 58.58 | 24.75 | ||
| Number of series | 17 | 9 | 16 | 12 | 17 | 6 | 16 | 11 | ||
| Number of material changes | 1 | 1 | 1 | 2 | 2 | 2 | 1.5 | 1 | ||
| – | ||||||||||
| Mental demand | 10 | 9 | 10 | 8 | 11.5 | 9 | 10 | 6 | ||
| Physical demand | 4 | 4 | 5 | 6 | 4 | 2 | 5.5 | 5 | ||
| Temporal demand | 8 | 8 | 7 | 7 | 6.5 | 7 | 6 | 5 | ||
| Satisfaction with performance | 17 | 2 | 16 | 4 | 13.5 | 6 | 16 | 2 | ||
| Effort | 11.5 | 7 | 11 | 6 | 15.5 | 3 | 13.5 | 5 | ||
| Frustration | 5.5 | 5 | 7 | 3 | 5 | 7 | 4 | 5 | ||
| Heart rate (bpm) | 78.06 | 7.74 | 80.14 | 10.25 | 84.07 | 14.88 | 78.86 | 12.47 | ||
| Viewing direction (%)a | 27.47 | 12.00 | 31.68 | 16.69 | 31.55 | 18.31 | 28.60 | 9.70 | ||
Median and IQR for number of series, number of material changes and results of NASA-TLX, p-values of mediantest <0.05 are in bold type. Mean for total duration, fluoroscopy time, total time of series and amount of contrast agent, heart rate and gaze direction, p-values of Mann Whitney-U-Test <0.05 are in bold type
aPercentage of deviation of more than 30° from the horizontal view downwards.
Fig. 2Fluoroscopy time of beginners (red) and experts (blue) with corresponding regression line during all 10 simulations. Cases 1, 4 and 5 are repeated (in same order) in cases 6, 9 and 10 respectively
Comparison of experts and beginners regarding unknown and known cases
| Experts ( | Beginners ( | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Unknown | Known cases | Unknown | Known cases | |||||||
| – | ||||||||||
Total duration (min | 20.90 | 8.42 | 16.34 | 4.19 | 35.91 | 16.03 | 22.73 | 6.37 | ||
Fluoroscopy time (min) | 12.36 | 5.03 | 10.71 | 2.98 | 20.66 | 7.90 | 14.39 | 5.19 | ||
Total time of series (min) | 1.93 | 0.83 | 1.83 | 074 | 1.81 | 0.78 | 1.64 | 0.82 | ||
Contrast agent (ml) | 52.84 | 22.04 | 49.89 | 19.98 | 71.95 | 30.90 | 56.12 | 28.43 | ||
| Number of series | 17 | 12 | 16 | 7 | 17 | 7 | 16 | 11 | ||
| Number of material changes | 1 | 1 | 1 | 2 | 2 | 2 | 1 | 1 | ||
| Mental demand | 10 | 9 | 8 | 8 | 11.5 | 9 | 8 | 6 | ||
| Physical demand | 4 | 4 | 5 | 6 | 5 | 4 | 5 | 4 | ||
| Temporal demand | 8 | 7 | 7 | 7 | 6.5 | 7 | 6 | 5 | ||
| Satisfaction with performance | 17 | 3 | 15.5 | 4 | 14 | 6 | 16 | 2 | ||
| Effort | 12.5 | 5 | 9.5 | 6 | 15.5 | 3 | 13 | 7 | ||
| Frustration | 6 | 5 | 6.5 | 2 | 5 | 8 | 4 | 3 | ||
| Heart rate (bpm) | 78.77 | 8.41 | 79.61 | 10.54 | 82.4 | 14.30 | 79.09 | 12.85 | ||
| Viewing direction (%)a | 27.75 | 13.36 | 33.73 | 16.38 | 30.79 | 16.43 | 28.41 | 9.23 | ||
Median and IQR for number of series, number of material changes and results of NASA-TLX, p-values of median test <0.05 are in bold type. Mean for total duration, fluoroscopy time, total time of series and amount of contrast agent, heart rate and gaze direction, p-values of Mann Whitney U‑test <0.05 are in bold type
aPercentage of deviation of more than 30° from the horizontal view downwards