Personalized Rate-Response Programming Improves Exercise Tolerance After 6 Months in People With Cardiac Implantable Electronic Devices and Heart Failure: A Phase II Study.

John Gierula1, Judith E Lowry1, Maria F Paton1, Charlotte A Cole1, Rowenna Byrom1, Aaron O Koshy1, Hemant Chumun1, Lorraine C Kearney1, Sam Straw1, T Scott Bowen2, Richard M Cubbon1, Anne-Maree Keenan3, Deborah D Stocken4, Mark T Kearney1, Klaus K Witte1.   

Abstract

BACKGROUND: Heart failure with reduced ejection fraction (HFrEF) is characterized by blunting of the positive relationship between heart rate and left ventricular (LV) contractility known as the force-frequency relationship (FFR). We have previously described that tailoring the rate-response programming of cardiac implantable electronic devices in patients with HFrEF on the basis of individual noninvasive FFR data acutely improves exercise capacity. We aimed to examine whether using FFR data to tailor heart rate response in patients with HFrEF with cardiac implantable electronic devices favorably influences exercise capacity and LV function 6 months later.
METHODS: We conducted a single-center, double-blind, randomized, parallel-group trial in patients with stable symptomatic HFrEF taking optimal guideline-directed medical therapy and with a cardiac implantable electronic device (cardiac resynchronization therapy or implantable cardioverter-defibrillator). Participants were randomized on a 1:1 basis between tailored rate-response programming on the basis of individual FFR data and conventional age-guided rate-response programming. The primary outcome measure was change in walk time on a treadmill walk test. Secondary outcomes included changes in LV systolic function, peak oxygen consumption, and quality of life.
RESULTS: We randomized 83 patients with a mean±SD age 74.6±8.7 years and LV ejection fraction 35.2±10.5. Mean change in exercise time at 6 months was 75.4 (95% CI, 23.4 to 127.5) seconds for FFR-guided rate-adaptive pacing and 3.1 (95% CI, -44.1 to 50.3) seconds for conventional settings (analysis of covariance; P=0.044 between groups) despite lower peak mean±SD heart rates (98.6±19.4 versus 112.0±20.3 beats per minute). FFR-guided heart rate settings had no adverse effect on LV structure or function, whereas conventional settings were associated with a reduction in LV ejection fraction.
CONCLUSIONS: In this phase II study, FFR-guided rate-response programming determined using a reproducible, noninvasive method appears to improve exercise time and limit changes to LV function in people with HFrEF and cardiac implantable electronic devices. Work is ongoing to confirm our findings in a multicenter setting and on longer-term clinical outcomes. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02964650.

Entities:  

Keywords:  exercise; heart failure; heart rate

Year:  2020        PMID: 32299222     DOI: 10.1161/CIRCULATIONAHA.119.045066

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  1 in total

Review 1.  Rate adaptive pacing in people with chronic heart failure increases peak heart rate but not peak exercise capacity: a systematic review.

Authors:  H I Clark; M J Pearson; N A Smart
Journal:  Heart Fail Rev       Date:  2022-02-09       Impact factor: 4.214

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.