Literature DB >> 32291979

[A comparative study of Taylor spatial frame and unilateral external fixator in treatment of tibiofibular open fractures].

He Ma1, Hui Yao1, Tao Zhang1, Chunyou Wan1.   

Abstract

OBJECTIVE: To compare the effectiveness of Taylor spatial frame (TSF) and unilateral external fixator in the treatment of tibiofibular open fractures.
METHODS: Between January 2016 and July 2018, 74 patients with tibiofibular open fracture who met the selection criteria were divided into TSF group (43 cases, fixed with TSF) and unilateral group (31 cases, fixed with unilateral external fixator) according to the principle of entering the group every other day. There was no significant difference in gender, age, affected side, cause of injury, type of fracture between the two groups ( P>0.05). The operation time, fracture healing time, removal time of external fixator, and complications were recorded and compared between the two groups. The limb function was evaluated according to Johner-Wruhs criteria for evaluating the final effectiveness of tibial shaft fracture treatment. The recovery of lower limb force line was ecaluated by LUO Congfeng et al. criteria.
RESULTS: All patients were followed up 8-22 months, with a median of 12 months. All fractures healed, and no complication such as delayed union, nonunion, or osteomyelitis occurred. The operation time, fracture healing time, and removal time of external fixator in TSF group were significantly shorter than those in unilateral group ( P<0.05). At 3 months after the removal of the external fixator, the limb function was evaluated according to the Johner-Wruhs standard. In TSF group, 41 cases were excellent, 1 case was good, and 1 case was fair, and the excellent and good rate was 97.67%; in unilateral group, 30 cases were excellent and 1 case was fair, and the excellent and good rate was 96.77%; there was no significant difference between the two groups ( P=0.666). At 4 months after operation, the recovery of lower limb force line was ecaluated by LUO Congfeng et al. criterion. In TSF group, 41 cases were excellent, 2 cases were good, and 1 case was fair, and the excellent and good rate was 97.67%; in unilateral group, 29 cases were excellent, 1 case was good, 1 case was fair, and the excellent and good rate was 96.77%; there was no significant difference between the two groups ( P=0.666).
CONCLUSION: For tibiofibular open fracture, on the premise of fracture healing, TSF technology is superior to unilateral external fixation in terms of shortening operation time, fracture healing time, and removal time of external fixator.

Entities:  

Keywords:  Taylor spatial frame; external fixation; tibiofibular open fracture; unilateral external fixator

Mesh:

Year:  2020        PMID: 32291979      PMCID: PMC8171500          DOI: 10.7507/1002-1892.201909120

Source DB:  PubMed          Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi        ISSN: 1002-1892


  10 in total

1.  In vivo assessment of regenerate axial stiffness in distraction osteogenesis.

Authors:  Gudrun Trøite Aarnes; Harald Steen; Per Ludvigsen; Nicholas A Waanders; Rik Huiskes; Steven A Goldstein
Journal:  J Orthop Res       Date:  2005-03       Impact factor: 3.494

2.  [Correction of posttraumatic lower leg deformities using the Taylor Spatial Frame].

Authors:  D Krappinger; M Zegg; V Smekal; B Huber
Journal:  Oper Orthop Traumatol       Date:  2014-10       Impact factor: 1.154

3.  [Application of Taylor spatial frame combined with computer-assisted closed reduction in the treatment of tibiofibular fractures].

Authors:  Qihang Ge; Chunyou Wan; Xing Shao; Tao Zhang; Peng Jia; Xiaolong Mei; Mingjie Wang; Yuanhang Zhao; Qingsong Pan; Jihai Ma
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2019-02-15

4.  Simple external fixation of open and complicated fractures.

Authors:  S R Cannon; A R Taylor; A R Lynch
Journal:  Injury       Date:  1985-05       Impact factor: 2.586

5.  The use of the taylor spatial frame for the treatment of unstable tibial fractures in children.

Authors:  Michalis Zenios
Journal:  J Orthop Trauma       Date:  2013-10       Impact factor: 2.512

Review 6.  New technologies for the enhancement of skeletal repair.

Authors:  T William Axelrad; Sanjeev Kakar; Thomas A Einhorn
Journal:  Injury       Date:  2007-03       Impact factor: 2.586

7.  Taylor spatial frame fixation in patients with multiple traumatic injuries: study of 57 long-bone fractures.

Authors:  Francesco Sala; Yasser Elbatrawy; Ahmed M Thabet; Mahmoud Zayed; Dario Capitani
Journal:  J Orthop Trauma       Date:  2013-08       Impact factor: 2.512

8.  Patient specific finite element analysis results in more accurate prediction of stent fractures: application to percutaneous pulmonary valve implantation.

Authors:  Silvia Schievano; Andrew M Taylor; Claudio Capelli; Philipp Lurz; Johannes Nordmeyer; Francesco Migliavacca; Philipp Bonhoeffer
Journal:  J Biomech       Date:  2009-11-06       Impact factor: 2.712

9.  Accuracy of complex lower-limb deformity correction with external fixation: a comparison of the Taylor Spatial Frame with the Ilizarov ring fixator.

Authors:  Hans Michael Manner; Michael Huebl; Christof Radler; Rudolf Ganger; Gert Petje; Franz Grill
Journal:  J Child Orthop       Date:  2006-12-30       Impact factor: 1.548

10.  Conversion of open tibial IIIb to IIIa fractures using intentional temporary deformation and the Taylor Spatial Frame.

Authors:  H Sharma; T Nunn
Journal:  Strategies Trauma Limb Reconstr       Date:  2013-04-21
  10 in total
  1 in total

1.  [Clinical application of nose ring drain technique combined with Ilizarov circular external fixation for Gustilo ⅢA Pilon fractures].

Authors:  Shaoquan Pu; Yongqing Xu; Qian Lü; Zhineng Liu; Yonghui Zhao; Zeyu Zhao; Shen Xia; Xin Qi; Long Qu; Yueliang Zhu
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2021-02-15
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.