Michael R Pinsky1, Anthony Wertz2, Gilles Clermont1, Artur Dubrawski2. 1. From the University of Pittsburgh, School of Medicine, Pittsburgh, Pennsylvania. 2. Carnegie Mellon University, School of Computer Science, Auton Lab, Pittsburgh, Pennsylvania.
Abstract
BACKGROUND: Individualized hemodynamic monitoring approaches are not well validated. Thus, we evaluated the discriminative performance improvement that might occur when moving from noninvasive monitoring (NIM) to invasive monitoring and with increasing levels of featurization associated with increasing sampling frequency and referencing to a stable baseline to identify bleeding during surgery in a porcine model. METHODS: We collected physiologic waveform (WF) data (250 Hz) from NIM, central venous (CVC), arterial (ART), and pulmonary arterial (PAC) catheters, plus mixed venous O2 saturation and cardiac output from 38 anesthetized Yorkshire pigs bled at 20 mL/min until a mean arterial pressure of 30 mm Hg following a 30-minute baseline period. Prebleed physiologic data defined a personal stable baseline for each subject independently. Nested models were evaluated using simple hemodynamic metrics (SM) averaged over 20-second windows and sampled every minute, beat to beat (B2B), and WF using Random Forest Classification models to identify bleeding with or without normalization to personal stable baseline, using a leave-one-pig-out cross-validation to minimize model overfitting. Model hyperparameters were tuned to detect stable or bleeding states. Bleeding models were compared use both each subject's personal baseline and a grouped-average (universal) baseline. Timeliness of bleed onset detection was evaluated by comparing the tradeoff between a low false-positive rate (FPR) and shortest time to bleed detection. Predictive performance was evaluated using a variant of the receiver operating characteristic focusing on minimizing FPR and false-negative rates (FNR) for true-positive and true-negative rates, respectively. RESULTS: In general, referencing models to a personal baseline resulted in better bleed detection performance for all catheters than using universal baselined data. Increasing granularity from SM to B2B and WF progressively improved bleeding detection. All invasive monitoring outperformed NIM for both time to bleeding detection and low FPR and FNR. In that regard, when referenced to personal baseline with SM analysis, PAC and ART + PAC performed best; for B2B CVC, PAC and ART + PAC performed best; and for WF PAC, CVC, ART + CVC, and ART + PAC performed equally well and better than other monitoring approaches. Without personal baseline, NIM performed poorly at all levels, while all catheters performed similarly for SM, with B2B PAC and ART + PAC performing the best, and for WF PAC, ART, ART + CVC, and ART + PAC performed equally well and better than the other monitoring approaches. CONCLUSIONS: Increasing hemodynamic monitoring featurization by increasing sampling frequency and referencing to personal baseline markedly improves the ability of invasive monitoring to detect bleed.
BACKGROUND: Individualized hemodynamic monitoring approaches are not well validated. Thus, we evaluated the discriminative performance improvement that might occur when moving from noninvasive monitoring (NIM) to invasive monitoring and with increasing levels of featurization associated with increasing sampling frequency and referencing to a stable baseline to identify bleeding during surgery in a porcine model. METHODS: We collected physiologic waveform (WF) data (250 Hz) from NIM, central venous (CVC), arterial (ART), and pulmonary arterial (PAC) catheters, plus mixed venous O2 saturation and cardiac output from 38 anesthetized Yorkshire pigs bled at 20 mL/min until a mean arterial pressure of 30 mm Hg following a 30-minute baseline period. Prebleed physiologic data defined a personal stable baseline for each subject independently. Nested models were evaluated using simple hemodynamic metrics (SM) averaged over 20-second windows and sampled every minute, beat to beat (B2B), and WF using Random Forest Classification models to identify bleeding with or without normalization to personal stable baseline, using a leave-one-pig-out cross-validation to minimize model overfitting. Model hyperparameters were tuned to detect stable or bleeding states. Bleeding models were compared use both each subject's personal baseline and a grouped-average (universal) baseline. Timeliness of bleed onset detection was evaluated by comparing the tradeoff between a low false-positive rate (FPR) and shortest time to bleed detection. Predictive performance was evaluated using a variant of the receiver operating characteristic focusing on minimizing FPR and false-negative rates (FNR) for true-positive and true-negative rates, respectively. RESULTS: In general, referencing models to a personal baseline resulted in better bleed detection performance for all catheters than using universal baselined data. Increasing granularity from SM to B2B and WF progressively improved bleeding detection. All invasive monitoring outperformed NIM for both time to bleeding detection and low FPR and FNR. In that regard, when referenced to personal baseline with SM analysis, PAC and ART + PAC performed best; for B2B CVC, PAC and ART + PAC performed best; and for WF PAC, CVC, ART + CVC, and ART + PAC performed equally well and better than other monitoring approaches. Without personal baseline, NIM performed poorly at all levels, while all catheters performed similarly for SM, with B2B PAC and ART + PAC performing the best, and for WF PAC, ART, ART + CVC, and ART + PAC performed equally well and better than the other monitoring approaches. CONCLUSIONS: Increasing hemodynamic monitoring featurization by increasing sampling frequency and referencing to personal baseline markedly improves the ability of invasive monitoring to detect bleed.
Authors: Michael Walsh; Philip J Devereaux; Amit X Garg; Andrea Kurz; Alparslan Turan; Reitze N Rodseth; Jacek Cywinski; Lehana Thabane; Daniel I Sessler Journal: Anesthesiology Date: 2013-09 Impact factor: 7.892
Authors: Matthias S Goepfert; Hans Peter Richter; Christine Zu Eulenburg; Janna Gruetzmacher; Erik Rafflenbeul; Katharina Roeher; Alexandra von Sandersleben; Stefan Diedrichs; Herrmann Reichenspurner; Alwin E Goetz; Daniel A Reuter Journal: Anesthesiology Date: 2013-10 Impact factor: 7.892
Authors: Maurizio Cecconi; Christoph Hofer; Jean-Louis Teboul; Ville Pettila; Erika Wilkman; Zsolt Molnar; Giorgio Della Rocca; Cesar Aldecoa; Antonio Artigas; Sameer Jog; Michael Sander; Claudia Spies; Jean-Yves Lefrant; Daniel De Backer Journal: Intensive Care Med Date: 2015-07-11 Impact factor: 17.440
Authors: Joseph M Bednarczyk; Jason A Fridfinnson; Anand Kumar; Laurie Blanchard; Rasheda Rabbani; Dean Bell; Duane Funk; Alexis F Turgeon; Ahmed M Abou-Setta; Ryan Zarychanski Journal: Crit Care Med Date: 2017-09 Impact factor: 7.598
Authors: Kamal Maheshwari; Brian H Nathanson; Sibyl H Munson; Victor Khangulov; Mitali Stevens; Hussain Badani; Ashish K Khanna; Daniel I Sessler Journal: Intensive Care Med Date: 2018-06-05 Impact factor: 17.440