Literature DB >> 32285115

INVESTIGATION OF THE INFLUENCE OF THYROID LOCATION ON IODINE-131 S VALUES.

Yeon Soo Yeom1, Daphnée Villoing1, Natasha Greenstein2, Cari M Kitahara1, Les R Folio3, Chan Hyeong Kim4, Choonsik Lee1.   

Abstract

The use of iodine-131 S values based on reference computational phantoms with fixed thyroid model may lead to significant dosimetric errors in patients who may have different thyroid location from the reference phantoms. In the present study, we investigated individual thyroid location variation by examining the computed tomography image sets of 40 adult male and female patients. Subsequently, the thyroid location of the adult male and female mesh-type reference phantoms of the International Commission on Radiological Protection (ICRP) was adjusted to match each the highest, mean and the lowest locations of the thyroid observed in this dataset. The thyroid-adjusted phantoms were implemented into the Geant4 Monte Carlo code to calculate thyroid location-dependent iodine-131 S values (rT ← thyroid) for a total of 30 target regions. The maximum variation among the observed thyroid locations was 39 mm and 36 mm for male and female patients, respectively. The mean thyroid locations of both male and female patients showed a good agreement with the ICRP reference phantoms. The thyroid location-dependent Iodine-131 S values were significantly different from the reference phantoms for most target regions by up to a factor of 3. The use of thyroid location-dependent S values in dose reconstructions should help quantify the dosimetric uncertainty in epidemiologic investigations of patients receiving iodine-131 therapy for hyperthyroidism and thyroid cancer.
© The Author(s) 2020. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Entities:  

Mesh:

Substances:

Year:  2020        PMID: 32285115      PMCID: PMC7357322          DOI: 10.1093/rpd/ncaa027

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  18 in total

1.  Procedure guideline for therapy of thyroid disease with (131)iodine.

Authors:  Donald A Meier; David R Brill; David V Becker; Susan E M Clarke; Edward B Silberstein; Henry D Royal; Helena R Balon
Journal:  J Nucl Med       Date:  2002-06       Impact factor: 10.057

2.  Response functions for computing absorbed dose to skeletal tissues from photon irradiation--an update.

Authors:  Perry B Johnson; Amir A Bahadori; Keith F Eckerman; Choonsik Lee; Wesley E Bolch
Journal:  Phys Med Biol       Date:  2011-03-22       Impact factor: 3.609

3.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103.

Authors: 
Journal:  Ann ICRP       Date:  2007

4.  MIRD pamphlet No. 21: a generalized schema for radiopharmaceutical dosimetry--standardization of nomenclature.

Authors:  Wesley E Bolch; Keith F Eckerman; George Sgouros; Stephen R Thomas
Journal:  J Nucl Med       Date:  2009-03       Impact factor: 10.057

5.  ICRP Publication 107. Nuclear decay data for dosimetric calculations.

Authors:  K Eckerman; A Endo
Journal:  Ann ICRP       Date:  2008

6.  S values for 131I based on the ICRP adult voxel phantoms.

Authors:  Stephanie Lamart; Steven L Simon; Andre Bouville; Brian E Moroz; Choonsik Lee
Journal:  Radiat Prot Dosimetry       Date:  2015-03-31       Impact factor: 0.972

7.  Development of skeletal system for mesh-type ICRP reference adult phantoms.

Authors:  Yeon Soo Yeom; Zhao Jun Wang; Thang Tat Nguyen; Han Sung Kim; Chansoo Choi; Min Cheol Han; Chan Hyeong Kim; Jai Ki Lee; Beom Sun Chung; Maria Zankl; Nina Petoussi-Henss; Wesley E Bolch; Choonsik Lee
Journal:  Phys Med Biol       Date:  2016-09-20       Impact factor: 3.609

8.  Comparison of internal dosimetry factors for three classes of adult computational phantoms with emphasis on I-131 in the thyroid.

Authors:  Stephanie Lamart; Andre Bouville; Steven L Simon; Keith F Eckerman; Dunstana Melo; Choonsik Lee
Journal:  Phys Med Biol       Date:  2011-11-21       Impact factor: 3.609

9.  Basic anatomical and physiological data for use in radiological protection: reference values. A report of age- and gender-related differences in the anatomical and physiological characteristics of reference individuals. ICRP Publication 89.

Authors: 
Journal:  Ann ICRP       Date:  2002

10.  An analysis of "ablation of thyroid remnants" with I-131 in 511 patients from 1947-1984: experience at University of Michigan.

Authors:  W H Beierwaltes; R Rabbani; C Dmuchowski; R V Lloyd; P Eyre; S Mallette
Journal:  J Nucl Med       Date:  1984-12       Impact factor: 10.057

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.