Literature DB >> 32279436

Total keratometry in intraocular lens power calculations in eyes with previous laser refractive surgery.

Michael Lawless1,2, James Y Jiang3, Chris Hodge1,2,4, Gerard Sutton1,2, Timothy V Roberts1,2, Graham Barrett5,6,7.   

Abstract

IMPORTANCE: Intraocular lens (IOL) calculations in post-refractive cases remain a concern. Our study identifies improved options for surgeons.
BACKGROUND: To evaluate and compare the prediction accuracy of IOL power calculation methods after previous laser refractive surgery using standard keratometry (SK), measured posterior corneal astigmatism (PCA) and total keratometry (TK).
DESIGN: Retrospective consecutive cohort. PARTICIPANTS: A total of 50 consecutive patients (72 eyes) at a private institution who underwent cataract surgery with prior laser refractive procedures.
METHODS: Methods using SK included ASCRS mean, Barrett True-K no history, Haigis-L and Shammas IOL formulae. Barrett True-K using posterior values (True K TK), Haigis and Holladay 1 Double-K methods using TK were also assessed. Post-surgery refraction was undertaken at minimum 3 weeks following surgery. MAIN OUTCOME MEASURES: Arithmetic and absolute IOL refractive prediction errors, variances in mean arithmetic IOL prediction error, and percentage of eyes within ±0.25D, ±0.50D, ±0.75D and ±1.00D of refractive prediction errors were compared.
RESULTS: The Barrett True-K (TK) provided the lowest mean refractive prediction error (RPE) and variance for both prior myopes and hyperopes undergoing cataract surgery. The Barrett True-K (TK) exhibited the highest percentages of eyes within ±0.50D, ±0.75D and ±1.00D of the RPE compared to other formulae for prior myopic patients. CONCLUSIONS AND RELEVANCE: Accuracy of IOL power calculations in post-laser eyes can be improved by the addition of posterior corneal values as measured by the IOLMaster 700. The use of total keratometry may supplement outcomes when no prior refraction history is known.
© 2020 Royal Australian and New Zealand College of Ophthalmologists.

Entities:  

Keywords:  cataract; intraocular lens; refractive surgery; surgery

Year:  2020        PMID: 32279436     DOI: 10.1111/ceo.13760

Source DB:  PubMed          Journal:  Clin Exp Ophthalmol        ISSN: 1442-6404            Impact factor:   4.207


  13 in total

1.  Lower refractive prediction accuracy of total keratometry using intraocular lens formulas loaded onto a swept-source optical biometer.

Authors:  Yukitaka Danjo; Reina Ohji; Sayo Maeno
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2022-07-26       Impact factor: 3.535

2.  Predictability of pseudophakic refraction using patient-customized paraxial eye models.

Authors:  Yu-Cherng Chang; Florence Cabot; Bianca Maceo Heilman; Larissa Meza; Marco Ruggeri; Arthur Ho; Sonia H Yoo; Jean-Marie Parel; Fabrice Manns
Journal:  J Cataract Refract Surg       Date:  2022-09-01       Impact factor: 3.528

3.  Comparison of ocular biometric measurements in patients with cataract using three swept-source optical coherence tomography devices.

Authors:  Richul Oh; Joo Youn Oh; Hyuk Jin Choi; Mee Kum Kim; Chang Ho Yoon
Journal:  BMC Ophthalmol       Date:  2021-01-27       Impact factor: 2.209

4.  Refractive Precision of Ray Tracing IOL Calculations Based on OCT Data versus Traditional IOL Calculation Formulas Based on Reflectometry in Patients with a History of Laser Vision Correction for Myopia.

Authors:  Bjørn Gjerdrum; Kjell Gunnar Gundersen; Per Olof Lundmark; Bente Monica Aakre
Journal:  Clin Ophthalmol       Date:  2021-02-26

5.  Prediction accuracy of standard and total keratometry by swept-source optical biometer for multifocal intraocular lens power calculation.

Authors:  Hun Lee; Jae Lim Chung; Young Jun Kim; Jae Yong Kim; Hungwon Tchah
Journal:  Sci Rep       Date:  2021-02-26       Impact factor: 4.379

6.  A Multicenter Study of the Distribution Pattern of Posterior-To-Anterior Corneal Curvature Radii Ratio in Chinese Myopic Patients.

Authors:  Changting Tang; Qiaowei Wu; Baoyi Liu; Guanrong Wu; Jing Fan; Yijun Hu; Honghua Yu
Journal:  Front Med (Lausanne)       Date:  2021-12-20

7.  Factors affecting prediction error after cataract surgery with implantation of various multifocal IOLs in patients with previous refractive laser surgery.

Authors:  Young-Sik Yoo; Min Chae Kang; Jongyeop Park; Hyung-Goo Kwon; Eui-Sang Chung; Dong Hui Lim; Tae-Young Chung
Journal:  Ann Transl Med       Date:  2021-12

Review 8.  Intraocular lens power calculations in eyes with previous corneal refractive surgery: Challenges, approaches, and outcomes.

Authors:  Li Wang; Douglas D Koch
Journal:  Taiwan J Ophthalmol       Date:  2021-10-20

9.  Acquisition Time for Swept-Source Optical Biometry Plus Corneal Power Measurement During Cataract Evaluation.

Authors:  Ramón Ruiz-Mesa; Maria Ruiz-Santos; Julia Blanch-Ruiz; Ana Jiménez-Nieto
Journal:  Clin Ophthalmol       Date:  2022-03-05

10.  Comparing prediction accuracy between total keratometry and conventional keratometry in cataract surgery with refractive multifocal intraocular lens implantation.

Authors:  Ho Seok Chung; Jae Lim Chung; Young Jun Kim; Hun Lee; Jae Yong Kim; Hungwon Tchah
Journal:  Sci Rep       Date:  2021-09-28       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.