Lighting condition is essential to human performance. With the widespread use of computer-based learning, the performance measurements become difficult, and the effects of artificial lighting conditions towards the new learning forms are not investigated extensively. The current study conducts a subject-within experiment with a 45-min-long online learning along with electroencephalogram (EEG)-based measurements, and a post-interview under five lighting setups respectively (300 lx, 3000 K; 300 lx, 4000 K; 300 lx, 6500 K; 500 lx, 4000 K; 1000 lx, 4000 K). Attention is chosen as the key factor to represent the learning performance. The results show that the attention of people aged in the 20s is not affected by the experimental lighting conditions. The results also demonstrate that people in high illumination at 1000 lx are more inclined to sustain attention despite the discomfort and dissatisfaction. Taking the EEG-based attention measurements and post-interview answers into consideration, lighting conditions at 300 lx, 4000 K are the recommended set points for university architectures among the investigated conditions, providing a practical basis when adjusting the lighting standard for its advantage in energy saving.Entities:
Keywords: EEG measurement; attention status; learning efficiency; lighting conditions
Year: 2020 PMID: 32276306 PMCID: PMC7177684 DOI: 10.3390/ijerph17072537
Source DB: PubMed Journal: Int J Environ Res Public Health ISSN: 1660-4601 Impact factor: 3.390
Lighting setups in the experiments.
| No. | Lighting Setup | Set Points | Actual Value |
|---|---|---|---|
| 1 | dim, warm | 300 lx, 3000 K | 307 lx, 3122 K |
| 2 | dim, white | 300 lx, 4000 K | 308 lx, 4180 K |
| 3 | dim, cold | 300 lx, 6500 K | 308 lx, 6415 K |
| 4 | neutral, white | 500 lx, 4000 K | 502 lx, 4180 K |
| 5 | light, white | 1000 lx, 4000 K | 1005 lx, 4180 K |
Figure 1Fluorescent tubes setup.
Figure 2International 10–20 system of electrode placement.
Statements in the interview.
| No. | Statements |
|---|---|
| 1 | I feel comfortable about the present lighting condition |
| 2 | I feel exhausted under the present lighting condition |
| 3 | I can concentrate for a continuous work for another 15 min |
| 4 | I am satisfied with the present lighting condition during learning |
Figure 3Attention status under different illumination conditions.
Significance difference test results under various illumination conditions.
| Segments | 300 lx–500 lx | 500 lx–1000 lx |
|---|---|---|
| 1st | 0.401 | 0.09 |
| 2nd | 0.779 | 0.499 |
| 3rd | 0.123 | 0.398 |
| 4th | 0.575 | 0.237 |
| 5th | 0.327 | 0.612 |
| 6th | 0.779 | 0.237 |
| 7th | 0.779 | 0.091 |
| 8th | 0.484 | 0.499 |
| 9th | 0.889 | 0.237 |
| 45-min average EEG | 0.889 | 0.31 |
Figure 4Attention status under different color temperature conditions.
Significance difference test results under different color temperature conditions.
| Segments | 3000 K–4000 K | 4000 K–6500 K |
|---|---|---|
| 1st | 0.889 | 0.575 |
| 2nd | 0.263 | 0.674 |
| 3rd | 0.674 | 0.263 |
| 4th | 0.263 | 0.484 |
| 5th | 0.401 | 0.575 |
| 6th | 0.575 | 0.401 |
| 7th | 0.889 | 0.889 |
| 8th | 0.674 | 0.889 |
| 9th | 0.866 | 0.889 |
| 45-min average EEG | 0.674 | 0.575 |
Figure 5Voting scores and EEG values under different lighting conditions.