BACKGROUND: Optimal treatment of displaced proximal humeral fractures is controversial. This retrospective study aims to identify complications and clinical outcomes using a locking plate with smooth pegs instead of screws (S3 plate). METHOD: Eighty-two patients with displaced proximal humeral fracture classified with 2-4 fragments (Neer's classification) treated with open reduction and internal fixation (ORIF) with S3 plate were studied retrospectively. Clinical outcome according to constant score; Single Shoulder Value; Disabilities of Arm, Shoulder and Hand; and European Quality of life-5 dimensions and complication rate defined radiologically including peg penetration, avascular necrosis, and loss of reduction was assessed minimum 2.5 years after surgery. RESULTS: A total of 11 peg penetrations were identified (13.6%). Avascular necrosis was seen in 8.5% (n = 7). Mean constant score at follow-up was 64.4 with a relative constant score of 87% (standard deviation 18%) compared to the contralateral uninjured side. The mean Disabilities of Arm, Shoulder and Hand score was 12.7 and mean European Quality of life-5 dimensions score 0.83. The mean Single Shoulder Value was 78.3. No cases of deep infection were seen. CONCLUSIONS: Fixation with S3 plate shows a proper osteosynthesis and the functional outcome is good. Symptomatic peg penetrations are rare and the incidence is lower compared to what has been reported with locked screws.
BACKGROUND: Optimal treatment of displaced proximal humeral fractures is controversial. This retrospective study aims to identify complications and clinical outcomes using a locking plate with smooth pegs instead of screws (S3 plate). METHOD: Eighty-two patients with displaced proximal humeral fracture classified with 2-4 fragments (Neer's classification) treated with open reduction and internal fixation (ORIF) with S3 plate were studied retrospectively. Clinical outcome according to constant score; Single Shoulder Value; Disabilities of Arm, Shoulder and Hand; and European Quality of life-5 dimensions and complication rate defined radiologically including peg penetration, avascular necrosis, and loss of reduction was assessed minimum 2.5 years after surgery. RESULTS: A total of 11 peg penetrations were identified (13.6%). Avascular necrosis was seen in 8.5% (n = 7). Mean constant score at follow-up was 64.4 with a relative constant score of 87% (standard deviation 18%) compared to the contralateral uninjured side. The mean Disabilities of Arm, Shoulder and Hand score was 12.7 and mean European Quality of life-5 dimensions score 0.83. The mean Single Shoulder Value was 78.3. No cases of deep infection were seen. CONCLUSIONS: Fixation with S3 plate shows a proper osteosynthesis and the functional outcome is good. Symptomatic peg penetrations are rare and the incidence is lower compared to what has been reported with locked screws.
Authors: Christopher R Constant; Christian Gerber; Roger J H Emery; Jens Ole Søjbjerg; Frank Gohlke; Pascal Boileau Journal: J Shoulder Elbow Surg Date: 2008-01-22 Impact factor: 3.019
Authors: Dietmar Krappinger; Nicola Bizzotto; Stephan Riedmann; Christian Kammerlander; Clemens Hengg; Franz Sebastian Kralinger Journal: Injury Date: 2011-02-09 Impact factor: 2.586
Authors: Antti P Launonen; Vesa Lepola; Aino Saranko; Tapio Flinkkilä; Minna Laitinen; Ville M Mattila Journal: Arch Osteoporos Date: 2015-02-13 Impact factor: 2.617
Authors: Felix Brunner; Christoph Sommer; Christian Bahrs; Rainer Heuwinkel; Christian Hafner; Paavo Rillmann; Georges Kohut; Anders Ekelund; Mathias Muller; Laurent Audigé; Reto Babst Journal: J Orthop Trauma Date: 2009-03 Impact factor: 2.512
Authors: N Südkamp; J Bayer; P Hepp; C Voigt; H Oestern; M Kääb; C Luo; M Plecko; K Wendt; W Köstler; G Konrad Journal: J Bone Joint Surg Am Date: 2009-06 Impact factor: 5.284
Authors: Ingrid Bønes; Anna Cecilie Karlberg; Maria Liljeholm; Alexander Nilsskog Fraser; Jan Erik Madsen; Tore Fjalestad Journal: J Orthop Surg Res Date: 2022-02-02 Impact factor: 2.359