| Literature DB >> 32252816 |
Ziyong Wang1, Yunyun Shang2, Ting Luan1, Yi Duan2, Jiansong Wang1, Haifeng Wang3, Jingang Hao4.
Abstract
BACKGROUND: The Vesical Imaging-Reporting and Data System (VI-RADS) was created in 2018, and a 5-point VI-RADS scoring system was proposed to determine whether the muscularis of the bladder has been infiltrated by tumor tissues.Entities:
Keywords: Bladder cancer; Multiparameter magnetic resonance imaging; Reporting and data system; Scoring; Staging
Year: 2020 PMID: 32252816 PMCID: PMC7137481 DOI: 10.1186/s40644-020-00304-3
Source DB: PubMed Journal: Cancer Imaging ISSN: 1470-7330 Impact factor: 3.909
Fig. 1VI-RADS scoring rule schematic. CE = contrast enhanced; DW = diffusion weighted; SC = structural category; SI = signal intensity
Pathological stages corresponding to each image sequence score and VI-RADS scores in MIBC and NMIBC
| Image sequences and scores | Non-muscle invasive group | Muscle invasive group | |||||
|---|---|---|---|---|---|---|---|
| n | Ta | T1 | n | T2 | T3 | T4 | |
| T2WI | |||||||
| 1 | 25 | 3 | 22 | 0 | 0 | 0 | 0 |
| 2 | 42 | 0 | 42 | 3 | 3 | 0 | 0 |
| 3 | 37 | 0 | 37 | 23 | 23 | 0 | 0 |
| 4 | 3 | 0 | 3 | 21 | 20 | 1 | 0 |
| 5 | 0 | 0 | 0 | 66 | 10 | 52 | 4 |
| DCE | |||||||
| 1 | 25 | 3 | 22 | 0 | 0 | 0 | 0 |
| 2 | 58 | 0 | 58 | 3 | 3 | 0 | 0 |
| 3 | 19 | 0 | 19 | 18 | 18 | 0 | 0 |
| 4 | 5 | 0 | 5 | 31 | 31 | 0 | 0 |
| 5 | 0 | 0 | 0 | 61 | 4 | 53 | 4 |
| DWI | |||||||
| 1 | 25 | 3 | 22 | 0 | 0 | 0 | 0 |
| 2 | 60 | 0 | 60 | 3 | 3 | 0 | 0 |
| 3 | 17 | 0 | 17 | 18 | 18 | 0 | 0 |
| 4 | 5 | 0 | 5 | 30 | 30 | 0 | 0 |
| 5 | 0 | 0 | 0 | 62 | 5 | 53 | 4 |
| VI-RADS | |||||||
| 1 | 25 | 3 | 22 | 0 | 0 | 0 | 0 |
| 2 | 58 | 0 | 58 | 3 | 3 | 0 | 0 |
| 3 | 19 | 0 | 19 | 17 | 17 | 0 | 0 |
| 4 | 5 | 0 | 5 | 31 | 31 | 0 | 0 |
| 5 | 0 | 0 | 0 | 62 | 5 | 53 | 4 |
Fig. 2ROC curve for each image sequence score and VI-RADS score
The area under the ROC curve of each image sequence score and VI-RADS score
| Variate | Area | Standard error | 95% confidence intervals |
|---|---|---|---|
| T2WI | 0.941 | 0.014 | 0.913, 0.969 |
| DCE | 0.959 | 0.012 | 0.936, 0.982 |
| DWI | 0.961 | 0.011 | 0.938, 0.983 |
| VIRADS | 0.960 | 0.012 | 0.937, 0.983 |
Sensitivity and specificity of image sequence scores under different critical values
| Variate | Critical value | Sensibility | 1- specificity |
|---|---|---|---|
| T2WI | 2.50 | 0.973 | 0.374 |
| 3.50 | 0.770 | 0.028 | |
| DCE | 2.50 | 0.973 | 0.224 |
| 3.50 | 0.814 | 0.047 | |
| DWI | 2.50 | 0.973 | 0.206 |
| 3.50 | 0.814 | 0.047 | |
| VIRADS | 2.50 | 0.973 | 0.224 |
| 3.50 | 0.823 | 0.047 |
Fig. 3Image sequences of a single tumor with a score of VI-RADS 2 on the transverse plane. (a): T2-weighted imaging of tumors with a score of VI-RADS 2 on transverse plane; (b): Dynamic contrast enhanced imaging on transverse plane; (c)and(d): diffusion-weighted imaging on transverse plane
Fig. 4T2WI images of bladder tumors located around the ureter orifice on all scanning planes. a T2-weighted imaging of bladder tumor around the ureter orifice on the sagittal plane; b T2-weighted imaging on the coronal plane; c T2-weighted imaging on the transverse plane