Literature DB >> 32249183

Dosimetry, efficacy, and safety of three-dimensional printing noncoplanar template-assisted and CT-guided 125I seed implantation for recurrent retroperitoneal lymphatic metastasis after external beam radiotherapy.

Yi Chen1, Yuliang Jiang1, Zhe Ji1, Ping Jiang1, Fei Xu1, Yibao Zhang2, Pu Zhang3, Fuxing Guo1, Xuemin Li1, Haitao Sun1, Runhong Lei1, Jinghong Fan1, Weiyan Li1, Yuliang Huang2, Junjie Wang4.   

Abstract

OBJECTIVES: To evaluate the dosimetry, efficacy, and safety of radioactive 125I seed implantation (RISI) assisted by three-dimensional printing noncoplanar template (3D-PNCT) and CT for recurrent retroperitoneal lymphatic metastasis (RRLM) after previous external beam radiotherapy. METHODS AND MATERIALS: From June 2016 to August 2018, 32 patients with RRLM successfully underwent 3D-PNCT-assisted and CT-guided RISI. The dosimetry, pain relief rate, performance improvement rate, overall response rate, disease control rate, local control time (LCT), overall survival (OS), and safety profiles were evaluated.
RESULTS: Dosimetric results showed that the D90, D100, V100, V150, V200, and homogeneity index were consistent in preoperation and postoperation (p > 0.05), except for the external index and conformal index (p = 0.048, p = 0.034). After RISI, 81.3% of the patients achieved pain relief, and 71.9% achieved an improvement of performance. The overall response rate and disease control rate were 85.3% and 94.1%, respectively. The LCT rates reached 66.2% and 43.2% in 1 year and two years, respectively, with a median LCT of 15.8 months. The OS rates were 74.1% and 28.1% in 1 year and two year, respectively, with a median OS reaching 17.6 months. Univariate analysis showed that when D90 > 130 Gy or D100 > 63 Gy or tumor size ≤49.8 cm3, LCT was extended significantly, but not for OS. Except for two patients developing Grade 1 retroperitoneal hematomas, no other severe adverse events were observed.
CONCLUSIONS: 3D-PNCT and CT guidance provide excellent accuracy for RISI, which can be an effective and safe alternative for RRLM after external beam radiotherapy. Radiation dose and tumor size seem to significantly influence the local control.
Copyright © 2020 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Brachytherapy; CT-Guidance; Iodine-125; Recurrent cancer; Retroperitoneal lymphatic metastasis; Seed implantation; Three-dimensional printing template

Mesh:

Substances:

Year:  2020        PMID: 32249183     DOI: 10.1016/j.brachy.2020.02.009

Source DB:  PubMed          Journal:  Brachytherapy        ISSN: 1538-4721            Impact factor:   2.362


  4 in total

1.  3D-printed template and optical needle navigation in CT-guided iodine-125 permanent seed implantation.

Authors:  Zhe Ji; Yuliang Jiang; Haitao Sun; Yi Chen; Fuxin Guo; Jinghong Fan; Junjie Wang
Journal:  J Contemp Brachytherapy       Date:  2021-08-24

2.  Efficacy and safety of 3D printing coplanar template-assisted iodine-125 seed implantation as palliative treatment for inoperable pancreatic cancer.

Authors:  Baohu Wang; Bin Qiu; Linlin Wu; Yu'e Liu; Jingxian Zhang; Ruoyu Wang; Kaixian Zhang; Junjie Wang
Journal:  J Contemp Brachytherapy       Date:  2022-03-28

Review 3.  Re-Irradiation for Recurrent Cervical Cancer: A State-of-the-Art Review.

Authors:  Zongyan Shen; Ang Qu; Ping Jiang; Yuliang Jiang; Haitao Sun; Junjie Wang
Journal:  Curr Oncol       Date:  2022-07-25       Impact factor: 3.109

4.  The accuracy and dosimetric analysis of 3D-printing non-coplanar template-assisted iodine-125 seed implantation for recurrent chest wall cancer.

Authors:  Weijuan Jiang; Yi Chen; Zhe Ji; Yuliang Jiang; Bin Qiu; Haitao Sun; Junjie Wang
Journal:  J Contemp Brachytherapy       Date:  2021-05-18
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.