Literature DB >> 32235057

Biological washout modelling for in-beam PET: rabbit brain irradiation by 11C and 15O ion beams.

Chie Toramatsu1, Akram Mohammadi, Hidekazu Wakizaka, Chie Seki, Fumihiko Nishikido, Shinji Sato, Iwao Kanno, Miwako Takahashi, Kumiko Karasawa, Yoshiyuki Hirano, Taiga Yamaya.   

Abstract

Positron emission tomography (PET) has been used for dose verification in charged particle therapy. The causes of washout of positron emitters by physiological functions should be clarified for accurate dose verification. In this study, we visualized the distribution of irradiated radioactive beams, 11C and 15O beams, in the rabbit whole-body using our original depth-of-interaction (DOI)-PET prototype to add basic data for biological washout effect correction. Time activity curves of the irradiated field and organs were measured immediately after the irradiations. All data were corrected for physical decay before further analysis. We also collected expired gas of the rabbit during beam irradiation and the energy spectrum was measured with a germanium detector. Irradiated radioactive beams into the brain were distributed to the whole body due to the biological washout process, and the implanted 11C and 15O ions were concentrated in the regions which had high blood volume. The 11C-labelled 11CO2 was detected in expired gas under the 11C beam irradiation, while no significant signal was detected under the 15O beam irradiation as a form of C15O2. Results suggested that the implanted 11C ions form molecules that diffuse out to the whole body by undergoing perfusion, then, they are incorporated into the blood-gas exchange in the respiratory system. This study provides basic data for modelling of the biological washout effect.

Year:  2020        PMID: 32235057     DOI: 10.1088/1361-6560/ab8532

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  A proof-of-concept study of an in-situ partial-ring time-of-flight PET scanner for proton beam verification.

Authors:  Srilalan Krishnamoorthy; Boon-Keng K Teo; Wei Zou; James McDonough; Joel S Karp; Suleman Surti
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2020-12-14

2.  Visualisation of Range Shortening in Carbon Ion Beams and Washout of Positron Emitter: First-in-Human Report.

Authors:  Shintaro Shiba; Makoto Sakai; Masahiko Okamoto; Tatsuya Ohno
Journal:  In Vivo       Date:  2021 Nov-Dec       Impact factor: 2.155

3.  In vivo production of fluorine-18 in a chicken egg tumor model of breast cancer for proton therapy range verification.

Authors:  Samuel España; Daniel Sánchez-Parcerisa; Paloma Bragado; Álvaro Gutiérrez-Uzquiza; Almudena Porras; Carolina Gutiérrez-Neira; Andrea Espinosa; Víctor V Onecha; Paula Ibáñez; Víctor Sánchez-Tembleque; José M Udías; Luis M Fraile
Journal:  Sci Rep       Date:  2022-04-30       Impact factor: 4.996

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.