Literature DB >> 32233198

Accuracy of a Novel Trace-Registration Method for Dynamic Navigation Surgery.

Luigi V Stefanelli, George A Mandelaris, Bradley S DeGroot, Gianluca Gambarini, Francesca De Angelis, Stefano Di Carlo.   

Abstract

A technology called Trace Registration (TR) has been introduced to allow dynamic navigation of implant placement without the need for a thermoplastic stent. This study was undertaken in order to validate the accuracy of the TR protocol for dynamically guided implant surgery. A retrospective, observational, in vivo study was performed using dynamic navigation via the TR protocol. The preoperative cone beam computed tomography (CBCT) plan was superimposed and registered (aligned) with the postoperative CBCT scan to assess accuracy parameters. A total of 136 implants were placed in 59 partially edentulous arches. Mean deviation between the planned and actual position for all implants was 0.67 mm at the coronal level (entry point), 0.9 mm at the apical level, and 0.55 mm in depth, with an angle discrepancy of 2.50 degrees. Tracing 5 to 6 teeth tended to improve accuracy results compared to tracing 3 to 4 teeth. TR is as accurate as traditional registration and statically guided methods for implant surgery.

Year:  2020        PMID: 32233198     DOI: 10.11607/prd.4420

Source DB:  PubMed          Journal:  Int J Periodontics Restorative Dent        ISSN: 0198-7569            Impact factor:   1.840


  6 in total

1.  Clinical and radiological outcomes of novel digital workflow and dynamic navigation for single-implant immediate loading in aesthetic zone: 1-year prospective case series.

Authors:  Alessandro Pozzi; Lorenzo Arcuri; Paolo Carosi; Alessandra Nardi; Joseph Kan
Journal:  Clin Oral Implants Res       Date:  2021-09-08       Impact factor: 5.021

2.  Validation of an Intra-Oral Scan Method Versus Cone Beam Computed Tomography Superimposition to Assess the Accuracy between Planned and Achieved Dental Implants: A Randomized In Vitro Study.

Authors:  Alessio Franchina; Luigi V Stefanelli; Fabio Maltese; George A Mandelaris; Alessandro Vantaggiato; Michele Pagliarulo; Nicola Pranno; Edoardo Brauner; Francesca De Angelis; Stefano Di Carlo
Journal:  Int J Environ Res Public Health       Date:  2020-12-14       Impact factor: 3.390

3.  Digital Approach for the Rehabilitation of the Edentulous Maxilla with Pterygoid and Standard Implants: The Static and Dynamic Computer-Aided Protocols.

Authors:  Alessio Franchina; Luigi Vito Stefanelli; Simone Gorini; Simone Fedi; Giuseppe Lizio; Gerardo Pellegrino
Journal:  Methods Protoc       Date:  2020-12-21

4.  Does the macro design of an implant affect the accuracy of template-guided implantation? A prospective clinical study.

Authors:  Sigmar Schnutenhaus; Cornelia Edelmann; Heike Rudolph
Journal:  Int J Implant Dent       Date:  2021-04-26

5.  A registration-and-fixation approach with handpiece adjustment for dynamic navigation in dental implant surgery.

Authors:  Bin-Zhang Wu; Feng Sun
Journal:  Heliyon       Date:  2022-09-10

6.  A Novel Guided Zygomatic and Pterygoid Implant Surgery System: A Human Cadaver Study on Accuracy.

Authors:  Francesco Grecchi; Luigi V Stefanelli; Fabrizio Grivetto; Emma Grecchi; Rami Siev; Ziv Mazor; Massimo Del Fabbro; Nicola Pranno; Alessio Franchina; Vittorio Di Lucia; Francesca De Angelis; Funda Goker
Journal:  Int J Environ Res Public Health       Date:  2021-06-07       Impact factor: 3.390

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.