Literature DB >> 32218908

Hospital ventilation simulation for the study of potential exposure to contaminants.

Carla Balocco1.   

Abstract

Airflow and ventilation are particularly important in healthcare rooms for controlling thermo-hygrometric conditions, providing anaesthetic gas removal, diluting airborne bacterial contamination and minimizing bacteria transfer airborne. An actual hospitalization room was the investigate case study. Transient simulations with computational fluid dynamics (CFD), based on the finite element method (FEM) were performed to investigate the efficiency of the existing heating, ventilation and air-conditioning (HVAC) plant with a variable air volume (VAV) primary air system. Solid modelling of the room, taking into account thermo-physical properties of building materials, architectural features (e.g., window and wall orientation) and furnishing (e.g., beds, tables and lamps) arrangement of the room, inlet turbulence high induction air diffuser, the return air diffusers and two patients lying on two parallel beds was carried out. Multiphysics modelling was used: a thermo-fluidynamic model (convection-conduction and incompressible Navier-Stokes) was combined with a convection-diffusion model. Three 3D models were elaborated considering different conditions/events of the patients (i.e., the first was considered coughing and/or the second breathing). A particle tracing and diffusion model, connected to cough events, was developed to simulate the dispersal of bacteria-carrying droplets in the isolation room equipped with the existing ventilation system. An analysis of the region of droplet fallout and the dilution time of bacteria diffusion of coughed gas in the isolation room was performed. The analysis of transient simulation results concerning particle path and distance, and then particle tracing combined with their concentration, provided evidence of the formation of zones that should be checked by microclimatic and contaminant control. The present study highlights the fact that the CFD-FEM application is useful for understanding the efficiency, adequacy and reliability of the ventilation system, but also provides important suggestions for controlling air quality, patients' comfort and energy consumption in a hospital. © Tsinghua University Press and Springer-Verlag Berlin Heidelberg 2011.

Entities:  

Keywords:  CFD; HVAC; VAV plant; isolation rooms; transient simulation; ventilation; virus diffusion

Year:  2011        PMID: 32218908      PMCID: PMC7090620          DOI: 10.1007/s12273-011-0019-6

Source DB:  PubMed          Journal:  Build Simul        ISSN: 1996-3599            Impact factor:   3.751


  15 in total

Review 1.  Role of ventilation in airborne transmission of infectious agents in the built environment - a multidisciplinary systematic review.

Authors:  Y Li; G M Leung; J W Tang; X Yang; C Y H Chao; J Z Lin; J W Lu; P V Nielsen; J Niu; H Qian; A C Sleigh; H-J J Su; J Sundell; T W Wong; P L Yuen
Journal:  Indoor Air       Date:  2007-02       Impact factor: 5.770

2.  [Performances of different types of airflow system in operating theatre].

Authors:  D Talon; T Schoenleber; X Bertrand; P Vichard
Journal:  Ann Chir       Date:  2006-03-06

3.  Peptides of human bronchial mucus glycoproteins. Size determination by electron microscopy and by biosynthetic experiments.

Authors:  T Marianne; J M Perini; J J Lafitte; N Houdret; F R Pruvot; G Lamblin; H S Slayter; P Roussel
Journal:  Biochem J       Date:  1987-11-15       Impact factor: 3.857

4.  Development of a method for bacteria and virus recovery from heating, ventilation, and air conditioning (HVAC) filters.

Authors:  James E Farnsworth; Sagar M Goyal; Seung Won Kim; Thomas H Kuehn; Peter C Raynor; M A Ramakrishnan; Senthilvelan Anantharaman; Weihua Tang
Journal:  J Environ Monit       Date:  2006-10

5.  Flow dynamics and characterization of a cough.

Authors:  J K Gupta; C-H Lin; Q Chen
Journal:  Indoor Air       Date:  2009-07-31       Impact factor: 5.770

6.  Operating room ventilation with laminar airflow shows no protective effect on the surgical site infection rate in orthopedic and abdominal surgery.

Authors:  Christian Brandt; Uwe Hott; Dorit Sohr; Franz Daschner; Petra Gastmeier; Henning Rüden
Journal:  Ann Surg       Date:  2008-11       Impact factor: 12.969

7.  Virus diffusion in isolation rooms.

Authors:  P H Kao; R J Yang
Journal:  J Hosp Infect       Date:  2005-12-15       Impact factor: 3.926

Review 8.  Review of aerosol transmission of influenza A virus.

Authors:  Raymond Tellier
Journal:  Emerg Infect Dis       Date:  2006-11       Impact factor: 6.883

9.  Numerical modeling of exhaled droplet nuclei dispersion and mixing in indoor environments.

Authors:  K W Mui; L T Wong; C L Wu; Alvin C K Lai
Journal:  J Hazard Mater       Date:  2009-01-20       Impact factor: 10.588

10.  Hospital and community acquired infection and the built environment--design and testing of infection control rooms.

Authors:  J T Walker; P Hoffman; A M Bennett; M C Vos; M Thomas; N Tomlinson
Journal:  J Hosp Infect       Date:  2007-06       Impact factor: 3.926

View more