Development of a method for bacteria and virus recovery from heating, ventilation, and air conditioning (HVAC) filters.

James E Farnsworth1, Sagar M Goyal, Seung Won Kim, Thomas H Kuehn, Peter C Raynor, M A Ramakrishnan, Senthilvelan Anantharaman, Weihua Tang.   

Abstract

The aim of the work presented here is to study the effectiveness of building air handling units (AHUs) in serving as high volume sampling devices for airborne bacteria and viruses. An HVAC test facility constructed according to ASHRAE Standard 52.2-1999 was used for the controlled loading of HVAC filter media with aerosolized bacteria and virus. Nonpathogenic Bacillus subtilis var. niger was chosen as a surrogate for Bacillus anthracis. Three animal viruses; transmissible gastroenteritis virus (TGEV), avian pneumovirus (APV), and fowlpox virus were chosen as surrogates for three human viruses; SARS coronavirus, respiratory syncytial virus, and smallpox virus; respectively. These bacteria and viruses were nebulized in separate tests and injected into the test duct of the test facility upstream of a MERV 14 filter. SKC Biosamplers upstream and downstream of the test filter served as reference samplers. The collection efficiency of the filter media was calculated to be 96.5 +/- 1.5% for B. subtilis, however no collection efficiency was measured for the viruses as no live virus was ever recovered from the downstream samplers. Filter samples were cut from the test filter and eluted by hand-shaking. An extraction efficiency of 105 +/- 19% was calculated for B. subtilis. The viruses were extracted at much lower efficiencies (0.7-20%). Our results indicate that the airborne concentration of spore-forming bacteria in building AHUs may be determined by analyzing the material collected on HVAC filter media, however culture-based analytical techniques are impractical for virus recovery. Molecular-based identification techniques such as PCR could be used.

Entities:  

Mesh:

Year:  2006        PMID: 17240906     DOI: 10.1039/b606132j

Source DB:  PubMed          Journal:  J Environ Monit        ISSN: 1464-0325


  22 in total

1.  A method to quantify infectious airborne pathogens at concentrations below the threshold of quantification by culture.

Authors:  Timothy D Cutler; Chong Wang; Steven J Hoff; Jeffrey J Zimmerman
Journal:  Can J Vet Res       Date:  2013-04       Impact factor: 1.310

Review 2.  Methods for sampling of airborne viruses.

Authors:  Daniel Verreault; Sylvain Moineau; Caroline Duchaine
Journal:  Microbiol Mol Biol Rev       Date:  2008-09       Impact factor: 11.056

3.  Bioaerosol Sampling: Classical Approaches, Advances, and Perspectives.

Authors:  Gediminas Mainelis
Journal:  Aerosol Sci Technol       Date:  2019-10-04       Impact factor: 4.809

4.  Identifying experimental surrogates for Bacillus anthracis spores: a review.

Authors:  David L Greenberg; Joseph D Busch; Paul Keim; David M Wagner
Journal:  Investig Genet       Date:  2010-09-01

5.  Airborne influenza virus detection with four aerosol samplers using molecular and infectivity assays: considerations for a new infectious virus aerosol sampler.

Authors:  P Fabian; J J McDevitt; E A Houseman; D K Milton
Journal:  Indoor Air       Date:  2009-05-26       Impact factor: 5.770

6.  Evaluation of sampling methods for Bacillus spore-contaminated HVAC filters.

Authors:  M Worth Calfee; Laura J Rose; Jenia Tufts; Stephen Morse; Matt Clayton; Abderrahmane Touati; Nicole Griffin-Gatchalian; Christina Slone; Neal McSweeney
Journal:  J Microbiol Methods       Date:  2013-10-31       Impact factor: 2.363

7.  Wind tunnel-based testing of a photoelectrochemical oxidative filter-based air purification unit in coronavirus and influenza aerosol removal and inactivation.

Authors:  Yuechen Qiao; My Yang; Ian A Marabella; Devin A J McGee; Bernard A Olson; Montserrat Torremorell; Christopher J Hogan
Journal:  Indoor Air       Date:  2021-05-07       Impact factor: 6.554

8.  The Optimization of Methods for the Collection of Aerosolized Murine Norovirus.

Authors:  Corey Boles; Grant Brown; Jae Hong Park; Matthew Nonnenmann
Journal:  Food Environ Virol       Date:  2020-06-10       Impact factor: 4.034

9.  Comparison between Whatman FTA Elute Cards and Conventional Swab for the Detection of Pathogenic Enteric Bacteria Using an RT-qPCR Assay.

Authors:  Na Yue; Zichao Jia
Journal:  Can J Infect Dis Med Microbiol       Date:  2021-07-02       Impact factor: 2.471

10.  Detection and Isolation of Airborne Influenza A H3N2 Virus Using a Sioutas Personal Cascade Impactor Sampler.

Authors:  John A Lednicky; Julia C Loeb
Journal:  Influenza Res Treat       Date:  2013-10-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.