Literature DB >> 32211939

Technological quality requirements for stereotactic radiotherapy : Expert review group consensus from the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy.

Daniela Schmitt1, Oliver Blanck2, Tobias Gauer3, Michael K Fix4, Thomas B Brunner5, Jens Fleckenstein6, Britta Loutfi-Krauss7, Peter Manser4, Rene Werner8, Maria-Lisa Wilhelm9, Wolfgang W Baus10, Christos Moustakis11.   

Abstract

This review details and discusses the technological quality requirements to ensure the desired quality for stereotactic radiotherapy using photon external beam radiotherapy as defined by the DEGRO Working Group Radiosurgery and Stereotactic Radiotherapy and the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy. The covered aspects of this review are 1) imaging for target volume definition, 2) patient positioning and target volume localization, 3) motion management, 4) collimation of the irradiation and beam directions, 5) dose calculation, 6) treatment unit accuracy, and 7) dedicated quality assurance measures. For each part, an expert review for current state-of-the-art techniques and their particular technological quality requirement to reach the necessary accuracy for stereotactic radiotherapy divided into intracranial stereotactic radiosurgery in one single fraction (SRS), intracranial fractionated stereotactic radiotherapy (FSRT), and extracranial stereotactic body radiotherapy (SBRT) is presented. All recommendations and suggestions for all mentioned aspects of stereotactic radiotherapy are formulated and related uncertainties and potential sources of error discussed. Additionally, further research and development needs in terms of insufficient data and unsolved problems for stereotactic radiotherapy are identified, which will serve as a basis for the future assignments of the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy. The review was group peer-reviewed, and consensus was obtained through multiple working group meetings.

Entities:  

Keywords:  FSRT; Radiosurgery; Recommendations; SBRT; SRS; Technique

Year:  2020        PMID: 32211939     DOI: 10.1007/s00066-020-01583-2

Source DB:  PubMed          Journal:  Strahlenther Onkol        ISSN: 0179-7158            Impact factor:   3.621


  19 in total

Review 1.  Stereotactic ablative body radiotherapy for ventricular tachycardia: An alternative therapy for refractory patients.

Authors:  Carolina De La Pinta; Raquel Besse
Journal:  Anatol J Cardiol       Date:  2021-12       Impact factor: 1.596

2.  Evaluation of the ability of the Brainlab Elements Cranial Distortion Correction algorithm to correct clinically relevant MRI distortions for cranial SRT.

Authors:  Paul Retif; Abdourahamane Djibo Sidikou; Christian Mathis; Romain Letellier; Emilie Verrecchia-Ramos; Rémi Dupres; Xavier Michel
Journal:  Strahlenther Onkol       Date:  2022-08-18       Impact factor: 4.033

3.  ADVANCES IN RADIOTHERAPY OF ADRENAL GLAND LESIONS.

Authors:  X E Bacinschi; R M Anghel
Journal:  Acta Endocrinol (Buchar)       Date:  2022 Jan-Mar       Impact factor: 1.104

4.  Quality assurance of a breathing controlled four-dimensional computed tomography algorithm.

Authors:  Juliane Szkitsak; Andre Karius; Christian Hofmann; Rainer Fietkau; Christoph Bert; Stefan Speer
Journal:  Phys Imaging Radiat Oncol       Date:  2022-06-24

5.  Feasibility of Optical Surface-Guidance for Position Verification and Monitoring of Stereotactic Body Radiotherapy in Deep-Inspiration Breath-Hold.

Authors:  Patrick Naumann; Vania Batista; Benjamin Farnia; Jann Fischer; Jakob Liermann; Eric Tonndorf-Martini; Bernhard Rhein; Jürgen Debus
Journal:  Front Oncol       Date:  2020-09-25       Impact factor: 6.244

6.  The influence of small field output factors simulated uncertainties on the calculated dose in VMAT plans for brain metastases: a multicentre study.

Authors:  Stefania Clemente; Maria Daniela Falco; Elisabetta Cagni; Cinzia Talamonti; Mafalda Boccia; Eva Gino; Elena Lorenzini; Federica Rosica; Serenella Russo; Alessandro Alparone; Daniele Zefiro; Christian Fiandra
Journal:  Br J Radiol       Date:  2021-01-22       Impact factor: 3.039

7.  Radiomics for prediction of radiation-induced lung injury and oncologic outcome after robotic stereotactic body radiotherapy of lung cancer: results from two independent institutions.

Authors:  Khaled Bousabarah; Oliver Blanck; Susanne Temming; Maria-Lisa Wilhelm; Mauritius Hoevels; Wolfgang W Baus; Daniel Ruess; Veerle Visser-Vandewalle; Maximilian I Ruge; Harald Treuer; Martin Kocher
Journal:  Radiat Oncol       Date:  2021-04-16       Impact factor: 3.481

8.  Evaluation of the influence of susceptibility-induced magnetic field distortions on the precision of contouring intracranial organs at risk for stereotactic radiosurgery.

Authors:  Veit Mengling; Florian Putz; Frederik Bernd Laun; Rosalind Perrin; Felix Eisenhut; Arnd Dörfler; Rainer Fietkau; Christoph Bert
Journal:  Phys Imaging Radiat Oncol       Date:  2020-08-13

9.  Implementation of a dedicated 1.5 T MR scanner for radiotherapy treatment planning featuring a novel high-channel coil setup for brain imaging in treatment position.

Authors:  Veit Mengling; Christoph Bert; Rosalind Perrin; Siti Masitho; Thomas Weissmann; Sina Mansoorian; Hadi Siavooshhaghighi; Rolf Janka; Sylvain Doussin; Melanie Habatsch; Rainer Fietkau; Florian Putz
Journal:  Strahlenther Onkol       Date:  2020-10-25       Impact factor: 3.621

10.  Patterns of care analysis for salivary gland cancer: a survey within the German Society of Radiation Oncology (DEGRO) and recommendations for daily practice.

Authors:  Jens von der Grün; Claus Rödel; Sabine Semrau; Panagiotis Balermpas; Daniel Martin; Rainer Fietkau; Marlen Haderlein
Journal:  Strahlenther Onkol       Date:  2021-08-24       Impact factor: 3.621

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.