Literature DB >> 32209815

Lesion Detectability and Radiation Dose in Spiral Breast CT With Photon-Counting Detector Technology: A Phantom Study.

Sojin Shim1, Natalia Saltybaeva, Nicole Berger, Magda Marcon, Hatem Alkadhi, Andreas Boss.   

Abstract

OBJECTIVES: The aim of the article was to evaluate the lesion detectability, image quality, and radiation dose of a dedicated clinical spiral breast computed tomography (CT) system equipped with a photon-counting detector, and to propose optimal scan parameter settings to achieve low patient dose levels and optimal image quality.
METHODS: A breast phantom containing inserts mimicking microcalcifications (diameters 196, 290, and 400 μm) and masses (diameters 1.8, 3.18, 4.76, and 6.32 mm) was examined in a spiral breast CT system with systematic variations of x-ray tube currents between 5 and 125 mA, using 2 slabs of 100 and 160 mm. Signal-to-noise ratio and contrast-to-noise ratio measurements were performed by region of interest analysis. Two experienced radiologists assessed the detectability of the inserts. The average absorbed dose was calculated in Monte Carlo simulations.
RESULTS: Microcalcifications in diameters of 290 and 400 μm and masses in diameters of 3.18, 4.76, and 6.32 mm were visible for all tube currents between 5 and 125 mA. Soft tissue masses in a diameter of 1.8 mm were visible at tube currents of 25 mA and higher. Microcalcifications with a diameter of 196 μm were detectable at a tube current of 25 mA and higher in the small, and at a tube current of 40 mA and higher in the large slab. For the small and large breast, at a tube current of 25 and 40 mA, an average dose value of 4.30 ± 0.01 and 5.70 ± 0.02 mGy was calculated, respectively.
CONCLUSIONS: Optimizing tube current of spiral breast CT according to the breast size enables the visualization of microcalcifications as small as 196 μm while keeping dose values in the range of conventional mammography.

Entities:  

Mesh:

Year:  2020        PMID: 32209815     DOI: 10.1097/RLI.0000000000000662

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  9 in total

1.  Breast Cancer Screening: Opportunities and Challenges with Fully 3D Tomographic X-Ray Imaging.

Authors:  Srinivasan Vedantham; Andrew Karellas
Journal:  Bridge (Wash D C)       Date:  2022-03-28

2.  Spiral breast computed tomography (CT): signal-to-noise and dose optimization using 3D-printed phantoms.

Authors:  Manon Germann; Sojin Shim; Florian Angst; Natalia Saltybaeva; Andreas Boss
Journal:  Eur Radiol       Date:  2020-12-02       Impact factor: 5.315

3.  Breast density in dedicated breast computed tomography: Proposal of a classification system and interreader reliability.

Authors:  Jann Wieler; Nicole Berger; Thomas Frauenfelder; Magda Marcon; Andreas Boss
Journal:  Medicine (Baltimore)       Date:  2021-05-07       Impact factor: 1.889

4.  Spiral Computed Tomography in the Quantitative Measurement of the Adjacent Structure of the Left Atrial Appendage in Patients with Atrial Fibrillation.

Authors:  Zhen Zhang; Wei Yan
Journal:  J Healthc Eng       Date:  2021-11-30       Impact factor: 2.682

5.  Radiomics in photon-counting dedicated breast CT: potential of texture analysis for breast density classification.

Authors:  Anna Landsmann; Carlotta Ruppert; Jann Wieler; Patryk Hejduk; Alexander Ciritsis; Karol Borkowski; Moritz C Wurnig; Cristina Rossi; Andreas Boss
Journal:  Eur Radiol Exp       Date:  2022-07-20

6.  INSIDEnet: Interpretable NonexpanSIve Data-Efficient network for denoising in grating interferometry breast CT.

Authors:  Stefano van Gogh; Zhentian Wang; Michał Rawlik; Christian Etmann; Subhadip Mukherjee; Carola-Bibiane Schönlieb; Florian Angst; Andreas Boss; Marco Stampanoni
Journal:  Med Phys       Date:  2022-03-24       Impact factor: 4.506

7.  Iterative phase contrast CT reconstruction with novel tomographic operator and data-driven prior.

Authors:  Stefano van Gogh; Subhadip Mukherjee; Jinqiu Xu; Zhentian Wang; Michał Rawlik; Zsuzsanna Varga; Rima Alaifari; Carola-Bibiane Schönlieb; Marco Stampanoni
Journal:  PLoS One       Date:  2022-09-01       Impact factor: 3.752

8.  Detection of Microcalcifications in Spiral Breast Computed Tomography with Photon-Counting Detector Is Feasible: A Specimen Study.

Authors:  Matthias Wetzl; Evelyn Wenkel; Eva Balbach; Ebba Dethlefsen; Arndt Hartmann; Julius Emons; Christiane Kuhl; Matthias W Beckmann; Michael Uder; Sabine Ohlmeyer
Journal:  Diagnostics (Basel)       Date:  2021-05-09

9.  Applied Machine Learning in Spiral Breast-CT: Can We Train a Deep Convolutional Neural Network for Automatic, Standardized and Observer Independent Classification of Breast Density?

Authors:  Anna Landsmann; Jann Wieler; Patryk Hejduk; Alexander Ciritsis; Karol Borkowski; Cristina Rossi; Andreas Boss
Journal:  Diagnostics (Basel)       Date:  2022-01-13
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.