Suk-Tak Chan1, Karleyton C Evans2, Tian-Yue Song1,2, Juliette Selb1, Andre van der Kouwe1, Bruce R Rosen1, Yong-Ping Zheng3, Andrew Ahn1, Kenneth K Kwong1. 1. Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, Massachusetts, United States of America. 2. Department of Psychiatry, Massachusetts General Hospital, Charlestown, Massachusetts, United States of America. 3. Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong Special Administrative Region, China.
Abstract
BACKGROUND: Hypercapnia during breath holding is believed to be the dominant driver behind the modulation of cerebral blood flow (CBF). However, increasing evidence show that mild hypoxia and mild hypercapnia in breath hold (BH) could work synergistically to enhance CBF response. We hypothesized that breath-by-breath O2-CO2 exchange ratio (bER), defined as the ratio of the change in partial pressure of oxygen (ΔPO2) to that of carbon dioxide (ΔPCO2) between end inspiration and end expiration, would be able to better correlate with the global and regional cerebral hemodynamic responses (CHR) to BH challenge. We aimed to investigate whether bER is a more useful index than end-tidal PCO2 to characterize cerebrovascular reactivity (CVR) under BH challenge. METHODS: We used transcranial Doppler ultrasound (TCD) to evaluate CHR under BH challenge by measuring cerebral blood flow velocity (CBFv) in the middle cerebral arteries. Regional changes in CHR to BH and exogenous CO2 challenges were mapped with blood oxygenation level dependent (BOLD) signal changes using functional magnetic resonance imaging (fMRI). We correlated respiratory gas exchange (RGE) metrics (bER, ΔPO2, ΔPCO2, end-tidal PCO2 and PO2, and time of breaths) with CHR (CBFv and BOLD) to BH challenge. Temporal features and frequency characteristics of RGE metrics and their coherence with CHR were examined. RESULTS: CHR to brief BH epochs and free breathing were coupled with both ΔPO2 and ΔPCO2. We found that bER was superior to either ΔPO2 or ΔPCO2 alone in coupling with the changes of CBFv and BOLD signals under breath hold challenge. The regional CVR results derived by regressing BOLD signal changes on bER under BH challenge resembled those derived by regressing BOLD signal changes on end-tidal PCO2 under exogenous CO2 challenge. CONCLUSION: Our findings provide a novel insight on the potential of using bER to better quantify CVR changes under BH challenge.
BACKGROUND:Hypercapnia during breath holding is believed to be the dominant driver behind the modulation of cerebral blood flow (CBF). However, increasing evidence show that mild hypoxia and mild hypercapnia in breath hold (BH) could work synergistically to enhance CBF response. We hypothesized that breath-by-breathO2-CO2 exchange ratio (bER), defined as the ratio of the change in partial pressure of oxygen (ΔPO2) to that of carbon dioxide (ΔPCO2) between end inspiration and end expiration, would be able to better correlate with the global and regional cerebral hemodynamic responses (CHR) to BH challenge. We aimed to investigate whether bER is a more useful index than end-tidal PCO2 to characterize cerebrovascular reactivity (CVR) under BH challenge. METHODS: We used transcranial Doppler ultrasound (TCD) to evaluate CHR under BH challenge by measuring cerebral blood flow velocity (CBFv) in the middle cerebral arteries. Regional changes in CHR to BH and exogenous CO2 challenges were mapped with blood oxygenation level dependent (BOLD) signal changes using functional magnetic resonance imaging (fMRI). We correlated respiratory gas exchange (RGE) metrics (bER, ΔPO2, ΔPCO2, end-tidal PCO2 and PO2, and time of breaths) with CHR (CBFv and BOLD) to BH challenge. Temporal features and frequency characteristics of RGE metrics and their coherence with CHR were examined. RESULTS:CHR to brief BH epochs and free breathing were coupled with both ΔPO2 and ΔPCO2. We found that bER was superior to either ΔPO2 or ΔPCO2 alone in coupling with the changes of CBFv and BOLD signals under breath hold challenge. The regional CVR results derived by regressing BOLD signal changes on bER under BH challenge resembled those derived by regressing BOLD signal changes on end-tidal PCO2 under exogenous CO2 challenge. CONCLUSION: Our findings provide a novel insight on the potential of using bER to better quantify CVR changes under BH challenge.
Breath hold challenge has been used in the clinical setting as a simple vasoactive stimulus for the assessment of cerebrovascular reactivity (CVR) [1, 2] in patients with carotid artery diseases [3-5] as well as brain tumors [6]. Its use for CVR assessment with transcranial Doppler sonography (TCD) measurement was first demonstrated by Ratnatunga and Adiseshiah [3]. The cerebral blood flow velocities (CBFv) were often measured in the middle cerebral arteries which supply most parts of the brain. The time of breaths (ToB) had often been taken as an indicator of the strength of the vasoactive stimulus to induce changes of cerebral blood flow (CBF). The ratio of CBF to ToB was known as a breath hold index to evaluate CVR [1, 2, 4, 5, 7]. Although TCD offers high temporal resolution to evaluate cerebrovascular responses without the concern of aliasing high frequency hemodynamic signal into the low frequency range, it does not provide regional information. Therefore regional CVR mapping with blood oxygen level-dependent (BOLD) signal changes measured by functional magnetic resonance imaging (fMRI) was used. BOLD-fMRI was used instead of arterial spin labeling (ASL) in MRI perfusion studies due to the low contrast to noise ratio and the low temporal resolution of the ASL technique [8]. ASL image acquisition at a temporal resolution of 4 seconds will under-sample the brain responses within respiratory cycle of 4–6 seconds.Hypercapnia or increased end-tidal partial pressure of CO2 (PETCO2) was commonly measured as a surrogate for the increased arterial CO2 level to evaluate CVR [9-11]. Hypoxia or changes of end-tidal partial pressure of O2 (PETO2) were seldom used to account for CBF changes during breath holding partly due to the common belief that the vasodilatory effect of increased arterial partial pressure of CO2 (PCO2) dominates that of decreased arterial partial pressure of O2 (PO2). Such a belief stemmed from high altitude studies and lab-controlled low oxygen environment reporting that significant CBF changes only happened in hypoxia with arterial PO2 (PaO2) going down to approximately 50 mmHg [12-14]. It should be noted that reports of large CBF increase in response to strong hypoxia were often accompanied by hypocapnia due to hyperventilation in the studies of either high altitudes or lab-controlled low oxygen environment (~8–13% O2) [12-14]. The case is different with breath hold because hypoxia is accompanied by hypercapnia and not by hypocapnia during breath holding.The role of both hypoxia and hypercapnia in breath hold deserves to be examined because arterial PO2 and PCO2 had been reported to work synergistically at normoxia to interact with peripheral chemoreceptors [15-19]. In spontaneous breathing, blood gas levels of O2 and CO2 are optimized by the feedback control of ventilation via chemoreflexes [20] to regulate blood flow and oxygen delivery to the brain as part of a vital homeostatic process [17]. The feedback loops include interaction between central chemoreceptors at the brainstem [21, 22] and peripheral chemoreceptors at the carotid body [23, 24]. While most of the studies on the role of PO2 to stimulate peripheral chemoreceptors at the carotid body had been focused on strong hypoxia [17] where chemoreceptor activities rose quickly in a hyperbolic fashion, Biscoe et al. [15] showed that peripheral chemoreceptor activities could be observed from normoxia to hyperoxia up to arterial PO2 level of 190mmHg and beyond. Lahiri et al. [18] reported that the stimulus thresholds of arterial PO2 and PCO2 for peripheral chemoreceptors were largely interdependent under the normoxic condition where a drop in arterial PO2 was routinely accompanied by increased chemoreceptor activities as well as an enhanced sensitivity of carotid chemoreceptors to arterial PCO2. Several authors [15-19] reported similar findings for normoxic as well as hypoxic conditions. Ventilation, like chemoreceptors, also becomes more sensitive to PCO2 with a slight decrease in PO2 within the range of normoxia (90–110 mmHg). The same interaction between change in PO2 and change in peripheral chemoreceptor activities during spontaneous breathing is also assumed to take place during breath hold.In terms of the relationship between modulated chemoreceptor activities and cerebral hemodynamic responses, previous studies reported that apnea-induced hypoxia and hypercapnia caused chemoreceptor-mediated central vasodilation and concurrent peripheral vasoconstriction to conserve oxygen delivery to the brain [25], leading to an increase in cerebral blood flow (CBF) and a decrease in peripheral oxygen saturation [26]. Enhanced hemodynamic responses to mild hypoxia with maintained eucapnia or in the presence of hypercapnia in humans had also been demonstrated in the work by Shapiro et al. [27] and Mardimae et al. [28]. Those authors reported progressive CBF increase in response to small steps of serial reductions of PO2 starting from normoxia with maintained eucapnia [27] as well as with slight hypercapnia of around 45 mmHg [28]. The findings in these studies suggested that mild hypercapnia could increase the sensitivity of the CBF response to a very mild level of hypoxia and the ranges of mild PO2 and PCO2 changes reported are achievable by breath hold.Beyond the belief of CO2 being the dominant effect to account for CBF changes, the perception that effect of O2 on CBF simply reflects the effect of CO2 is often associated with another belief that changes of PO2 and PCO2 in respiration are mirror image of each other [29]. However, respiratory data acquired on 12 subjects in the study by Lenfant [30] showed that the time courses of O2 and CO2 were interdependent but not redundant in terms of their temporal and frequency characteristics. Even without being redundant, such interdependence can still pose some problems for CVR analysis. There is a question of collinearity when interdependent changes of PCO2 and PO2 are included as predictor variables in the same regression model of CVR quantification. We are seeking a combination of PO2 and PCO2 that can properly characterize the interdependence between PO2 and PCO2 without creating a problem of collinearity in CVR analysis. The use of the breath-by breathO2-CO2 exchange ratio described in the alveolar air equation [31, 32] is a natural target to be investigated for breath hold challenge in the regression model.We preferred the terms ΔPO2 (inspired PO2 –expired PO2) and ΔPCO2 (expired PCO2 –inspired PCO2) over the more commonly used PETO2 and PETCO2 because the breath-by-breath ΔPO2 and ΔPCO2 are the terms used in the alveolar air equation [31, 32] to describe the change of gas partial pressure in systemic O2 uptake and that in CO2 release respectively. We also prefer to use ΔPO2/ΔPCO2 as our breath-by-breathO2-CO2 exchange ratio (bER). bER takes advantage of its ratio format to reduce the unwanted effects of ventilatory volume fluctuations due to isolated deep breaths common to ΔPO2 and ΔPCO2 measured. bER is mathematically equivalent to the reciprocal of the respiratory exchange ratio (RER) from alveolar air equation [31, 32], except that bER is a dynamic breath-by-breath measurement and RER is a steady-state time-averaged measurement over a period of time. RER has been used to evaluate resting systemic metabolic rate [33-35]. Some technical differences do need to be mentioned between RER used in the literature and bER we used in this study. Traditionally, RER is derived by measuring the respiratory flow and the expired gases collected in Douglas bag connected to a closed circuit over several minutes. bER is derived here by measuring the inspired and expired gases with a nasal tubing at each breath.In this study, we hypothesized that mild hypoxia and hypercapnia work synergistically to increase CBF under breath hold challenge. The primary objective was to evaluate our hypothesis that bER would be a more useful index than PETCO2 to correlate with the changes of CBFv and BOLD signals in the evaluation of cerebral hemodynamic responses to the breath hold challenge. To address the question of redundancy among respiratory gas exchange (RGE) metrics, we examined the correlations among bER, ΔPCO2, ΔPO2, PETCO2, PETO2 and ToB in both TCD and MRI sessions. In the first part of the study, we correlated the time series of the RGE metrics (bER, ΔPCO2, ΔPO2 and ToB) with those of CBFv and BOLD signal changes under the protocol of breath hold challenge. We then examined the temporal features and frequency characteristics of these RGE metrics as well as their coherence with CBFv and BOLD signal changes. In the second part of the study, we compared the regional CVR maps obtained by regressing BOLD signal changes on selected RGE metrics including bER, PETCO2 and ToB under breath hold challenge with regional CVR maps obtained by regressing BOLD signals changes on PETCO2 obtained under exogenous CO2 hypercapnic challenge. The success of such association between bER and cerebral hemodynamic responses, in addition to offering a better physiological model to characterize cerebral hemodynamic responses under breath hold challenge, would also provide a novel insight in the study of brain-body interaction.
Materials and methods
Participants
Seventeen volunteers aged from 22 to 48 years (mean = 31.18 years; SD = 8.78 years; 11M and 6F) were included. All of them were recruited by e-mail and poster placement within the Partners hospital network. They were screened to exclude neurological, mental and medical disorders and drug abuse. TCD and MRI scanning were performed in the Athinoula A. Martinos Center for Biomedical Imaging at the Massachusetts General Hospital of Partners HealthCare. All the experimental procedures were explained to the subjects, and signed informed consent was obtained prior to participation in the study. All components of this study were performed in compliance with the Declaration of Helsinki and all procedures were approved by Partners Human Research Committee.Our study was divided into Part 1 and Part 2. In Part 1, we aimed to correlate the RGE metrics including bER, ΔPO2, ΔPCO2 and ToB with cerebral hemodynamic responses including CBFv and BOLD signal changes to breath hold challenge. We also examined the temporal features and frequency characteristics of RGE metrics and their coherence with cerebral hemodynamic responses. Sixteen out of 17 subjects performed breath hold tasks in the MRI sessions, while 12 of them participated in TCD sessions. In Part 2, we aimed to assess the usefulness of bER in the regional breath hold CVR quantification by comparing the regional CVR maps obtained by regressing BOLD signal changes on bER, PETCO2 and ToB under breath hold challenge with regional CVR maps obtained by regressing BOLD signals changes on PETCO2 under exogenous CO2 challenge. Ten out of 17 subjects had additional exogenous CO2 challenge for comparison. Before we correlated the changes of RGE metrics with CBFv and BOLD signal changes under breath hold challenge, we examined the correlations among the RGE metrics (bER, ΔPCO2, ΔPO2, PETCO2, PETO2 and ToB) acquired in both TCD and MRI sessions.
Part 1: Breath hold challenge
Transcranial Doppler scanning
Before the study of blood flow velocity in intracranial arteries, subject was allowed to rest at least 20–30 minutes for hemodynamic stabilization. The blood pressure measured in the subject was within the normal range [36]. With the subject in a sitting position, a dual probe setting with 2MHz transducers in conjunction with TCD system (Delicate EMS-9U, Shenzhen, China) was used for simultaneous recording of CBFv in the middle cerebral arteries (MCA) on both left and right sides while the subject was performing the breath hold task. Two transducers were attached onto the left and right temporal bone window by velcro. The depth of the Doppler samples was confined to the M1 segment, which is at the main stem of the MCA, for all the subjects.The timing of the breath hold task was presented visually to the subject by a computer using the software Eprime Professional 2.0 (Psychology Software Tools, Inc., Pittsburgh, USA). A rehearsal session was given to each subject to practice breath hold task. Each subject was instructed via visual cues to perform 6 epochs of 30-second breath hold interleaved with 60–90 seconds of free breathing (Fig 1). They were instructed by visual cues to only hold their breath for as long as they could during the 30-second period. Multiple epochs of breath holding followed by free breathing increased the samples for quantitative analysis. The total duration of the breath hold protocol lasted 10 minutes.
Fig 1
Paradigms of (A) breath hold and (B) exogenous CO2 challenges. The timing for the onset and the end of breath hold epochs is the same as that for exogenous CO2 hypercapnic epochs. The duration of normal breathing phases in breath hold challenge and normocapnic phases in exogenous CO2 challenge varies from 60 seconds to 90 seconds.
Paradigms of (A) breath hold and (B) exogenous CO2 challenges. The timing for the onset and the end of breath hold epochs is the same as that for exogenous CO2 hypercapnic epochs. The duration of normal breathing phases in breath hold challenge and normocapnic phases in exogenous CO2 challenge varies from 60 seconds to 90 seconds.Physiological changes including PCO2, PO2, electrocardiogram (ECG) and peripheral blood pressure were measured simultaneously with TCD acquisition. A small nasal tubing was placed at the subject’s nostril to sample PCO2 and PO2 via gas analyzers (Capstar-100, Oxystar-100, CWE, Inc., PA, USA) after calibrating to the barometric pressure of the day of TCD scanning and correcting for vapor pressure. Peripheral blood pressure was continuously measured with Finometer MIDI (Finapres Medical Systems B.V., Netherlands). All the TCD and physiological measurements were synchronized using trigger signals from E-prime. CBFv time series and physiological recordings were stored for offline data analysis.
MRI acquisition
MRI brain scanning was performed on a 3-Tesla scanner (Siemens Medical, Erlangen, Germany). The head was immobilized in a standard head coil with foam pads. The following whole brain MRI datasets were acquired on each subject: 1) standard high-resolution sagittal images acquired with volumetric T1-weighted 3D-MEMPRAGE sequence (TR = 2530ms, TE = 1.74ms/3.6ms/5.46ms/7.32ms, flip angle = 7°, FOV = 256×256mm, matrix = 256×256, slice thickness = 1mm); 2) BOLD-fMRI images acquired with gradient-echo echo planar imaging (EPI) sequence (TR = 1450ms, TE = 30ms, flip angle = 90°, FOV = 220×220mm, matrix = 64×64, slice thickness = 5mm, slice gap = 1mm) while the subject was performing the breath hold task. The breath hold task and the physiological set-up used for gas sampling in MRI session were the same as those used in TCD sessions. The gas analyzers were again calibrated to the barometric pressure of the day of MRI scanning and corrected for vapor pressure. ECG was measured using Siemens physiological monitoring unit. Physiological changes including PCO2, PO2 and ECG were measured simultaneously with MRI acquisition. All the physiological measurements were synchronized using trigger signals from the MRI scanner. BOLD-fMRI images and physiological recordings were stored for offline data analysis.
Part 2: Exogenous CO2 challenge
Ten out of 16 subjects had additional exogenous CO2 challenge in the MRI session. Given that there is significant inter-individual variance in resting PETCO2 [37], resting PETCO2 was assessed in those subject via calibrated capnograph before the exogenous CO2 challenge. Subject wore nose-clip and breathed through a mouth-piece on an MRI-compatible circuit designed to maintain the PETCO2 within ± 1–2 mmHg of target PETCO2 [38, 39]. The fraction of inspired carbon dioxide was adjusted to produce steady-state conditions of normocapnia and mild hypercapnia (4–8 mmHg above the subject’s resting PETCO2). The CO2 challenge paradigm consisted of 2 consecutive phases (normocapnia and mild hypercapnia) repeating 6 times with 3 epochs of 4 mmHg increase and 3 epochs of 8 mmHg increase of PETCO2 (Fig 1). The normocapnia phase lasted 60–90 seconds, while the mild hypercapnia phase lasted 30 seconds. The total duration of the exogenous CO2 hypercapnic challenge lasted 10 minutes.When the subject had exogenous CO2 challenge in MRI session, BOLD-fMRI images were acquired using the same EPI sequence for breath hold challenge. The PCO2 and PO2 were sampled through the air filter connected with the mouthpiece and the sampled gases were measured by calibrated gas analyzers. The respiratory flow was measured with respiratory flow head (MTL300L, AdInstruments, Inc., CO, USA) on the breathing circuit via calibrated spirometer (FE141, AdInstruments, Inc., CO, USA). The physiological measurements were synchronized with MRI images using trigger signals from MRI scanner. All the BOLD-fMRI images and physiological recordings were stored for offline data analysis.
Data analysis
Processing of physiological data
The physiological data from both TCD and MRI sessions were analyzed using Matlab R2014a (Mathworks, Inc., Natick, MA, USA). Technical delay of PCO2 and PO2 was corrected by cross-correlating the time series of PCO2 and PO2 with respiratory phases determined from the artifactual displacement due to chest excursion on ECG time series for the breath hold runs in the TCD sessions, with the respiratory phases from the respiratory bellow for the breath hold runs in the MRI sessions, and with the respiratory flow for the exogenous CO2 runs.End inspiration (I) and end expiration (E) were defined on the time series of PO2 and PCO2 (S1 Fig). They were verified by the inspiratory and expiratory phases on the respiration time series. The breath-by-breath end-tidalCO2 (PETCO2) and end-tidal O2 (PETO2) were extracted at the end expiration of PCO2 and PO2 time series respectively. Changes of the gas parameters during breath hold periods were interpolated by the values measured immediately before and after the breath hold periods. The duration of breathing cycle, which is known as time of breath (ToB), was derived by subtracting the timing in seconds of the 2 consecutive end expiration markers. Breath-by-breathO2-CO2 exchange ratio (bER) is defined as the ratio of the change in PO2 (ΔPO2 = inspired PO2 –expired PO2) to the change in PCO2 (ΔPCO2 = expired PCO2 –inspired PCO2) measured between end inspiration and end expiration in each respiratory cycle.Simple correlation analyses were applied on the time series of RGE metrics (bER, ΔPCO2, ΔPO2, PETCO2, PETO2 and ToB) in pairs, which were acquired in both TCD and MRI sessions. Time series of the RGE metrics including bER, ΔPO2, ΔPCO2 and ToB were also used in the CBFv and BOLD data analyses.
Preprocessing of CBFv data
The CBFv data were analyzed using Matlab R2014a (Mathworks, Inc., Natick, MA, USA). A median filter was applied to the data to reduce artifactual spikes. Beat-by-beat systolic peaks and end-diastolic troughs were determined using custom Matlab function and corrected on the graphical user interface incorporated in the function. Systolic peaks and end-diastolic troughs of cardiac cycles on the CBFv time series showing persistent artifacts were excluded in the following analysis. TCD data in both left and right MCAs were acquired on 12 subjects. One of the 12 TCD datasets had persistent artifacts in over one-third of the time series acquired in the LMCA. The CBFv time series in the LMCA of that particular TCD dataset was excluded in further analysis. Time series of mean CBFv was derived by averaging the CBFv over each cardiac cycle. In order to reduce the large inter-individual variations of absolute blood flow velocities [40, 41] and to remove the dependence of insonation angle [42], the percent change of CBFv (ΔCBFv) of the left and right MCAs relative to baseline value was derived. The mean CBFv for a period of 30 seconds at the beginning of the time series was chosen as the baseline because the subject was in resting state and the CBFv acquired within this period had the least effect from the respiratory challenges.
Preprocessing of BOLD-fMRI data
All the BOLD-fMRI data were imported into the software Analysis of Functional NeuroImage (AFNI) [43] (National Institute of Mental Health, http://afni.nimh.nih.gov) for time-shift correction, motion correction, normalization and detrending. The first 12 volumes in the first 12 time points of each functional dataset, collected before equilibrium magnetization was reached, were discarded. Each functional dataset was corrected for slice timing, motion-corrected and co-registered to the first image of the first functional dataset using three-dimensional volume registration. It was then normalized to its mean intensity value across the time-series. Voxels located within the ventricles and outside the brain defined in the parcellated brain volume using FreeSurfer [44] (MGH/MIT/HMS Athinoula A. Martinos Center for Biomedial Imaging, Boston, http://surfer.nmr.mgh.harvard.edu) were excluded from the following analyses of functional images. The time-series of each voxel in the normalized functional dataset was detrended with the 5th order of polynomials to remove the low drift frequency. Individual brain volumes with time series of percent BOLD signal changes (ΔBOLD) were derived.
Part 1
Correlation analysis between cerebral hemodynamic responses and RGE metrics
The cerebral hemodynamic responses (ΔCBFv and ΔBOLD) were separately correlated with the RGE metrics including bER, ΔPCO2, ΔPO2 and ToB. The correlation indicated by Pearson's correlation coefficient was considered significant at p<0.05. Fisher Z-transformation was used to transform Pearson’s correlation coefficients to Fisher Z scores for group analysis. Paired t-tests were used to compare the Fisher Z scores representing the correlation between cerebral hemodynamic responses and bER with those indicating the correlation between cerebral hemodynamic responses and RGE metrics other than bER. Differences were considered to be significant at p<0.05.
Dynamic analysis of coherence between cerebral hemodynamic responses and RGE metrics as function of time and frequency
Wavelet transform coherence is a method for analyzing the coherence and phase lag between two time series as a function of both time and frequency [45-47]. It is therefore well suited to investigating non-stationary changes in coupling between the time series of cerebral hemodynamic responses (ΔCBFv and ΔBOLD) and the time series of RGE metrics including bER, ΔPCO2, ΔPO2 and ToB, as well as the phase lag of the cerebral hemodynamic responses to each of the metrics. The time series of ΔBOLD were extracted from left gray matter (LGM), right gray matter (RGM), left white matter (LWM) and right white matter (RWM). We used the Matlab wavelet cross-spectrum toolbox developed by Grinsted et al. [46]. Squared wavelet coherence between time series of RGE metrics and cerebral hemodynamic responses (ΔCBFv and ΔBOLD) was separately plotted with x-axis as time and y-axis as scale which had been converted to its equivalent Fourier period. An example of squared wavelet coherence between bER and ΔCBFv in right MCA from a representative subject under breath hold challenge is shown in S2 Fig. The magnitude of wavelet transform coherence ranged between 0 and 1 that can be conceptualized as a localized correlation coefficient in time and frequency space [46]. The phase angle between the two time series at particular samples of the time-frequency plane is indicated by an arrow: a rightward pointing arrow indicates that the time series are in phase, or positively correlation (ϕ = 0); a leftward pointing arrow indicates anticorrelation (ϕ = π), and the downward and upward pointing arrows indicate phase angles of π/2 and -π/2 relative to ϕ = 0, respectively. Areas inside the ‘cone of influence’, which are locations in the time-frequency plane where edge effects give rise to lower confidence in the computed values, are shown in faded color outside of the conical contour. The statistical significance level of the wavelet coherence is estimated using Monte Carlo method and the 5% significance level against red noise is shown as thick contour in the squared wavelet coherence plot. The wavelet coherence magnitudes and phases bounded by thick contour outside the cone of influence are considered significant.Time-averaged coherence is defined as the total significant coherence at each scale of Fourier periods (converted into frequency) where the wavelet coherence magnitude exceeds 95% significance level, normalized by the maximum possible coherence outside the cone of influence at that particular scale (S2 Fig). It is interpreted in the similar way as the coherence in the transfer function analysis which has been used in cerebral autoregulation study [48]. The mean time-averaged coherence at the phase lags of 0±π/2 and π±π/2 were plotted for all subjects included in TCD or MRI sessions to explore the Fourier periods/frequency bandwidths that oscillations of cerebral hemodynamic responses (ΔCBFv and ΔBOLD) were in synchrony with each physiological time series of bER, ΔPO2, ΔPCO2 and ToB when the subjects were performing breath hold task.
Part 2
Linear regression for CVR quantification
Linear regression analysis was used to derive CVR from the time series of ΔBOLD and vasoactive stimulus when the subject was under breath hold and exogenous CO2 challenges. The time series of each of the commonly used vasoactive stimuli (bER, PETCO2 and ToB) served as a regressor in a separate linear regression analysis. CVR was defined as the percent BOLD signal changes per unit change of the vasoactive stimulus. Therefore CVR was quantified by the coefficient of regression, i.e. the slope.The statistical parametric maps for individual subjects were cluster-corrected using a threshold estimated with Monte Carlo simulation algorithm. Individual subject brain volume with CVR magnitude was registered onto each subject’s anatomical scan and transformed to the standardized space of Talairach and Tournoux [49]. In order to protect against type I error, individual voxel probability threshold of p<0.005 was held to correct the overall significance level to α<0.05. Monte Carlo simulation was used to correct for multiple comparisons [50]. Based upon a Monte Carlo simulation with 2000 iteration processed with ClustSim program [51], it was estimated that a 476mm3 contiguous volume would provide the significance level α<0.05, which met the overall corrected threshold of p<0.05.
Group comparison of CVR between breath hold and exogenous CO2 challenges
For each subject who participated in both breath hold and exogenous CO2 MRI scanning, CVR values were derived from regressing ΔBOLD on bER (CVRBH-bER), ΔBOLD on PETCO2 (CVRBH-PETCO2) and ΔBOLD on ToB (CVRBH-ToB) when the subjects were under breath hold challenge. CVRBH-bER, CVRBH-PETCO2 and CVRBH-ToB values were separately averaged in each of the 160 brain regions parcellated by the software FreeSurfer. Using the same method, CVR values during exogenous CO2 challenge were obtained by regressing ΔBOLD on PETCO2 (CVRCO2-PETCO2). CVRCO2-PETCO2 values were averaged in each of the 160 brain regions. To study the CVR changes in group, one-sample t-tests were applied onto the brain volumes with regional CVRBH-bER, CVRBH-PETCO2, CVRBH-ToB and CVRCO2-PETCO2. Differences were considered significant at false discovery rate adjusted pfdr<0.05.The physiological mechanisms underlying breath holding and exogenous CO2hypercapnia are potentially different. To study the precision of vasoactive stimulus in predicting the regional cerebral hemodynamic responses, percentage of voxels in each region having significant CVR changes that survived at cluster-corrected p<0.05 in individual subject analysis, in short vCVR, were calculated. Individual subject brain volumes with regional vCVR due to PETCO2, (vCVRBH-PETCO2), ToB (vCVRBH-ToB) and bER (vCVRBH-bER) were obtained in breath hold MRI scanning, while those with regional vCVR due to PETCO2 (vCVRCO2-PETCO2) were obtained in exogenous CO2 MRI scanning. One sample t-tests were again applied for group analysis. Differences were considered significant at pfdr<0.05.To study the usefulness of PETCO2, ToB and bER in CVR quantification under breath hold challenge, using vCVRCO2-PETCO2 as reference, paired t-tests were applied to compare the regional brain maps of vCVRCO2-PETCO2 under exogenous CO2 challenge with those of vCVRBH-PETCO2, vCVRBH-ToB and vCVRBH-bER in groups. Differences were considered significant at pfdr<0.05.
Results
Subject demographics were shown in Table 1. The PETCO2, PETO2, ΔPCO2, ΔPO2 and bER measured in the baseline periods, i.e. the period before the first breath hold epoch, in the TCD and MRI sessions were summarized in Tables 2 and 3 respectively. The breath hold duration, the changes of ΔPCO2, ΔPO2, bER, ΔCBFv and ΔBOLD averaged over the 6 breath hold epochs from the onset to the end of each breath hold epoch were also included. Most of the subjects were able to hold their breaths for 30 seconds on average. The averaged changes of ΔPO2 from the onset to the end of the breath hold epochs were almost 3 to 4 folds larger than those of ΔPCO2.
Table 1
Subject demographics and their participation in breath hold and exogenous CO2 challenges in the TCD and MRI sessions.
TCD
MRI
Subjects
Gender
Age
Breath Hold Challenge
Breath Hold Challenge
Exogenous CO2 Challenge
s1
M
35
-
√
√
s2
M
48
-
√
√
s3
M
22
-
√
√
s4
M
38
√
√
√
s5
M
28
√
√
-
s6
M
27
√
√
√
s7
M
32
√
√
√
s8
M
22
√
√
√
s9
M
32
√
√
√
s10
F
26
√
√
√
s11
F
27
√
√
√
s12
F
47
√
√
-
s13
M
46
-
√
-
s14
F
25
√
√
-
s15
F
23
√
√
-
s16
M
29
-
√
-
s17
F
23
√
-
-
Number of subjects:
12
16
10
Table 2
RGE metrics and ΔCBFv in TCD sessions.
Baseline
Averaged Changes From the Onset to the End of Breath Hold Epochs
Subjects
PETCO2 (mmHg)
PETO2 (mmHg)
ΔPCO2 (mmHg)
ΔPO2 (mmHg)
bER
Breath Hold Duration (seconds)
ΔPCO2 (mmHg)
ΔPO2 (mmHg)
bER
ΔCBFv in LMCA (%)
ΔCBFv in RMCA (%)
s4
39.6 (0.5)
108.5 (0.6)
39.7 (0.5)
42.7 (0.6)
1.1 (0.0)
30.7 (1.3)
8.9 (7.7)
25.1 (14.2)
0.4 (0.1)
43.4 (9.2)
43.4 (9.1)
s5
39.5 (1.7)
112.0 (2.5)
37.3 (4.4)
44.6 (5.4)
1.2 (0.0)
35.5 (0.6)
3.4 (0.8)
18.2 (2.4)
0.4 (0.1)
21.1 (4.6)
31.8 (2.7)
s6
34.3 (0.5)
116.5 (0.7)
33.6 (0.5)
32.2 (0.7)
1.0 (0.0)
33.1 (1.4)
7.7 (4.1)
32.2 (9.5)
0.6 (0.1)
37.2 (6.5)
40.5 (10.3)
s7
39.2 (1.0)
102.9 (1.5)
39.3 (1.0)
48.7 (1.7)
1.2 (0.0)
31.7 (2.4)
8.3 (1.5)
38.6 (5.7)
0.7 (0.1)
51.3 (12.6)
46.7 (11.2)
s8
38.3 (0.7)
104.6 (1.2)
37.3 (0.6)
46.4 (1.4)
1.2 (0.0)
33.0 (1.4)
5.6 (3.7)
27.4 (11.4)
0.5 (0.1)
42.5 (7.9)
41.9 (7.4)
s9
34.7 (0.4)
106.4 (0.9)
35.1 (0.4)
45.9 (1.0)
1.3 (0.0)
38.2 (4.4)
2.8 (3.6)
11.4 (17.8)
0.2 (0.3)
28.7 (12.9)
28.6 (8.8)
s10
30.7 (0.8)
116.2 (2.2)
30.6 (0.4)
36.8 (1.8)
1.2 (0.0)
34.1 (1.4)
8.5 (1.0)
39.3 (6.0)
0.8 (0.2)
31.1 (9.0)
32.6 (7.6)
s11
35.6 (0.4)
109.9 (0.7)
35.0 (0.4)
40.3 (0.8)
1.2 (0.0)
32.6 (1.5)
4.7 (1.5)
27.7 (3.1)
0.6 (0.1)
—
39.5 (7.4)
s12
35.3 (0.2)
116.0 (0.5)
34.6 (0.2)
35.0 (0.8)
1.0 (0.0)
32.1 (1.5)
8.7 (1.3)
40.3 (3.0)
0.8 (0.0)
43.6 (2.3)
52.5 (1.7)
s14
33.9 (0.3)
121.2 (0.7)
30.1 (0.5)
32.0 (1.1)
1.1 (0.0)
31.7 (3.8)
3.9 (1.6)
17.5 (2.3)
0.5 (0.1)
51.1 (3.2)
46.1 (5.8)
s15
31.9 (0.8)
118.8 (0.7)
28.3 (1.3)
32.8 (1.2)
1.2 (0.0)
30.6 (2.3)
8.0 (3.9)
27.5 (3.5)
0.7 (0.2)
53.0 (7.0)
50.8 (7.0)
s17
31.9 (2.1)
120.2 (2.8)
27.5 (3.5)
31.3 (4.5)
1.1 (0.0)
23.3 (2.7)
2.5 (3.7)
15.8 (9.8)
0.5 (0.3)
38.9 (9.1)
36.1 (5.7)
Baseline mean values (SD) of PETCO2, PETO2, ΔPCO2, ΔPO2 and bER for all subjects (n = 12) who were under breath hold challenge in the TCD sessions (left). The averaged changes (SD) of breath hold duration, ΔPCO2, ΔPO2, bER, ΔCBFv measured in LMCA and RMCA from the onset to the end of the breath hold epochs in the TCD sessions (right).
Table 3
RGE metrics and ΔBOLD in MRI sessions.
Baseline
Averaged Changes From the Onset to the End of Breath Hold Epochs
Subjects
PETCO2 (mmHg)
PETO2 (mmHg)
ΔPCO2 (mmHg)
ΔPO2 (mmHg)
bER
Breath Hold Duration(seconds)
ΔPCO2 (mmHg)
ΔPO2 (mmHg)
bER
ΔBOLD in LGM (%)
ΔBOLD in RGM (%)
ΔBOLD in LWM (%)
ΔBOLD in RWM (%)
s1
42.9 (0.7)
99.3 (2.3)
42.5 (0.7)
54.0 (2.8)
1.3 (0.0)
33.4 (3.1)
3.9 (2.4)
29.7 (7.6)
0.6 (0.1)
2.3 (0.6)
2.2 (0.4)
1.0 (0.2)
1.0 (0.2)
s2
38.7 (0.1)
113.8 (0.2)
36.6 (0.6)
32.7 (0.4)
0.9 (0.0)
31.7 (1.4)
9.5 (2.7)
40.5 (2.5)
0.8 (0.1)
2.1 (0.7)
2.2 (0.5)
1.1 (0.2)
1.2 (0.2)
s3
36.1 (0.3)
112.7 (1.1)
35.9 (0.3)
38.1 (1.7)
1.1 (0.0)
32.6 (2.7)
5.3 (1.9)
46.8 (5.3)
1.0 (0.2)
2.3 (1.3)
2.5 (1.6)
1.3 (0.6)
1.3 (0.8)
s4
39.4 (0.7)
104.1 (1.2)
39.2 (0.7)
44.2 (1.5)
1.1 (0.0)
35.5 (1.4)
1.7 (1.3)
17.3 (6.8)
0.4 (0.1)
2.5 (0.4)
3.7 (1.1)
1.3 (0.2)
1.6 (0.6)
s5
32.4 (0.4)
117.1 (0.4)
32.1 (0.4)
32.4 (0.5)
1.0 (0.0)
35.3 (1.3)
7.6 (5.4)
30.9 (6.0)
0.7 (0.1)
1.6 (0.6)
1.5 (0.3)
0.7 (0.2)
0.9 (0.4)
s6
39.0 (0.6)
109.8 (0.6)
37.5 (0.8)
38.3 (0.9)
1.0 (0.0)
32.2 (2.1)
9.4 (3.9)
39.9 (7.7)
0.8 (0.1)
4.0 (1.2)
3.5 (1.2)
2.1 (0.4)
1.6 (0.6)
s7
40.3 (0.6)
109.0 (2.4)
38.6 (0.5)
41.3 (2.8)
1.1 (0.1)
32.9 (1.5)
3.5 (3.5)
34.3 (6.4)
0.7 (0.1)
1.9 (0.1)
2.2 (0.5)
1.2 (0.7)
0.9 (0.2)
s8
37.7 (0.2)
103.1 (0.3)
37.1 (0.2)
47.9 (0.4)
1.3 (0.0)
35.4 (1.1)
3.0 (3.7)
22.4 (14.9)
0.6 (0.0)
2.7 (0.6)
2.9 (0.8)
1.3 (0.4)
1.2 (0.3)
s9
41.3 (0.4)
106.6 (1.4)
40.0 (0.4)
44.6 (1.7)
1.1 (0.0)
33.9 (4.7)
6.8 (4.0)
35.9 (21.3)
0.7 (0.4)
1.9 (0.6)
2.1 (0.7)
1.0 (0.4)
0.9 (0.2)
s10
36.6 (0.2)
117.6 (0.9)
34.3 (0.2)
35.9 (0.9)
1.0 (0.0)
31.5 (1.2)
8.3 (0.9)
50.9 (4.1)
1.0 (0.1)
4.3 (1.6)
2.5 (0.4)
2.0 (0.8)
1.2 (0.2)
s11
34.2 (0.2)
114.7 (0.7)
33.1 (0.2)
35.7 (0.9)
1.1 (0.0)
36.4 (1.7)
0.0 (0.6)
4.5 (5.5)
0.2 (0.1)
2.0 (0.4)
1.6 (0.1)
1.2 (0.4)
0.9 (0.4)
s12
37.6 (0.4)
113.6 (1.5)
36.0 (0.4)
40.0 (1.7)
1.1 (0.0)
32.0 (1.1)
1.6 (1.6)
26.0 (4.9)
0.8 (0.1)
2.6 (0.4)
2.7 (0.6)
1.6 (0.4)
1.3 (0.4)
s13
36.3 (0.6)
109.1 (3.7)
34.1 (0.5)
44.4 (4.5)
1.3 (0.1)
31.8 (4.1)
3.7 (6.3)
15.8 (16.0)
0.4 (0.2)
1.9 (0.2)
2.0 (0.3)
1.0 (0.1)
1.0 (0.1)
s14
36.1 (0.9)
114.6 (0.9)
31.7 (0.6)
38.1 (0.8)
1.2 (0.0)
35.7 (0.8)
3.6 (1.6)
17.2 (4.4)
0.4 (0.1)
2.0 (0.9)
1.5 (0.3)
0.9 (0.1)
0.8 (0.2)
s15
35.8 (0.5)
115.9 (0.9)
32.8 (0.9)
37.7 (1.3)
1.2 (0.0)
34.1 (0.9)
7.9 (5.3)
30.7 (8.4)
0.6 (0.1)
1.4 (0.2)
4.3 (4.1)
0.9 (0.1)
1.6 (0.9)
s16
34.8 (0.5)
119.9 (1.0)
31.4 (0.5)
23.9 (1.2)
0.8 (0.0)
27.7 (6.5)
1.6 (2.1)
11.8 (4.0)
0.3 (0.1)
1.3 (0.6)
1.3 (0.4)
0.7 (0.4)
0.6 (0.2)
Baseline mean values (SD) of PETCO2, PETO2, ΔPCO2, ΔPO2 and bER for all subjects (n = 16) who were under breath hold challenge in the MRI sessions (left). The averaged changes (SD) of breath hold duration, ΔPCO2, ΔPO2, bER, ΔBOLD measured in LGM, RGM, LWM and RWM from the onset to the end of the breath hold epochs in the MRI sessions (right).
Baseline mean values (SD) of PETCO2, PETO2, ΔPCO2, ΔPO2 and bER for all subjects (n = 12) who were under breath hold challenge in the TCD sessions (left). The averaged changes (SD) of breath hold duration, ΔPCO2, ΔPO2, bER, ΔCBFv measured in LMCA and RMCA from the onset to the end of the breath hold epochs in the TCD sessions (right).Baseline mean values (SD) of PETCO2, PETO2, ΔPCO2, ΔPO2 and bER for all subjects (n = 16) who were under breath hold challenge in the MRI sessions (left). The averaged changes (SD) of breath hold duration, ΔPCO2, ΔPO2, bER, ΔBOLD measured in LGM, RGM, LWM and RWM from the onset to the end of the breath hold epochs in the MRI sessions (right).
Correlation among RGE metrics
The correlations among the RGE metrics (bER, ΔPCO2, ΔPO2, PETCO2, PETO2, and ToB) in TCD and MRI sessions are shown in S1 Fig. Strong and positive correlation was found between bER and ΔPO2 consistently in all subjects (Pearson's r, 0.70–0.98, p<0.001), while the correlation between bER and ΔPCO2 varied from weak to moderate (Pearson's r, 0.07–0.75) (S1 Table). Moderate to strong correlation was observed between ΔPO2 and ΔPCO2 (Pearson's r, 0.44–0.88), and between PETO2 and PETCO2 (Pearson's r, 0.46–0.91). Such correlations suggest that ΔPO2 and ΔPCO2 (or PETO2 and PETCO2) are not necessarily redundant. Similar observation of non-redundancy between PETO2 and PETCO2 (correlation coefficients, 0.25–0.93) during spontaneous breathing was also reported by Lenfant et al. [30]. The different ranges of correlation strength observed between ΔPO2 and ΔPCO2 in the TCD and MRI sessions may be due to the interaction of the subjects with the environment. Subjects were sitting in an open and quiet environment in the TCD sessions while they were in supine position in a noisy MRI scanner bore. Many previous studies reported that a change from supine posture to sitting upright was associated with a redistribution of both blood flow and ventilation in the lungs, which affected the arterial PO2 [52-55]. While it is interesting to observe a difference in the interaction between subjects and environment, the details of such mechanisms are outside the scope of our current study.
Correlation between cerebral hemodynamic responses and RGE metrics
Fig 2A shows the time series of ΔCBFv in left MCA and physiological changes including bER, ΔPO2, ΔPCO2, ToB, PETO2 and PETCO2 in a representative subject under breath hold challenge, while Fig 2B shows the time series of ΔBOLD in left gray matter, and the corresponding changes in RGE metrics in the same representative subject. The time series of bER followed the ΔCBFv and ΔBOLD closely in the subject. By visual inspection of the time series of ΔCBFv and ΔBOLD, the interpolated values of PETCO2 and ΔPCO2 during breath hold periods did not necessarily follow the changes of ΔCBFv and ΔBOLD.
Fig 2
Time series of cerebral hemodynamic responses and RGE metrics in a representative subject under breath hold challenge.
(A) Time series of ΔCBFv in left MCA and physiological changes including breath-by-breath bER, ΔPO2, ΔPCO2, ToB, PETO2 and PETCO2 in a representative subject under breath hold challenge in TCD session. (B) Time series of ΔBOLD in left gray matter (LGM) and the corresponding physiological changes in the same representative subject under breath hold challenge in MRI session. Shaded areas represent breath hold periods. The time series of bER followed closely to the ΔCBFv and ΔBOLD changes, while ΔPCO2 did not follow ΔCBFv and ΔBOLD changes some time during the challenges as indicated by two-headed arrows in red. Thin green lines represent partial pressure of O2, while the thin blue lines represent partial pressure of CO2. Thick green lines and thick blue lines represent PETO2 and PETCO2 respectively.
Time series of cerebral hemodynamic responses and RGE metrics in a representative subject under breath hold challenge.
(A) Time series of ΔCBFv in left MCA and physiological changes including breath-by-breath bER, ΔPO2, ΔPCO2, ToB, PETO2 and PETCO2 in a representative subject under breath hold challenge in TCD session. (B) Time series of ΔBOLD in left gray matter (LGM) and the corresponding physiological changes in the same representative subject under breath hold challenge in MRI session. Shaded areas represent breath hold periods. The time series of bER followed closely to the ΔCBFv and ΔBOLD changes, while ΔPCO2 did not follow ΔCBFv and ΔBOLD changes some time during the challenges as indicated by two-headed arrows in red. Thin green lines represent partial pressure of O2, while the thin blue lines represent partial pressure of CO2. Thick green lines and thick blue lines represent PETO2 and PETCO2 respectively.Among the four RGE metrics of bER, ΔPO2, ΔPCO2 and ToB, bER is the only parameter that consistently showed strong correlation with the ΔCBFv measured in left and right MCAs (Pearson's r, 0.40–0.89, p<0.001) (Fig 3A). The bER also correlated with ΔBOLD extracted from gray (LGM and RGM) and white matter (LWM and RWM) under breath hold challenge (Pearson's r, 0.21–0.83, p<0.05), except one subject in the left brain (Pearson's r, -0.011–0.18, p>0.05) (Fig 3A). The results of correlation analyses between cerebral hemodynamic responses and RGE metrics were summarized in S2 Table. Group comparisons of the correlation between cerebral hemodynamic responses (ΔCBFv and ΔBOLD) and RGE metrics (bER, ΔPO2, ΔPCO2 and ToB) also showed that the correlation between cerebral hemodynamic responses and bER was significantly stronger than those between cerebral hemodynamic responses and the RGE metrics other than bER (S2 Table). Although ToB was not as good as bER in correlating with ΔCBFv or ΔBOLD, it was better than ΔPCO2 to serve as an indicator of the breath hold periods.
Fig 3
Correlation and coherence between cerebral hemodynamic responses and RGE metrics in all subjects under breath hold challenge.
(A) Strength of correlation between cerebral hemodynamic responses and respiratory metrics including bER, ΔPO2, ΔPCO2 and ToB. Top panel shows the correlation with ΔCBFv in LMCA and RMCA (n = 12), the middle panel shows the correlation with ΔBOLD in LGM and RGM (n = 16), and the bottom panel shows the correlation with ΔBOLD in LWM and RWM (n = 16). Each grey circle represents the Pearson’s correlation coefficient from the correlation analysis of the parameter pairs shown on x-axis for each subject. The thick horizontal black line, the box and the vertical rod represent the mean, 95% confidence interval and standard deviation of the group data respectively. The cerebral hemodynamic responses correlate with the respiratory metrics consistently in a descending order of bER, ΔPO2, ToB and ΔPCO2. (B) Distribution of time-averaged coherence at the phase lag 0±π/2 between time series of respiratory metrics (bER, ΔPO2, ΔPCO2 and ToB) and cerebral hemodynamic responses. Top panel shows the coherence with ΔCBFv in LMCA and RMCA (n = 12), the middle panel shows the coherence with ΔBOLD in LGM and RGM (n = 16), and the bottom panel shows the coherence with ΔBOLD in LWM and RWM (n = 16). The mean time-averaged coherence in the frequency bandwidths from 0.008 to 0.25Hz were plotted (thick color lines). Color shaded areas represent standard error of the mean. The mean time-averaged coherence between bER and cerebral hemodynamic responses reached 0.6 or above at the frequency range from 0.008Hz (1/128 seconds) to 0.03Hz (1/32 seconds), while the mean time-averaged coherence between ΔPCO2 and cerebral hemodynamic responses stayed below 0.4. Comparing with ΔPCO2, the mean time-averaged coherence of ΔPO2 with cerebral hemodynamic responses reached 0.5 or above in the frequency range of 0.008–0.03Hz, which was better than that of ΔPCO2.
Correlation and coherence between cerebral hemodynamic responses and RGE metrics in all subjects under breath hold challenge.
(A) Strength of correlation between cerebral hemodynamic responses and respiratory metrics including bER, ΔPO2, ΔPCO2 and ToB. Top panel shows the correlation with ΔCBFv in LMCA and RMCA (n = 12), the middle panel shows the correlation with ΔBOLD in LGM and RGM (n = 16), and the bottom panel shows the correlation with ΔBOLD in LWM and RWM (n = 16). Each grey circle represents the Pearson’s correlation coefficient from the correlation analysis of the parameter pairs shown on x-axis for each subject. The thick horizontal black line, the box and the vertical rod represent the mean, 95% confidence interval and standard deviation of the group data respectively. The cerebral hemodynamic responses correlate with the respiratory metrics consistently in a descending order of bER, ΔPO2, ToB and ΔPCO2. (B) Distribution of time-averaged coherence at the phase lag 0±π/2 between time series of respiratory metrics (bER, ΔPO2, ΔPCO2 and ToB) and cerebral hemodynamic responses. Top panel shows the coherence with ΔCBFv in LMCA and RMCA (n = 12), the middle panel shows the coherence with ΔBOLD in LGM and RGM (n = 16), and the bottom panel shows the coherence with ΔBOLD in LWM and RWM (n = 16). The mean time-averaged coherence in the frequency bandwidths from 0.008 to 0.25Hz were plotted (thick color lines). Color shaded areas represent standard error of the mean. The mean time-averaged coherence between bER and cerebral hemodynamic responses reached 0.6 or above at the frequency range from 0.008Hz (1/128 seconds) to 0.03Hz (1/32 seconds), while the mean time-averaged coherence between ΔPCO2 and cerebral hemodynamic responses stayed below 0.4. Comparing with ΔPCO2, the mean time-averaged coherence of ΔPO2 with cerebral hemodynamic responses reached 0.5 or above in the frequency range of 0.008–0.03Hz, which was better than that of ΔPCO2.The mean time-averaged coherence between time series of RGE metrics (bER, ΔPO2, ΔPCO2 and ToB) and cerebral hemodynamic responses (ΔCBFv and ΔBOLD) was found to be significantly stronger between 0.008Hz (1/128 seconds) and 0.03Hz (1/32 seconds) at phase lag of 0±π/2 (S3 Fig). We therefore focused on the distribution of time-averaged coherence between RGE metrics and cerebral hemodynamic responses at the phase lag of 0±π/2 (Fig 3). Among the 4 RGE metrics, the mean time-averaged coherence between bER and cerebral hemodynamic responses at phase lag of 0±π/2 was the strongest at the frequency bandwidths of 0.008–0.03 Hz while that between ΔPCO2 and cerebral hemodynamic responses was the weakest at the same frequency bandwidths. The mean time-averaged coherence between bER, ΔPO2, ToB and cerebral hemodynamic responses at phase lag of 0±π/2 reached 0.6 or above. at the frequency bandwidths of 0.008–0.03 Hz. The correlation and dynamic coherence results suggest that CBFv and BOLD signals oscillated with bER at a broad frequency range of low frequencies when the subjects were performing breath hold task. The differences in the correlation and coherence findings between ΔPO2 and ΔPCO2 further suggest that changes of PO2 and PCO2 are not simply the inverse of each other.Fig 4 shows the regional CVR brain maps averaged across 16 subjects who performed breath hold task in MRI sessions. Under breath hold challenge, most of the brain regions showed significant increase in CVRBH-bER and CVRBH-ToB especially in thalamus, insula and putamen, while no significant changes of CVRBH-PETCO2 were observed in the same subject group (Fig 4).
Fig 4
Group CVR maps (CVRBH-PETCO2, CVRBH-ToB and CVRBH-bER) generated by regressing ΔBOLD separately on PETCO2, ToB and bER under breath hold challenges (n = 16).
All the CVR maps had been corrected for pfdr<0.05. Maps of CVRBH-ToB and CVRBH-bER were comparable, while PETCO2 was not able to characterize the regional ΔBOLD.
Group CVR maps (CVRBH-PETCO2, CVRBH-ToB and CVRBH-bER) generated by regressing ΔBOLD separately on PETCO2, ToB and bER under breath hold challenges (n = 16).
All the CVR maps had been corrected for pfdr<0.05. Maps of CVRBH-ToB and CVRBH-bER were comparable, while PETCO2 was not able to characterize the regional ΔBOLD.In the comparison of CVR brain maps under breath hold and exogenous CO2 challenge, a subset of 10 subjects who participated in both challenges were included. Under exogenous CO2 challenge, most of the brain regions showed increased CVRCO2-PETCO2 in the subject group especially thalamus, insula and putamen (Fig 5A), and the vCVRCO2-PETCO2 which had significant CVRCO2-PETCO2 changes exceeded 80% in most of the brain regions (Fig 5B). For the same group of subjects under breath hold challenge, increased CVRBH-bER and CVRBH-ToB were found in most of the brain regions, while no significant changes of CVRBH-PETCO2 were shown in most of the brain regions (Fig 5A). CVR brain maps under breath hold challenge shown in Fig 5A (n = 10) were consistent with those shown in Fig 4 (n = 16). Comparing with the vCVRBH-ToB and vCVRBH-PETCO2, vCVRBH-bER showed the largest percentage of voxels with significant CVR changes in different brain regions, implying a significantly high precision of bER predicting regional ΔBOLD in breath hold challenge (Fig 5B). The paired comparison between vCVRCO2-PETCO2 and vCVRBH-bER, as well as that between vCVRCO2-PETCO2 and vCVRBH-ToB, did not show significant difference in most of the brain regions, while significant differences were found in most of the brain regions between vCVRCO2-PETCO2 and vCVRBH-PETCO2 (Fig 5C). Such findings suggest that bER in breath hold challenge is more appropriate to be used as vasoactive stimulus than PETCO2 in assessing regional CVR under breath hold challenge.
Fig 5
Comparison of group CVR maps under exogenous CO2 challenge with those under breath hold challenge.
(A) Group CVR showing significant CVR changes under exogenous CO2 and breath hold challenges (n = 10). Group map of CVRBH-PETCO2 indicated that ΔBOLD in most of the brain regions did not associate with changes of PETCO2 under breath hold challenge. (B) Group vCVR maps showing percentage of voxels with significant CVR changes under exogenous CO2 and breath hold challenges for the same group of subjects (n = 10). The percentage of voxels with significant CVR changes under breath hold challenge were found in an increasing order of vCVRBH-PETCO2, vCVRBH-ToB and vCVRBH-bER. CVRBH-bER and vCVRBH-bER showed large resemblance with CVRCO2-PETCO2 and vCVRCO2-PETCO2 respectively. (C) Paired comparisons of vCVR maps showed that vCVRCO2-PETCO2 maps under exogenous CO2 challenge were not significantly different from vCVRBH-bER maps under breath hold challenge. Group map of vCVRBH-PETCO2 showed that ΔBOLD in only small number of voxels within the brain regions associated with the PETCO2 changes under breath hold challenge, resulting in significant differences found in multiple brain regions in the paired comparison between vCVRCO2-PETCO2 and vCVRBH-PETCO2.
Comparison of group CVR maps under exogenous CO2 challenge with those under breath hold challenge.
(A) Group CVR showing significant CVR changes under exogenous CO2 and breath hold challenges (n = 10). Group map of CVRBH-PETCO2 indicated that ΔBOLD in most of the brain regions did not associate with changes of PETCO2 under breath hold challenge. (B) Group vCVR maps showing percentage of voxels with significant CVR changes under exogenous CO2 and breath hold challenges for the same group of subjects (n = 10). The percentage of voxels with significant CVR changes under breath hold challenge were found in an increasing order of vCVRBH-PETCO2, vCVRBH-ToB and vCVRBH-bER. CVRBH-bER and vCVRBH-bER showed large resemblance with CVRCO2-PETCO2 and vCVRCO2-PETCO2 respectively. (C) Paired comparisons of vCVR maps showed that vCVRCO2-PETCO2 maps under exogenous CO2 challenge were not significantly different from vCVRBH-bER maps under breath hold challenge. Group map of vCVRBH-PETCO2 showed that ΔBOLD in only small number of voxels within the brain regions associated with the PETCO2 changes under breath hold challenge, resulting in significant differences found in multiple brain regions in the paired comparison between vCVRCO2-PETCO2 and vCVRBH-PETCO2.
Discussion
Our findings show a strong positive correlation between the cerebral hemodynamic responses and our new breath-by-breathO2-CO2 exchange ratio, in short bER, under brief breath hold challenge. We are the first to show that the dynamic changes in bER robustly characterized CBFv and BOLD responses much better than changes in PETCO2 or ToB under breath hold challenge in the very low frequency range of 0.008–0.03Hz. The difference between bER and ΔPCO2 in coherence with cerebral hemodynamic responses within the frequency range of 0.008–0.03 Hz cannot be attributed to the long periods of the breath hold protocol alone since the influence of the periods of the breath hold protocol should contribute equally to all RGE metrics. During breath holding, we presented the combined effect of both hypoxia and hypercapnia on the cerebral hemodynamic responses measured using TCD and BOLD-fMRI. Given that the concurrent changes of PETO2 and PETCO2 are in opposite direction and the magnitudes depend on the respiratory phase and volume, ΔPO2 and ΔPCO2 were in phase and selected here to more conveniently characterize the breath-by-breath changes during breath holding and spontaneous breathing epochs. bER was selected with the O2 term as the numerator of the O2/CO2 ratio due to bER’s positive temporal relationship with CBF changes. In characterizing regional BOLD signal changes to brief breath hold challenge, bER which took into account the interaction of ΔPO2 and ΔPCO2 yielded much better results than what PETCO2 and ToB could do as we showed that the brain regions outlined by bER during brief breath hold challenge were comparable with those outlined by the PETCO2 during exogenous CO2 challenge.
Mild hypoxia enhances sensitivity of CBF changes to CO2
During breath holding periods, the CO2 release are dependent on O2 uptake in the closed circuit of systemic circulation created by holding one’s breath. The interaction between ΔPO2 and ΔPCO2 during breath hold is mainly resulting from the systemic metabolic process and different from the effect of exogenous gas administration which is primarily indicated by an increase in ΔPCO2. In the current study, ΔPO2 could go from 11 to 51 mmHg and ΔPCO2 could go from 2 to 10 mmHg at the end of 30 seconds of breath holding in the TCD and MRI sessions (Tables 2 and 3). This relatively modest level of change in ΔPO2 had been reported to be able to induce a progressive increase of CBF in the presence of mild hypercapnia [27, 28]. Our findings of ΔPO2 vs. ΔPCO2 support the synergistic effect of hypoxia and hypercapnia on CBF change under breath hold challenge which are in parallel with the increased chemoreceptor activities in the presence of both mild hypoxia and mild hypercapnia reported by several research teams on animal models [15, 17, 18, 56]. Sensitivity of peripheral chemoreceptor at carotid body to arterial PCO2 was found to increase when there was a decrease in the level of arterial PO2 in these studies [15, 17, 18, 56]. The chemoreceptor activity in response to arterial PO2 took place at all levels of PO2 ranging from hypoxia to normoxia and then up to 190mmHg or even higher in the range of hyperoxia. The chemoreceptor response curve to PO2 was similar to a hyperbola with chemoreceptor activity rising faster under hypoxia (below 95mmHg) than under normoxia or hyperoxia [56]. Modulation of peripheral chemoreceptor activities may be expected leading to modulation of CBF while their physiological mechanisms remain to be clarified.
Wavelet transform coherence (WTC) analysis showed strong coherence between bER and cerebral hemodynamic responses (ΔCBFv and ΔBOLD) under breath hold challenge
We used wavelet transform coherence analysis to examine the temporal features and frequency characteristics of bER, ΔPO2, ΔPCO2 and ToB, and their coherence with CBFv and BOLD signal changes under breath hold challenge. Using WTC, we showed that the coherence between cerebral hemodynamic responses (both ΔCBFv and ΔBOLD) and change in bER was much stronger than that between cerebral hemodynamic responses and change in ΔPCO2 in a wide frequency range of 0.008–0.03Hz (Fig 3). The meaning of the range of 0.008–0.03Hz is best appreciated by examining the WTC findings which showed that bER and ΔPCO2 were very different in the frequency distribution of their coherence with cerebral hemodynamic responses. The special characteristics of the frequency range of 0.008–0.03Hz need to be considered in the context of each individual RGE metric (ΔPO2, ΔPCO2 and bER) separately.Comparing with ΔPCO2, the stronger coherence found between bER and cerebral hemodynamic responses in low frequency range of 0.008–0.03Hz may be associated with low frequency physiological processes in the brain that are grouped in B-wave frequency bandwidth. B-waves with a period of 0.5 to 2 minutes have been reported to be related to autoregulation of microvasculature and spontaneous rhythmic oscillations in intracranial pressure [57, 58]. Changes in systemic PO2 and PCO2 may trigger the underlying mechanisms which involve the interaction of central and peripheral respiratory chemoreceptors as well as autonomic system to regulate CBF. B-waves may be associated in such a process through the contractile properties of pericytes or vascular smooth muscle cells to alter vascular diameter and ensure the delivery of O2 and other circulating metabolites [59-62]. As autoregulation of CBF and oxygen delivery are the outcomes in this part of vital homeostatic process [17], it is reasonable that the stronger coupling was found between bER and cerebral hemodynamic responses, and between ΔPO2 and cerebral hemodynamic responses.In summary, among the four RGE metrics of bER, ΔPO2, ΔPCO2 and ToB, the cerebral hemodynamic responses showed the strongest correlation and dynamic coherence with bER, followed by ΔPO2, ToB, and ΔPCO2. A wide range of correlations found between ΔPO2 and ΔPCO2 (and between PETO2 and PETCO2) in the subject group, as well as the differences in the correlation in the time domain and coherence findings in wavelet transform coherence analysis between ΔPO2 and ΔPCO2 indicate that PO2 and PCO2 are not simply inverse of each other. The strong correlation between bER and ΔPO2 (S1 Fig) indicates that bER is predominantly affected by ΔPO2. ToB yielded superior correlation result than ΔPCO2 because ToB indirectly takes into account the duration for both hypoxemia and hypercapnia which both elevate cerebral hemodynamic responses without being affected by the depth of breathing. bER is the most accurate in characterizing cerebral hemodynamic responses under breath hold challenge because it directly takes into account the effect of both ΔPO2 and ΔPCO2.
CVR map from breath hold challenge resembled that from exogenous CO2 challenge
Our CVR findings showed that there was a large resemblance between regional CVRBH-bER and CVRCO2-PETCO2, even though the underlying physiological mechanisms for the CBF increase are potentially different (Fig 5). From spontaneous breathing to breath holding periods, the bER, ΔPO2 and ΔPCO2 measured were due to endogenous changes of respiratory gases involved in the process of systemic metabolism. Previous studies reported that apnea-induced hypoxia and hypercapnia caused chemoreceptor-mediated central vasodilation and concurrent peripheral vasoconstriction to conserve oxygen delivery to the brain [25], leading to an increase in CBF and a decrease in peripheral oxygen saturation [26]. Holding breath is different from exogenous CO2 administration where ΔPO2 and ΔPCO2 from normocapnic to hypercapnic epochs depended on the externally administered gas mixture and the increase in cerebral hemodynamic responses was mainly due to hypercapnia. One explanation for the large resemblance of the CVR maps between the breath hold and exogenous CO2 challenges is that bER as an optimal regressor under breath hold challenge is able to characterize the increase in cerebral hemodynamic responses in most of the brain regions. Comparing the brain maps of vCVRBH-bER with those of vCVRBH-ToB and vCVRBH-PETCO2, more voxels showed significant association between ΔBOLD and bER. For CVR maps, CVRBH-ToB resembled CVRCO2-PETCO2 more than CVRBH-PETCO2 did because ToB is a good time indicator of breath hold epochs as shown in Fig 2.Breath hold challenge, as shown in our findings in Part 2, was able to offer significant regional CVR quantification, as long as the proper regressor was used. Since bER is a measure of the dynamic change of RGE which is related to ratio of the change of partial pressure in O2 uptake to that in CO2 release in the body, mapping CVR to breath hold may offer a novel probe to study the interaction between brain responses and some measures of systemic metabolism. Mild exogenous CO2 challenge is expected to have little effect on cerebral [63] and presumably systemic metabolism. From a technical approach, breath-holding challenge for CVR assessment is much easier to set up in clinical settings than external CO2 administration which requires an elaborate gas administration circuit [6]. The breath-holding challenge also allows patients to switch back to normal breathing whenever their physiological limit is reached [64]. In patients who have compromised vasculature with potential risk of acute intracranial hemorrhage, breath-holding may offer an option for CVR study if one has some yet-to-be proven concern over the more powerful physiological stress presented by rapid increase of externally administered CO2.
Why was the ratio of ΔPO2 to ΔPCO2 used, and not the product?
The success of bER in better characterizing dynamic CBFv and BOLD signal changes under breath hold challenge is closely related to the fact that bER is a ratio which factors out at the same time effects of ventilatory volume fluctuations [32] common to both ΔPO2 and ΔPCO2. Given that both hypoxia and hypercapnia induce the increase in cerebral hemodynamic responses, one may wonder whether the product of ΔPO2 and ΔPCO2 would be better than bER for the evaluation of change in cerebral hemodynamic responses. Our answer is no. First, the product of ΔPO2 and ΔPCO2 would exacerbate the contribution of fluctuations from ventilatory volume. Secondly, unlike the ratio which has long been used to properly describe RGE since at least 1913 [65], the product does not have an established physiological meaning. Actually, another way to look at bER is that it describes the change of ΔPO2 per unit change of ΔPCO2, so the ratio provides a way to quantify how O2 and CO2 can work together to interact with cerebral hemodynamic responses.In a related framework, the ‘stimulus index’ (SI; PETCO2/PETO2) developed by Bruce et al. [66] for breath hold study is different from bER, namely ΔPO2/ΔPCO2, in its interaction with CBF. Both Bruce et al. (using SI) and our team (using bER) agree upon the influence of O2 and CO2 on CBFv change in breath hold. But there are several major differences between SI and bER.One major property that contributes to the differences between bER and SI is the direction/phase of oscillations of gas measurements. As shown in Fig 2, the time courses of PETO2 and PETCO2 oscillate out of phase, while ΔPO2 oscillates in phase with ΔPCO2. With ΔPO2 being in phase with ΔPCO2, shared but less interesting physiological signals (e.g. respiratory fluctuation) would be largely factored out in the ratio ΔPO2/ΔPCO2 (bER). With PETO2 and PETCO2 being out of phase, those less interesting physiological signals do not get factored out by PETCO2/PETO2 (SI) but can in fact be exaggerated in amplitude, as indicated by two-headed arrows in red in Figs 2 and S4. Hence those physiological fluctuations that may be less relevant with the direct interaction between cerebral hemodynamic responses and O2 or CO2 would be larger for SI than for bER. We believe that is one of the explanations for why bER is superior to SI in its correlation with CBF (S4 Fig).Another difference is that Bruce et al. [66] studied the correlation between CBF and the ratio PETCO2/PETO2 within a single prolonged period (~93 seconds) of breath holding, i.e. from the onset to the end of breath hold only. In our study, we evaluated the relationship between CBF and bER throughout the duration of six breath holding epochs (~30 seconds) and free breathing periods (~60–90 seconds). We took into account the long delayed cerebrovascular response to breath hold as CBF continues to increase shortly after the breath holding period before it slowly returns to baseline during the free breathing period. Our team reported this delayed CBF response in our other TCD study on breath hold in 2009 [67] where we showed that the time duration of CBFv response to breath hold could last twice as long as the time duration of breath hold [67]. Another team also reported the same delayed CBF response to breath hold in an MRI study [10]. That is one reason why our use of bER is expected to be superior to the use of SI developed by Bruce et al. [66] in characterizing the CBF changes in response to breath hold. The stronger positive correlation of CBFv with bER than with SI suggests that there is synergistic behavior of O2 and CO2 in bER that goes beyond what SI does.
Conclusion
Independent of our current knowledge to completely clarify why bER offers the strongest association with cerebral hemodynamic responses to breath holding, we succeeded in showing that bER was superior to ΔPCO2 or PETCO2 to characterize cerebral hemodynamic responses under breath hold challenge for the CVR evaluation. RGE metrics of both ΔPO2 and ΔPCO2 should always be acquired for CVR evaluation instead of acquiring PETCO2 data alone. In addition to offering alternative approach of CVR evaluation for patients who are not eligible for exogenous CO2 challenge, the association between bER and cerebral hemodynamic responses also provides a novel insight in the study of brain-body interaction. Future studies would be required to clarify the underlying mechanisms for the relationship between dynamic bER and cerebral hemodynamic response to breath holding. Studies to quantify the relationship between changes in cerebral hemodynamic responses during breath holding and changes in bER in a large cohort of subjects and patients would be helpful to explore the effects on CVR by various disorders including respiratory or cerebral diseases with neurovascular deficits.
Definition of end inspiration and end expiration on the time series of RGE metrics and the correlations among breath-by breath RGE matrices.
(A) A segment of 80-second time series of ΔCBFv in left MCA and physiological changes including breath-by-breath bER, ΔPO2, ΔPCO2, PETO2 and PETCO2 measured by gas analyzers and respiration time series (Resp) measured by respiratory bellow in a representative subject under breath hold challenge in TCD session. Open circles represent end expiration while closed circles represent end inspiration in resting phase or onset of expiration at the end of breath hold epoch. Positive phases with deflection above zero on the respiration time series represent inspiration and negative phases with deflection below zero represent expiration. The inspiratory and expiratory phases of each respiratory cycle on the time series of PETO2 and PETCO2 are verified by those on respiration time series. The timing for open (end expiration) and closed (end inspiration) circles in green is the same as those in red and blue. (B) Correlations among breath-by breath respiratory matrices (bER, ΔPO2, ΔPCO2, ToB, PETO2 and PETCO2) in all subjects who participated in TCD sessions (n = 12), and (C) those who participated in MRI sessions (n = 16). Each gray circle represents the Pearson’s correlation coefficient from the correlation analysis of the time series of parameter pair shown on x-axis for each subject. The thick middle horizontal line, the box and the vertical rod represent the mean, 95% confidence interval and standard deviation of the group data respectively. The time series of bER had stronger correlation with that of ΔPO2 than ΔPCO2, although both ΔPO2 and ΔPCO2 contributed to changes of bER. The correlation coefficients from ΔPO2 vs ΔPCO2 varied from 0.6 to 0.9 in TCD sessions and from 0.4 to 0.9 in MRI sessions, suggesting that ΔPO2 and ΔPCO2 are not necessarily redundant. The difference in the ranges of correlation strength found between TCD and MRI sessions may be due to the difference in posture of the subjects, where the subjects were in erect seated position in TCD sessions and they were in supine position in MRI sessions.(TIF)Click here for additional data file.
Wavelet transform coherence analysis between bER and ΔCBFv in a representative subject.
(A) Time series of bER and ΔCBFv measured in right MCA in a representative subject under breath hold challenge. (B) The squared wavelet coherence between these two time series. Squared wavelet coherence is plotted with x-axis as time and y-axis as scale which has been converted to its equivalent Fourier period. The magnitude of wavelet transform coherence ranges between 0 and 1, where warmer color represents stronger coherence and cooler color represents weaker coherence. Areas inside the ‘cone of influence’, which are locations in the time-frequency plane where edge effects give rise to lower confidence in the computed values, are shown in faded color outside of the conical contour. The statistical significance level of the wavelet coherence is estimated using Monte Carlo methods and the 5% significance level against red noise is shown as thick contour. The phase angle between the two time series at particular samples of the time-frequency plane is indicated by an arrow (rightward pointing arrows indicate that the time series are in phase or positively correlation, leftward pointing arrows indicate anticorrelation and the downward pointing arrows indicate phase angles of π/2). There are four different ranges of phase lags: 0+π/2, 0-π/2, π-π/2, and π+π/2. (C) Time-averaged coherences at four different phase lags of 0+π/2, 0-π/2, π-π/2, and π+π/2. At each phase lag range, time-averaged coherence was defined as the total significant coherence at each scale where the wavelet coherence magnitude exceeded 95% significance level, normalized by the maximum possible coherence outside the cone of influence, i.e. inside the conical contour, at that particular scale and phase lag range.(TIF)Click here for additional data file.
Coherence between time series of RGE metrics and cerebral hemodynamic response at four different phase lags (0+π/2, 0-π/2, π-π/2, and π+π/2).
The mean time-averaged coherence between time series of respiratory metrics and cerebral hemodynamic responses (ΔCBFv in LMCA and RMCA, and ΔBOLD in LGM, RGM, LWM and RWM) at four different phase lags (0+π/2, 0-π/2, π-π/2, and π+π/2) for the subjects included in the TCD sessions (n = 12) and in the MRI sessions (n = 16). Color shaded areas represent SEM. Comparing with ΔPO2, ΔPCO2 and ToB, the total time-averaged coherence between bER and cerebral hemodynamic responses was found to be significantly stronger between 0.008Hz (1/128 seconds) and 0.03Hz (1/32 seconds). The strong mean time-averaged coherence between respiratory metrics and cerebral hemodynamic responses were found at phase lag of 0+π/2.(TIF)Click here for additional data file.
Time series of cerebral hemodynamic responses, bER and PETCO2/PETO2 in a representative subject under breath hold challenge.
Time series of ΔCBFv in left MCA, bER and PETCO2/PETO2 in the same representative subject in Fig 2A under breath hold challenge in TCD session. Shaded areas represent breath hold periods. The time series of bER followed closely to the ΔCBFv changes, while PETCO2/PETO2 did not follow ΔCBFv changes some time during the challenge as indicated by two-headed arrow in red. In the time period between 400 and 580 seconds (as indicated by two-headed arrow) when the subject had shallow breathing, the amplitude of PETCO2/PETO2 decreased significantly in comparison with that of bER. This may be attributed to the different property of gas measurements where the time series of ΔPO2 and ΔPCO2 oscillated in phase while those of PETO2 and PETCO2 oscillated out of phase (Fig 2A). PETCO2 was decreased and PETO2 was increased by shallow breathing, resulting in a significant decrease in PETCO2/PETO2.(TIF)Click here for additional data file.
Correlation among RGE metrics.
Strength of correlation indicated by Pearson’s correlation coefficients among respiratory metrics including bER, ΔPO2, ΔPCO2, ToB, PETO2 and PETCO2 in all subjects who participated in TCD sessions (n = 12), and those who participated in MRI sessions (n = 16). The time series of bER had stronger correlation with that of ΔPO2 than ΔPCO2, although both ΔPO2 and ΔPCO2 contributed to changes of bER. The correlation coefficients from ΔPO2 vs ΔPCO2 varied from 0.6 to 0.9 in TCD sessions and from 0.4 to 0.9 in MRI sessions, suggesting that ΔPO2 than ΔPCO2 are not necessarily redundant.(DOCX)Click here for additional data file.A. Correlation between RGE metrics and ΔCBFv in TCD sessions. Strength of correlation indicated by Pearson’s correlation coefficients between ΔCBFv and RGE metrics including bER, ΔPO2, ΔPCO2 and ToB (n = 12). Numbers in brackets next to Pearson’s correlation coefficients indicate p values from individual correlation analyses. The bottom row shows the mean values of Fisher Z scores transformed from Pearson’s correlation coefficients in groups. Numbers in brackets next to mean Fisher Z scores indicate p values in the paired comparisons. The correlation between ΔCBFv and bER was significantly larger than those of the correlation between ΔCBFv and the other respiratory metrics in the paired comparisons (p<0.001). bER is the only parameter that consistently showed significantly high correlation with the ΔCBFv measured in LMCA and RMCA. B. Correlation between RGE metrics and ΔBOLD in MRI sessions. Strength of correlation indicated by Pearson’s correlation coefficients between ΔBOLD and RGE metrics including bER, ΔPO2, ΔPCO2 and ToB (n = 16). Numbers in brackets next to Pearson’s correlation coefficients indicate p values from individual correlation analyses. The bottom row shows the mean values of Fisher Z scores transformed from Pearson’s correlation coefficients in groups. Numbers in brackets next to mean Fisher Z scores indicate p values in paired comparisons. The correlation between ΔBOLD and bER was significantly larger than those of the correlation between ΔBOLD and the other respiratory metrics in the paired comparisons (p<0.001). bER is the only parameter that consistently showed significantly high correlation with the ΔBOLD measured in LGM, RGM, LWM and RWM.(DOCX)Click here for additional data file.19 Dec 2019PONE-D-19-31336Cerebrovascular reactivity assessment with O2-CO2 exchange ratio under brief breath hold challengePLOS ONEDear Chan,Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process.We would appreciate receiving your revised manuscript by Feb 02 2020 11:59PM. When you are ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file.If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter.To enhance the reproducibility of your results, we recommend that if applicable you deposit your laboratory protocols in protocols.io, where a protocol can be assigned its own identifier (DOI) such that it can be cited independently in the future. For instructions see: http://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocolsPlease include the following items when submitting your revised manuscript:A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). This letter should be uploaded as separate file and labeled 'Response to Reviewers'.A marked-up copy of your manuscript that highlights changes made to the original version. This file should be uploaded as separate file and labeled 'Revised Manuscript with Track Changes'.An unmarked version of your revised paper without tracked changes. This file should be uploaded as separate file and labeled 'Manuscript'.Please note while forming your response, if your article is accepted, you may have the opportunity to make the peer review history publicly available. The record will include editor decision letters (with reviews) and your responses to reviewer comments. If eligible, we will contact you to opt in or out.We look forward to receiving your revised manuscript.Kind regards,Shigehiko OgohAcademic EditorPLOS ONEAdditional Editor Comments:Chan et all investigated novel ways of quantifying cerebrovascular reactivity in response to acute perturbations in blood gases. This study was basically a methods study, investigating new metrics and comparing measurement techniques. However, the background, rational and hypothesis difficult to follow, and would suggest the authors more clearly lay out their study for the sake of the reader.Major CommentsIn both the abstract and the introduction, it it difficult to track the rationale and study design. It felt like a bit of a post-hoc packaging decision following data collection of two studies, as opposed to an a priori developed study to investigate a specific question(s). For example, a well-written introduction would lay out related background information, with one main topic per paragraph, leading intuitively to a clear rationale(s) (i.e., what is not known), then aims and specific directional hypotheses. Instead, the authors pepper up to five separate hypotheses throughout the introduction. The introduction only ends with a statement about potential significance. I feel the introduction needs a major re-write for clarity in relevant background, rationale, aim and hypothesis. I recognize that methods papers are difficult to frame in the same way as experimental papers, but it would be helpful if the authors more clearly outlined the rationale, with references, why they sought to develop novel metrics.The authors are making a claim that they have developed a novel metric to assess CVR. However, I would question both the relevance claim and the novelty claim. The bER metrics is basically just a breath-by-breath inverse of RER, as they indicate, which is interesting. I can understand the need for higher temporal resolution on a breath-by-breath basis, but the inverse nature of their metric is confusing. RER is quantified as a given amount of CO2 created (and expired) for a given amount of O2 consumed, and tells us something about what fuel is being utilized to the metabolic rate. Indeed, on the point that both CO2 and O2 are relevant to cerebrovascular response to breath holding, I agree, as do others. I find it inexplicable to inverse this metric. Why express bER as O2/CO2? Further, in terms of both respiratory and cerebrovascular responses to blood gases, CBF is directly proportional to changes in CO2, and inversely proportional to O2 and/or SaO2. Thus, this reviewer feels that the bER being arranged as inverse of both RER and known physiological responses unjustifiable.I also question the novelty of this app[roach. Indeed, Luacs et al 2011 (J Physiol) assessed CBF with a similar O2/CO2 relationship during ascent to high altitude. I feel they got the relationship backward, as per my comments above. In addition, Bruce et al 2016 (Exp Physiol) developed a technique to assess CBF responses to breath holding taking into account instantaneous changes in CO2 and O2, indexing CBV against a breath-by-breath stimulus index (SI; CO2/O2). They interpolated these gases from those at the beginning and end of a breath hold, which is basically your delta measures, I believe. Lafave et al 2019 (EJAP) utilized this SI during ascent to high altitude.As you measured MAP, if you wanted to go all the way, why no express breath-by-breath cerebrovascular conductance (CVC = CBV/MAP).Minor CommentsPlease refer to TCD metrics as cerebral blood velocity or CBV, throughout. There is no such thing as cerebral blood flow velocity.Journal requirements:When submitting your revision, we need you to address these additional requirements.1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found athttp://www.journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and http://www.journals.plos.org/plosone/s/file?id=ba62/PLOSOne_formatting_sample_title_authors_affiliations.pdf2. We note that you have indicated that data from this study are available upon request. PLOS only allows data to be available upon request if there are legal or ethical restrictions on sharing data publicly. For information on unacceptable data access restrictions, please see http://journals.plos.org/plosone/s/data-availability#loc-unacceptable-data-access-restrictions.In your revised cover letter, please address the following prompts:a) If there are ethical or legal restrictions on sharing a de-identified data set, please explain them in detail (e.g., data contain potentially identifying or sensitive patient information) and who has imposed them (e.g., an ethics committee). Please also provide contact information for a data access committee, ethics committee, or other institutional body to which data requests may be sent.b) If there are no restrictions, please upload the minimal anonymized data set necessary to replicate your study findings as either Supporting Information files or to a stable, public repository and provide us with the relevant URLs, DOIs, or accession numbers. Please see http://www.bmj.com/content/340/bmj.c181.long for guidelines on how to de-identify and prepare clinical data for publication. For a list of acceptable repositories, please see http://journals.plos.org/plosone/s/data-availability#loc-recommended-repositories.We will update your Data Availability statement on your behalf to reflect the information you provide.3. PLOS requires an ORCID iD for the corresponding author in Editorial Manager on papers submitted after December 6th, 2016. Please ensure that you have an ORCID iD and that it is validated in Editorial Manager. To do this, go to ‘Update my Information’ (in the upper left-hand corner of the main menu), and click on the Fetch/Validate link next to the ORCID field. This will take you to the ORCID site and allow you to create a new iD or authenticate a pre-existing iD in Editorial Manager. Please see the following video for instructions on linking an ORCID iD to your Editorial Manager account: https://www.youtube.com/watch?v=_xcclfuvtxQ4. Thank you for stating the following in the Financial Disclosure section:'This research was carried out in whole at the Athinoula A. Martinos Center for Biomedical Imaging at the Massachusetts General Hospital, using resources provided by the Center for Functional Neuroimaging Technologies, P41EB015896, a P41 Biotechnology Resource Grant supported by the National Institute of Biomedical Imaging and Bioengineering (NIBIB), National Institutes of Health, as well as the Shared Instrumentation Grant S10RR023043. This work was also supported, in part, by NIH-K23MH086619. 'We note that one or more of the authors are employed by a commercial company: Biogen Inc.a. Please provide an amended Funding Statement declaring this commercial affiliation, as well as a statement regarding the Role of Funders in your study. If the funding organization did not play a role in the study design, data collection and analysis, decision to publish, or preparation of the manuscript and only provided financial support in the form of authors' salaries and/or research materials, please review your statements relating to the author contributions, and ensure you have specifically and accurately indicated the role(s) that these authors had in your study. You can update author roles in the Author Contributions section of the online submission form.Please also include the following statement within your amended Funding Statement.“The funder provided support in the form of salaries for authors [insert relevant initials], but did not have any additional role in the study design, data collection and analysis, decision to publish, or preparation of the manuscript. The specific roles of these authors are articulated in the ‘author contributions’ section.”If your commercial affiliation did play a role in your study, please state and explain this role within your updated Funding Statement.b. Please also provide an updated Competing Interests Statement declaring this commercial affiliation along with any other relevant declarations relating to employment, consultancy, patents, products in development, or marketed products, etc.Within your Competing Interests Statement, please confirm that this commercial affiliation does not alter your adherence to all PLOS ONE policies on sharing data and materials by including the following statement: "This does not alter our adherence to PLOS ONE policies on sharing data and materials.” (as detailed online in our guide for authors http://journals.plos.org/plosone/s/competing-interests) . If this adherence statement is not accurate and there are restrictions on sharing of data and/or materials, please state these. Please note that we cannot proceed with consideration of your article until this information has been declared.c. Please include both an updated Funding Statement and Competing Interests Statement in your cover letter. We will change the online submission form on your behalf.Please know it is PLOS ONE policy for corresponding authors to declare, on behalf of all authors, all potential competing interests for the purposes of transparency. PLOS defines a competing interest as anything that interferes with, or could reasonably be perceived as interfering with, the full and objective presentation, peer review, editorial decision-making, or publication of research or non-research articles submitted to one of the journals. Competing interests can be financial or non-financial, professional, or personal. Competing interests can arise in relationship to an organization or another person. Please follow this link to our website for more details on competing interests: http://journals.plos.org/plosone/s/competing-interests5. We note that you have included the phrase “data not shown” in your manuscript. Unfortunately, this does not meet our data sharing requirements. PLOS does not permit references to inaccessible data. We require that authors provide all relevant data within the paper, Supporting Information files, or in an acceptable, public repository. Please add a citation to support this phrase or upload the data that corresponds with these findings to a stable repository (such as Figshare or Dryad) and provide and URLs, DOIs, or accession numbers that may be used to access these data. Or, if the data are not a core part of the research being presented in your study, we ask that you remove the phrase that refers to these data.[Note: HTML markup is below. Please do not edit.]Reviewers' comments:Reviewer's Responses to QuestionsComments to the Author1. Is the manuscript technically sound, and do the data support the conclusions?The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented.Reviewer #1: Yes**********2. Has the statistical analysis been performed appropriately and rigorously?Reviewer #1: Yes**********3. Have the authors made all data underlying the findings in their manuscript fully available?The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified.Reviewer #1: Yes**********4. Is the manuscript presented in an intelligible fashion and written in standard English?PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here.Reviewer #1: Yes**********5. Review Comments to the AuthorPlease use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters)Reviewer #1: Breath hold challenge is a simple vasoactive stimulus for the assessment of cerebrovascular reactivity (CVR) that is used in the clinic as well as exogenous CO2 challenge (hypercapnia test). The authors of the manuscript have demonstrated that the cerebrovascular response to brief breath hold hypercapnia test, used in neuro-intensive care, are coupled not only with the increased partial pressure of carbon dioxide (as it was believed before) but also with a decrease in the partial pressure of oxygen. These findings suggest that mild hypercapnia could increase the sensitivity of the CBF response to a very mild level of hypoxia and the ranges of mild PO2 and PCO2 changes reported are achievable by breath hold. This is of great importance as it means that the physiological mechanisms of cerebrovascular changes underlying breath hold and exogenous CO2 challenges are potentially different. The authors found that the breath-by-breathO2-CO2 exchange ratio (bER), namely the ratio of changes in PO2 (∆PO2) to changes in PCO2 (∆PCO2) between end inspiration and end expiration, was superior to either ∆PO2 or ∆PCO2 alone in coupling with the changes of CBFv and BOLD signals under breath hold challenge. Thus, bER would be able to better characterize CVR under breath hold challenge in the regression model without creating a problem of collinearity.**********6. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files.If you choose “no”, your identity will remain anonymous but your review may still be made public.Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy.Reviewer #1: No[NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files to be viewed.]While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email us at figures@plos.org. Please note that Supporting Information files do not need this step.23 Jan 2020Our team would like to thank for the useful comments and suggestions from the Reviewers and Editor. Please find our responses (in blue) to the Reviewers’ comments below.Major Comments:1. In both the abstract and the introduction, it is difficult to track the rationale and study design. It felt like a bit of a post-hoc packaging decision following data collection of two studies, as opposed to an a priori developed study to investigate a specific question(s). For example, a well-written introduction would lay out related background information, with one main topic per paragraph, leading intuitively to a clear rationale(s) (i.e., what is not known), then aims and specific directional hypotheses. Instead, the authors pepper up to five separate hypotheses throughout the introduction. The introduction only ends with a statement about potential significance. I feel the introduction needs a major re-write for clarity in relevant background, rationale, aim and hypothesis. I recognize that methods papers are difficult to frame in the same way as experimental papers, but it would be helpful if the authors more clearly outlined the rationale, with references, why they sought to develop novel metrics.Responses: The abstract and introduction have been rewritten based on the reviewer’s comment and suggestion. We removed the numerous sub-hypotheses distributed throughout the Introduction and raised a single hypothesis in the last paragraph of the Introduction stating that “mild hypoxia and hypercapnia work synergistically to increase CBF under breath hold challenge”. We listed our major objective after the hypothesis. Each of the preceding paragraphs presented specific background information as well as its associated rationale (i.e. what is not known).2. The authors are making a claim that they have developed a novel metric to assess CVR. However, I would question both the relevance claim and the novelty claim. The bER metrics is basically just a breath-by-breath inverse of RER, as they indicate, which is interesting. I can understand the need for higher temporal resolution on a breath-by-breath basis, but the inverse nature of their metric is confusing. RER is quantified as a given amount of CO2 created (and expired) for a given amount of O2 consumed and tells us something about what fuel is being utilized to the metabolic rate. Indeed, on the point that both CO2 and O2 are relevant to cerebrovascular response to breath holding, I agree, as do others. I find it inexplicable to inverse this metric. Why express bER as O2/CO2?Responses: We will first answer the question of bER vs. breath-by-breath RER. Both bER and RER describe the process of respiratory gas exchange. We reported that bER, but not RER, was compatible with a positive correlation with CBF (Fig 3 in original manuscript). Our data show that CBF is positively correlated with bER but negatively correlated with RER. We selected bER because a respiratory gas stimulus is conventionally expected to be positively correlated with a CBF response.CBF is described by hemodynamic surrogates CBFv and BOLD in this manuscript. Our explanation to use cerebral blood flow velocity (CBFv) instead of cerebral blood velocity (CBV) is given below in our first response to minor comments.For more clarity, it helps to repeat bER = ΔPO2/ΔPO2. ΔPO2 = (inspired PO2 – expired PO2) and ΔPCO2 = (expired PCO2 – inspired PCO2). ΔPO2 and ΔPCO2 are physiologically related to the change of gas partial pressure in systemic O2 uptake and that in CO2 release respectively.3. Further, in terms of both respiratory and cerebrovascular responses to blood gases, CBF is directly proportional to changes in CO2, and inversely proportional to O2 and/or SaO2. Thus, this reviewer feels that the bER being arranged as inverse of both RER and known physiological responses unjustifiable.I also question the novelty of this approach. Indeed, Luacs et al 2011 (J Physiol) assessed CBF with a similar O2/CO2 relationship during ascent to high altitude. I feel they got the relationship backward, as per my comments above. In addition, Bruce et al 2016 (Exp Physiol) developed a technique to assess CBF responses to breath holding taking into account instantaneous changes in CO2 and O2, indexing CBV against a breath-by-breath stimulus index (SI; CO2/O2). They interpolated these gases from those at the beginning and end of a breath hold, which is basically your delta measures, I believe. Lafave et al 2019 (EJAP) utilized this SI during ascent to high altitude.Responses: We will give a fairly long response below to the reviewer’s comment that “cerebral blood flow (CBF) is directly proportional to changes in CO2, and inversely proportional to O2 and/or SaO2,” and his associated citation of the ‘stimulus index’ (SI: PETCO2/PETO2) developed by Bruce et al. [1]. Both Bruce et al. (using SI) and our team (using bER) agree upon the influence of O2 and CO2 on CBFv change in breath hold. It is natural to wonder whether SI and bER behave in a similar way. But there are surprisingly quite a few differences between SI and bER. In our original manuscript, we thought that going into an extensive discussion about the numerous differences between Bruce et al. and us belonged to another study as we wanted to focus on characterizing and clarifying the interaction between respiratory gas exchange and CBF in breath hold. Since the reviewer is highly concerned about our work and that of Bruce et al, we now include discussion about the differences between SI and bER at the end of our revised Discussion section as well as in the Supplementary Information.The many differences between bER and SI in characterizing CBF changes in breath hold will be discussed point-by-point as follows.a) Is bER closely similar to SI in its interaction with CBF in terms of the breath hold protocol? The short answer is no. Does CBF show a stronger correlation with bER than with SI? The answer is yes. We calculated the time courses of SI (i.e. PETCO2/PETO2) using the data values on the time courses of PETCO2 and PETO2 from our representative subject in Fig 2A of the original manuscript, and correlated the values of PETCO2/PETO2 with changes of CBFv. The results are shown in S4 Fig (Supplementary Information). Our results indicate that bER is different from SI in its interaction with CBF. First, the correlation coefficient between bER and SI is 0.7 instead of being close to 1. Secondly, CBFv of the same subject correlates better with bER than SI. The stronger positive correlation of CBFv with bER than with SI suggests that there is synergistic behavior of O2 and CO2 in bER that goes beyond what SI does.b) A feature that contributes to the differences between bER and SI could be the direction/phase of oscillations of gas measurements. As shown in Fig 2 of the original manuscript, the time courses of PETO2 and PETCO2 oscillate out of phase, while ΔPO2 oscillates in phase with ΔPCO2. It is important to recognize that many less interesting physiological signals (e.g. respiratory fluctuation) are shared and carried by both O2 and CO2 time courses. With ΔPO2 being in phase with ΔPCO2, those shared physiological signals would be largely factored out in the ratio ΔPO2/ΔPCO2 (bER). With PETO2 and PETCO2 being out of phase, those less interesting physiological signals do not get factored out by SI but can in fact be exaggerated in amplitude, as indicated by two-headed arrows in red in Fig 2 and in S4 Fig (Supplementary Information). Hence those physiological fluctuations that may be less relevant with the direct interaction between cerebral hemodynamic influence and O2 or CO2 would be larger for SI than for bER. We believe that is one of the explanations for why bER is superior to SI in its correlation with CBF.For more clarity, we repeat here some of the relationship between ΔPO2, PETO2, ΔPCO2 and PETCO2. If inspired PO2 is assumed to be constant, ΔPO2 increases with decrease in PETO2. Since the PCO2 in inspired air is almost zero, ΔPCO2 is basically equivalent to PETCO2. The oscillations of ΔPO2, ΔPCO2 and PETCO2 are all in phase while PETO2 is out of phase.c) Bruce et al. studied the correlation between CBF and SI only within the period of breath holding (i.e. from the onset to the end of breath hold) by interpolating the PETCO2 and PETO2 measurements. In our study, we evaluated the relationship between CBF and bER throughout the duration of both breath holding and free breathing periods. The reason is that we take into account the long delayed cerebrovascular response to breath holding as CBF continues to increase shortly after the breath holding period before it slowly returns to baseline during the free breathing period. Our team reported this delayed CBF response in our other TCD study on breath hold in 2009 [2] where we showed that the time duration of CBFv response to breath hold could last twice as long as the time duration of breath hold (Figure 2 in Chan et al. [2]). Other teams also reported the same delayed CBF response to breath hold in an MRI study [3]. That is one reason why our use of bER is expected to be superior to the use of SI developed by Bruce et al. in characterizing the CBF changes in response to breath hold.d) Different from previous breath hold TCD studies which include the work by Bruce et al, we provided also MRI results to study BOLD responses in different brain regions as well. We are therefore able to study relationship between bER and cerebrovascular responses, both in the blood supply to the major cerebral territories using TCD and in regional BOLD responses using MRI.e) Bruce et al. included only one prolonged epoch of breath holding and the duration of breath holding lasted much more than one minute (mean psychological break-point = 93.4 sec, Table 1 in Bruce et al. [1]). In our study, we had six epochs of 30-second breath holding (Fig 1 in original manuscript) based on the consideration of the tolerability of normal subjects as well as patients. Our approach is more realistic for clinical purpose.f) Bruce et al. accepted in its Introduction section that both O2 and CO2 would have an effect on CBF during breath hold but did not raise any discussion about the long held claim in the literature that arterial PO2 needs to be around 50mmHg [4, 5] before significant CBF increase could be expected. Our manuscript explored the model on how O2 works synergistically with CO2 in raising CBF in breathhold even at relatively low level of ΔPO2. We specifically pointed out not only CBFv correlates best with bER but CBFv also correlates better with ΔPO2 than with ΔPCO2 (Fig 3 in original manuscript). The role of O2 was less explored in Bruce et al.g) Our choice of using ΔPO2 instead of end-tidal PO2 (PETO2) helps us to highlight the role of O2-CO2 exchange. The reason is that ΔPO2 and ΔPCO2 are physiologically related to the change of gas partial pressure in systemic O2 uptake and that in CO2 release respectively. In fact ΔPO2, and not PETO2, is the proper term used by Fenn et al. [6] and Ferretti [7] to express respiratory gas exchange in the alveolar air equation.Since our objective was to measure how CBFv is related to the process of respiratory gas exchange, we used the proper term ΔPO2 and not PETO2.Incidentally, RER in the alveolar air equation is usually displayed in the form of 1/RER. It is equivalent to replace 1/RER by bER averaged over time.4. As you measured MAP, if you wanted to go all the way, why no express breath-by-breath cerebrovascular conductance (CVC = CBV/MAP).Responses: The effect of mild MAP change on CBF change relates to autoregulation. At a short breath hold duration of 30 seconds with relatively mild MAP change, we prefer to focus more on the effect of of respiratory gas exchange of O2 and CO2 on CBF change in this manuscript.Minor Comments:1. Please refer to TCD metrics as cerebral blood velocity or CBV, throughout. There is no such thing as cerebral blood flow velocity.Responses: In biology community, we understand that the velocity of blood flow is usually referred to ‘blood velocity’. However, to ensure the precise communication in the imaging and neuroscience communities, we used the standard terminology of ‘blood flow velocity’ as in one of the first papers by Aaslid et al. [8] on using TCD method to measure the flow velocity in cerebral arteries. In addition, CBV in neuroimaging is commonly referred to ‘cerebral blood volume’.General Responses: Our responses to the Reviewer’s comments on SI had been incorporated into the revised Discussion section as one of the paragraphs under the subheading of “Why was the ratio of delta PO2 to delta PCO2 used, and not the product?”.Journal requirements:When submitting your revision, we need you to address these additional requirements.1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found athttp://www.journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf andhttp://www.journals.plos.org/plosone/s/file?id=ba62/PLOSOne_formatting_sample_title_authors_affiliations.pdfResponses: We revise the areas which do not match PLOS ONE’s style requirements. The affiliation of the second author (Karl Evans) is changed back to the affiliation when the study was done, i.e. Department of Psychiatry, Massachusetts General Hospital. His current address (Biogen, Inc) is included.2. We note that you have indicated that data from this study are available upon request. PLOS only allows data to be available upon request if there are legal or ethical restrictions on sharing data publicly. For information on unacceptable data access restrictions, please see http://journals.plos.org/plosone/s/data-availability#locunacceptable-data-access-restrictions.In your revised cover letter, please address the following prompts:a) If there are ethical or legal restrictions on sharing a de-identified data set, please explain them in detail (e.g.,data contain potentially identifying or sensitive patient information) and who has imposed them (e.g., an ethics committee). Please also provide contact information for a data access committee, ethics committee, or other institutional body to which data requests may be sent.b) If there are no restrictions, please upload the minimal anonymized data set necessary to replicate your study findings as either Supporting Information files or to a stable, public repository and provide us with the relevant URLs, DOIs, or accession numbers. Please see http://www.bmj.com/content/340/bmj.c181.long for guidelines on how to de-identify and prepare clinical data for publication. For a list of acceptable repositories, please see http://journals.plos.org/plosone/s/data-availability#loc-recommended-repositories.We will update your Data Availability statement on your behalf to reflect the information you provide.Responses: As the data for individual subjects were included in the Figures, Tables and Supporting Information, we amend the data availability statement as follow:‘All relevant data are within the paper and its Supporting Information files.’3. PLOS requires an ORCID iD for the corresponding author in Editorial Manager on papers submitted after December 6th, 2016. Please ensure that you have an ORCID iD and that it is validated in Editorial Manager. To do this, go to ‘Update my Information’ (in the upper left-hand corner of the main menu), and click on the Fetch/Validate link next to the ORCID field. This will take you to the ORCID site and allow you to create a new iD or authenticate a pre-existing iD in Editorial Manager. Please see the following video for instructions on linking an ORCID iD to your Editorial Manager account: https://www.youtube.com/watch?v=_xcclfuvtxQResponses: My existing ORCID has been added in ‘Update My Information’ in PLOS Editorial Manager.4. Thank you for stating the following in the Financial Disclosure section:'This research was carried out in whole at the Athinoula A. Martinos Center for Biomedical Imaging at the Massachusetts General Hospital, using resources provided by the Center for Functional Neuroimaging Technologies, P41EB015896, a P41 Biotechnology Resource Grant supported by the National Institute of Biomedical Imaging and Bioengineering (NIBIB), National Institutes of Health, as well as the Shared Instrumentation Grant S10RR023043. This work was also supported, in part, by NIH-K23MH086619. 'We note that one or more of the authors are employed by a commercial company: Biogen Inc.a. Please provide an amended Funding Statement declaring this commercial affiliation, as well as a statement regarding the Role of Funders in your study. If the funding organization did not play a role in the study design, data collection and analysis, decision to publish, or preparation of the manuscript and only provided financial support in the form of authors' salaries and/or research materials, please review your statements relating to the author contributions, and ensure you have specifically and accurately indicated the role(s) that these authors had in your study. You can update author roles in the Author Contributions section of the online submission form.Please also include the following statement within your amended Funding Statement.“The funder provided support in the form of salaries for authors [insert relevant initials], but did not have any additional role in the study design, data collection and analysis, decision to publish, or preparation of the manuscript. The specific roles of these authors are articulated in the ‘author contributions’ section.”If your commercial affiliation did play a role in your study, please state and explain this role within your updated Funding Statement.Responses: The first two funders in the statement mainly supported the MRI system for data collection, computer servers for data analysis and storage. They did not provide salary support to the authors specifically for this study. The last funder supported part of the respiratory instrumentation and disposables. Although these funders did not contribute in the study design, publish and preparation of manuscript, they contributed the equipment for data collection and analysis. The Funding Statement is amended as follow:'This research was carried out in whole at the Athinoula A. Martinos Center for Biomedical Imaging at the Massachusetts General Hospital, using resources provided by the Center for Functional Neuroimaging Technologies, P41EB015896, a P41 Biotechnology Resource Grant supported by the National Institute of Biomedical Imaging and Bioengineering (NIBIB), National Institutes of Health, as well as the Shared Instrumentation Grant S10RR023043. This work was also supported, in part, by NIH-K23MH086619. The funders had no role in study design, decision to publish, or preparation of the manuscript'The affiliation of the second author (Karl Evans) is changed back to the affiliation when the study was done, i.e. Department of Psychiatry, Massachusetts General Hospital. His current address (Biogen, Inc) is included. Biogen, Inc. is only Karl’s current affiliation and does not have any role in the study.b. Please also provide an updated Competing Interests Statement declaring this commercial affiliation along with any other relevant declarations relating to employment, consultancy, patents, products in development, or marketed products, etc.Within your Competing Interests Statement, please confirm that this commercial affiliation does not alter your adherence to all PLOS ONE policies on sharing data and materials by including the following statement: "This does not alter our adherence to PLOS ONE policies on sharing data and materials.” (as detailed online in our guide for authors http://journals.plos.org/plosone/s/competing-interests). If this adherence statement is not accurate and there are restrictions on sharing of data and/or materials, please state these. Please note that we cannot proceed with consideration of your article until this information has been declared.c. Please include both an updated Funding Statement and Competing Interests Statement in your cover letter. We will change the online submission form on your behalf.Please know it is PLOS ONE policy for corresponding authors to declare, on behalf of all authors, all potential competing interests for the purposes of transparency. PLOS defines a competing interest as anything that interferes with, or could reasonably be perceived as interfering with, the full and objective presentation, peer review, editorial decision-making, or publication of research or non-research articles submitted to one of the journals. Competing interests can be financial or non-financial, professional, or personal. Competing interests can arise in relationship to an organization or another person. Please follow this link to our website for more details on competing interests: http://journals.plos.org/plosone/s/competing-interestsResponses: The Competing Interests Statement is included in the cover letter as follow:‘The authors have declared that no competing interests exist.’5. We note that you have included the phrase “data not shown” in your manuscript. Unfortunately, this does not meet our data sharing requirements. PLOS does not permit references to inaccessible data. We require that authors provide all relevant data within the paper, Supporting Information files, or in an acceptable, public repository. Please add a citation to support this phrase or upload the data that corresponds with these findings to a stable repository (such as Figshare or Dryad) and provide and URLs, DOIs, or accession numbers that may be used to access these data. Or, if the data are not a core part of the research being presented in your study, we ask that you remove the phrase that refers to these data.Responses: The oxygen saturation data are not core part of this study. The statement is removed.While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email us at figures@plos.org. Please note that Supporting Information files do not need this step.Reviewer #1: Breath hold challenge is a simple vasoactive stimulus for the assessment of cerebrovascular reactivity (CVR) that is used in the clinic as well as exogenous CO2 challenge (hypercapnia test). The authors of the manuscript have demonstrated that the cerebrovascular response to brief breath hold hypercapnia test, used in neuro-intensive care, are coupled not only with the increased partial pressure of carbon dioxide (as it was believed before) but also with a decrease in the partial pressure of oxygen. These findings suggest that mild hypercapnia could increase the sensitivity of the CBF response to a very mild level of hypoxia and the ranges of mild PO2 and PCO2 changes reported are achievable by breath hold. This is of great importance as it means that the physiological mechanisms of cerebrovascular changes underlying breath hold and exogenous CO2 challenges are potentially different. The authors found that the breath-by-breathO2-CO2 exchange ratio (bER), namely the ratio of changes in PO2 (ΔPO2) to changes in PCO2 (ΔPCO2) between end inspiration and end expiration, was superior to either ΔPO2 or ΔPCO2 alone in coupling with the changes of CBFv and BOLD signals under breath hold challenge. Thus, bER would be able to better characterize CVR under breath hold challenge in the regression model without creating a problem of collinearity.Responses: Our team appreciates the comments from Reviewer #1.References1. Bruce CD, Steinback CD, Chauhan UV, Pfoh JR, Abrosimova M, Vanden Berg ER, et al. Quantifying cerebrovascular reactivity in anterior and posterior cerebral circulations during voluntary breath holding. Exp Physiol. 2016;101(12):1517-27.2. Chan ST, Tam Y, Lai CY, Wu HY, Lam YK, Wong PN, et al. Transcranial Doppler study of cerebrovascular reactivity: are migraineurs more sensitive to breath-hold challenge? Brain Res. 2009;1291:53-9.3. Murphy K, Harris AD, Wise RG. Robustly measuring vascular reactivity differences with breath-hold: normalising stimulus-evoked and resting state BOLD fMRI data. NeuroImage. 2011;54(1):369-79.4. Lassen NA. Cerebral blood flow and oxygen consumption in man. Physiological reviews. 1959;39(2):183-238.5. Hoiland RL, Bain AR, Rieger MG, Bailey DM, Ainslie PN. Hypoxemia, oxygen content, and the regulation of cerebral blood flow. American journal of physiology Regulatory, integrative and comparative physiology. 2016;310(5):R398-413.6. Fenn WO, Rahn H, Otis AB. A theoretical study of the composition of the alveolar air at altitude. Am J Physiol. 1946;146:637-53.7. Ferretti G. Energetics of Muscular Exercise. Switzerland: Springer International Publishing; 2015.8. Aaslid R, Markwalder TM, Nornes H. Noninvasive transcranial Doppler ultrasound recording of flow velocity in basal cerebral arteries. J Neurosurg. 1982;57(6):769-74.Submitted filename: ResponseToReviewers.docxClick here for additional data file.28 Feb 2020Cerebrovascular reactivity assessment with O2-CO2 exchange ratio under brief breath hold challengePONE-D-19-31336R1Dear Dr. Chan,We are pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it complies with all outstanding technical requirements.Within one week, you will receive an e-mail containing information on the amendments required prior to publication. When all required modifications have been addressed, you will receive a formal acceptance letter and your manuscript will proceed to our production department and be scheduled for publication.Shortly after the formal acceptance letter is sent, an invoice for payment will follow. To ensure an efficient production and billing process, please log into Editorial Manager at https://www.editorialmanager.com/pone/, click the "Update My Information" link at the top of the page, and update your user information. If you have any billing related questions, please contact our Author Billing department directly at authorbilling@plos.org.If your institution or institutions have a press office, please notify them about your upcoming paper to enable them to help maximize its impact. If they will be preparing press materials for this manuscript, you must inform our press team as soon as possible and no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org.With kind regards,Shigehiko OgohAcademic EditorPLOS ONEAdditional Editor Comments (optional):Thank you for the revised manuscript. Both reviewers are satisfied with your response.Reviewers' comments:Reviewer's Responses to QuestionsComments to the Author1. If the authors have adequately addressed your comments raised in a previous round of review and you feel that this manuscript is now acceptable for publication, you may indicate that here to bypass the “Comments to the Author” section, enter your conflict of interest statement in the “Confidential to Editor” section, and submit your "Accept" recommendation.Reviewer #2: All comments have been addressed**********2. Is the manuscript technically sound, and do the data support the conclusions?The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented.Reviewer #2: Yes**********3. Has the statistical analysis been performed appropriately and rigorously?Reviewer #2: Yes**********4. Have the authors made all data underlying the findings in their manuscript fully available?The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified.Reviewer #2: Yes**********5. Is the manuscript presented in an intelligible fashion and written in standard English?PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here.Reviewer #2: Yes**********6. Review Comments to the AuthorPlease use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters)Reviewer #2: Thank you to the authors for their thoughtful responses to my queries.The issue of how to quantify CBF responses to a breath hold stimulus is difficult, and the authors have carried out an interesting study (using two metrics of CBF), to characterize a novel metric that takes into account changes in both O2 and CO2.They have addressed my queries about organization of the introduction and their quantification technique adequately, and they explain clearly in the manuscript why the RER, SI and bER are different with respect to CBF responses, as they did in the rebuttal to me. This reconciliation between analysis techniques is useful and important.Normally, the hypothesis is the last sentence in a manuscript. The potential significance can be left to the discussion.Congratulations on an interesting study.Make sure you cite the justification of why BP was unchanged during your breath hold given other work:https://www.ncbi.nlm.nih.gov/pubmed/21521758A new study that you may be interested in was just published:https://www.ncbi.nlm.nih.gov/pubmed/32083357Other useful Refs:https://www.ncbi.nlm.nih.gov/pubmed/24081155https://www.ncbi.nlm.nih.gov/pubmed/22961068**********7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files.If you choose “no”, your identity will remain anonymous but your review may still be made public.Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy.Reviewer #2: No5 Mar 2020PONE-D-19-31336R1Cerebrovascular reactivity assessment with O2-CO2 exchange ratio under brief breath hold challengeDear Dr. Chan:I am pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now with our production department.If your institution or institutions have a press office, please notify them about your upcoming paper at this point, to enable them to help maximize its impact. If they will be preparing press materials for this manuscript, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information please contact onepress@plos.org.For any other questions or concerns, please email plosone@plos.org.Thank you for submitting your work to PLOS ONE.With kind regards,PLOS ONE Editorial Office Staffon behalf ofDr. Shigehiko OgohAcademic EditorPLOS ONE
Authors: Johan Petersson; Malin Rohdin; Alejandro Sánchez-Crespo; Sven Nyrén; Hans Jacobsson; Stig A Larsson; Sten G E Lindahl; Dag Linnarsson; Blazej Neradilek; Nayak L Polissar; Robb W Glenny; Margareta Mure Journal: Respir Physiol Neurobiol Date: 2009-02-07 Impact factor: 1.931
Authors: Christina D Bruce; Craig D Steinback; Uday V Chauhan; Jamie R Pfoh; Maria Abrosimova; Emily R Vanden Berg; Rachel J Skow; Margie H Davenport; Trevor A Day Journal: Exp Physiol Date: 2016-12-01 Impact factor: 2.969
Authors: Suk-Tak Chan; Cora Ordway; Ronald J Calvanio; Ferdinando S Buonanno; Bruce R Rosen; Kenneth K Kwong Journal: J Neurotrauma Date: 2021-07-22 Impact factor: 4.869