Accuracy of intraocular lens power calculation methods when targeting low myopia in monovision.

Andrew M J Turnbull1, Warren E Hill, Graham D Barrett.   

Abstract

PURPOSE: To investigate the accuracy of IOL power calculation methods for refractive targets of myopia compared with emmetropia.
SETTING: Lions Eye Institute, Perth, Australia.
DESIGN: Retrospective analysis.
METHODS: Patients undergoing bilateral, sequential cataract surgery with a plan of modest monovision were analyzed. Target refraction was plano (distance eye) and -1.25 diopters (D) (near eye). Prediction error was determined by comparing the actual postoperative refraction with the predicted postoperative refraction, calculated by the Barrett Universal II (BUII), Hill-RBF version 2.0 (Hill-RBF 2.0), Haigis, Holladay 1, SRK/T, and Hoffer Q formulas. The dataset was divided into distance and near eye subgroups. Mean and median absolute error and percentage of eyes within ±0.25, ±0.50, ±0.75, and ±1.00 D of refractive target were compared.
RESULTS: The study included 88 consecutive patients. There was a consistent trend for lower refractive accuracy in the near eyes. BUII and Hill-RBF 2.0 were the most accurate overall and least affected by this phenomenon, with 1 (1.1%) and 4 (4.6%) fewer eyes, respectively, in the near subgroup achieving ±0.50 D of target. Haigis and SRK/T were most affected, with 14 (15.9%) and 11 (12.5%) fewer near eyes achieving ±0.50 D of target (P < .05). Holladay 1 and Hoffer Q occupied the middle ground, with 6 (6.8%) and 9 (10.2%) fewer near eyes achieving ±0.50 D of target.
CONCLUSIONS: IOL-power calculation formulas appear to be less accurate when targeting myopia compared with emmetropia. BUII and Hill-RBF 2.0 represented good options when planning pseudophakic monovision as they were least affected by this phenomenon and can be used for both distance and near eyes.

Entities:  

Mesh:

Year:  2020        PMID: 32205728     DOI: 10.1097/j.jcrs.0000000000000187

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  4 in total

1.  The Effect of Spectacle-Induced Low Myopia in the Non-Dominant Eye on the Binocular Defocus Curve with a Non-Diffractive Extended Vision Intraocular Lens.

Authors:  Kjell G Gundersen; Richard Potvin
Journal:  Clin Ophthalmol       Date:  2021-08-24

2.  Accuracy of Intraocular Lens Power Calculation Formulas in Myopic Eyes with Target Refractions of Emmetropia and Intentional Myopia.

Authors:  Daiki Sakai; Yasuhiko Hirami; Makoto Nakamura; Yasuo Kurimoto
Journal:  Clin Ophthalmol       Date:  2021-11-27

3.  Comparison of the Accuracy of Intraoperative Aberrometry in Intraocular Lens Implantation Between Myopic Eyes with Emmetropia and Myopia Targets.

Authors:  Daiki Sakai; Sakiko Demoto; Yukako Iwai; Yasuhiko Hirami; Makoto Nakamura; Yasuo Kurimoto
Journal:  Clin Ophthalmol       Date:  2022-04-16

4.  Accuracy of Six Intraocular Lens Power Calculations in Eyes with Axial Lengths Greater than 28.0 mm.

Authors:  Majid Moshirfar; Kathryn M Durnford; Jenna L Jensen; Daniel P Beesley; Telyn S Peterson; Ines M Darquea; Yasmyne C Ronquillo; Phillip C Hoopes
Journal:  J Clin Med       Date:  2022-10-08       Impact factor: 4.964

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.