Literature DB >> 32203233

Novel body fat estimation using machine learning and 3-dimensional optical imaging.

Patrick S Harty1, Breck Sieglinger2, Steven B Heymsfield3, John A Shepherd4, David Bruner2, Matthew T Stratton1, Grant M Tinsley5.   

Abstract

Estimates of body composition have been derived using 3-dimensional optical imaging (3DO), but no equations to date have been calibrated using a 4-component (4C) model criterion. This investigation reports the development of a novel body fat prediction formula using anthropometric data from 3DO imaging and a 4C model. Anthropometric characteristics and body composition of 179 participants were measured via 3DO (Size Stream® SS20) and a 4C model. Machine learning was used to identify significant anthropometric predictors of body fat (BF%), and stepwise/lasso regression analyses were employed to develop new 3DO-derived BF% prediction equations. The combined equation was externally cross-validated using paired 3DO and DXA assessments (n = 158), producing a R2 value of 0.78 and a constant error of (X ± SD) 0.8 ± 4.5%. 3DO BF% estimates demonstrated equivalence with DXA based on equivalence testing with no proportional bias in the Bland-Altman analysis. Machine learning methods may hold potential for enhancing 3DO-derived BF% estimates.

Entities:  

Mesh:

Year:  2020        PMID: 32203233      PMCID: PMC7220828          DOI: 10.1038/s41430-020-0603-x

Source DB:  PubMed          Journal:  Eur J Clin Nutr        ISSN: 0954-3007            Impact factor:   4.016


In recent years, the use of commercially available 3-dimensional optical imaging (3DO) devices has garnered considerable interest as a potentially useful, non-invasive method to evaluate automated anthropometry and body composition for adults[1, 2] and children.[3] These devices utilize infrared and visible light to create a 3-dimensional representation of a subject’s body, allowing for rapid, automatic assessment of anthropometric characteristics.[4] Highly reliable circumference measurements have been produced by 3DO devices and can be employed in simple anthropometry-based body fat prediction equations.[5] However, the comprehensive data collected by 3DO allows for the development of more advanced prediction models that utilize additional circumferences and ratios between body segments, which may reduce the magnitude of errors caused by increasing adiposity, different body shapes, and divergent body composition phenotypes.[6] Thus, the purpose of the present investigation was to develop and cross-validate a novel body fat prediction method using anthropometric data from 3DO imaging and a reference 4-component (4C) model. One hundred and seventy-nine participants (103F, 76M; age: [X±SD] 33.6±15.3 y; BMI: 25.1±4.2 kg/m2; body fat: 26.3±8.8; 30% racial/ethnic minorities) completed duplicate assessments via 3DO, with repositioning between assessments. Each individual assessment produced five full-body scans, which were all utilized in the present analysis. The 3DO scanner employed in the present study (Size Stream® SS20; scanner version 6.0.0.32) utilizes structured light scanning with a static configuration and was calibrated daily using a manufacturer-supplied checkered calibration board. For 4C body composition estimates, body volume was obtained from air displacement plethysmography with measured lung volume (Cosmed BOD POD®), bone mineral content (BMC) from dual-energy X-ray absorptiometry (DXA) (General Electric Lunar Prodigy with enCORE software v. 16.2), total body water from bioimpedance spectroscopy (ImpediMed SFB7), and body mass (BM) from a calibrated electronic scale. All equipment was calibrated as recommended by the device manufacturers each day prior to use, and all testing occurred after an overnight food and fluid fast. Participants provided informed consent, and the aforementioned protocol was approved by the Texas Tech University Institutional Review Board. A rearrangement of the 4C equation of Wang et al.[7] was utilized to estimate body fat percentage (BF%). For 3DO and ADP assessments, participants wore minimal form fitting clothing and a swim cap. Light athletic clothing with no metal was worn for DXA and bioimpedance spectroscopy assessments. For cross-validation purposes, paired DXA (Hologic® Discovery A) and 3DO (Size Stream® SS20) assessments (n=158) were completed at two additional testing sites. Although differences between GE® and Hologic® DXA output have been reported,[8] cross-calibration was not performed for the present analysis due to the minimal use of GE® DXA variables (i.e., only BMC from the GE® scanner was used as part of the 4C model). Machine learning (i.e., decision tree analysis) was utilized to determine the significant 3DO-derived factor(s) separating higher and lower BF%, based on the 4C model data. Stepwise and lasso regression analyses were performed to develop a BF% estimation formula based on approximately 200 anthropometric measurement sites identified by the 3DO scanning software. Decision tree analysis using the fitrtree function (MATLAB, Natick, MA, USA) identified lower abdomen circumference (ACLOWER) as the primary anthropometric factor that distinguished between higher and lower BF%, with a criterion separation point of 103.5 cm (40.75 inches) (Figure 1). ACLOWER was defined as the horizontal circumference at the level of the forwardmost projection point occurring inferior to the front waist point and superior to the maximum rear seat projection. A novel appendage-to-trunk circumference index (ATI) was developed for use in the BF% prediction equations, where UA is upper arm, R and L correspond to right and left, ACUPPER corresponds to the maximal circumference superior to the waist and inferior to the chest, and all values represent circumference estimated in cm.
Figure 1.

Decision Tree Analysis.

Machine learning (i.e., decision tree analysis) identified lower abdomen circumference (AC) as the primary anthropometric factor that distinguished between higher and lower 4-component model body fat percentage, with a criterion separation point of 103.5 cm (40.75 inches). The decision tree procedures further produced the two body fat percentage equations displayed in the manuscript.

Abbreviations. AC: lower abdominal circumference in cm, ATI: appendage-to-trunk index, BSA: body surface area in cm2, TC: thigh circumference (right) in cm

Novel BF% prediction equations for individuals with ACLOWER less than 103.5 cm (3DO BF%Eq.1) and greater than 103.5 cm (3DO BF%Eq.2) were developed, where sex is coded as Male=1 and Female=0, BSA is body surface area measured in cm2, and all remaining variables are circumferences measured in cm. Thigh circumference was defined as the leg girth measured 5.1 cm (2.0 inches) below the crotch point. The developed method produced a R2 of 0.82 and a constant error (CE) of −0.15 ± 3.67% relative to 4C BF% data (Figure 2A). Cross-validation against DXA BF% produced an R2 value of 0.78, CE of −0.79 ± 4.52%, and root mean square error of 4.57% (Figure 2B). Additionally, 3DO and DXA BF% exhibited equivalence[9] based on a ±2% body fat equivalence interval and displayed no proportional bias in the Bland-Altman analysis (Figure 2C).
Figure 2.

Validation of 3DO Body Fat Estimates.

New 3DO body fat estimates were developed using paired 3DO and 4C assessments (panel A). The 3DO estimates were externally cross validated against DXA. Cross-validation indicated a small deviation from the slope of the line of identity (panel B; slope: 0.90 [95% confidence interval: 0.83, 0.98]), but no proportional bias (panel C; slope: 0.03 [95% confidence interval: −0.05, 0.10]).

Abbreviations. 3DO: 3-dimensional optical imaging, 4C: 4-component model, DXA: dual-energy x-ray absorptiometry, LOA: limits of agreement

This proof-of-concept investigation identified and validated a novel 3DO body fat prediction equation that accounts for divergent anthropometric characteristics. The combined equation was found to have acceptable validity and minimal group-level error compared to DXA, mirroring the results of Ng and colleagues,[1] who reported comparable validity of a 3DO-derived prediction equation relative to DXA fat mass estimates in a multi-ethnic, mixed-sex cohort. Taken together, these findings suggest that device-specific 3DO BF% prediction equations could serve as a suitable alternative to DXA to estimate body composition in groups of healthy individuals. While the individual-level error (i.e., 95% limits of agreement) was relatively larger, further research regarding the potential utility of 3DO for tracking individual changes in body composition is warranted. A unique feature of the present investigation is the use of the 4C model to develop the 3DO BF% prediction equation, as previous studies have not developed or validated 3DO-derived estimates using a multi-compartment model.[1, 6, 10, 11] Furthermore, the novel application of machine learning techniques to determine key anthropometric factors associated with body fat variation revealed that the optimal 3DO-derived variables to predict percent body fat differ substantially between lean and obese individuals. However, limitations of the present investigation are the small sample size for machine learning techniques, which likely did not capture the full variety of body shapes and compositions, and the necessity of utilizing few regressors to avoid overfitting. Additionally, anthropometric estimates from differing 3DO systems can vary, even for similar anatomical locations, indicating that the presented equations are likely specific to the evaluated scanner.[5] In the future, investigators and device manufacturers could use a similar approach to identify key anthropometric predictors in specific populations or in larger samples, potentially increasing the specificity, accuracy, and utility of 3DO-derived body composition estimation equations.
  5 in total

1.  A Primer on the Use of Equivalence Testing for Evaluating Measurement Agreement.

Authors:  Philip M Dixon; Pedro F Saint-Maurice; Youngwon Kim; Paul Hibbing; Yang Bai; Gregory J Welk
Journal:  Med Sci Sports Exerc       Date:  2018-04       Impact factor: 5.411

2.  Validation of a three-dimensional body scanner for body composition measures.

Authors:  Michelle M Harbin; Alexander Kasak; Joseph D Ostrem; Donald R Dengel
Journal:  Eur J Clin Nutr       Date:  2017-12-29       Impact factor: 4.016

3.  Digital anthropometry via three-dimensional optical scanning: evaluation of four commercially available systems.

Authors:  Grant M Tinsley; M Lane Moore; Jacob R Dellinger; Brian T Adamson; Marqui L Benavides
Journal:  Eur J Clin Nutr       Date:  2019-11-04       Impact factor: 4.016

4.  Children and Adolescents' Anthropometrics Body Composition from 3-D Optical Surface Scans.

Authors:  Michael C Wong; Bennett K Ng; Samantha F Kennedy; Phoenix Hwaung; En Y Liu; Nisa N Kelly; Ian S Pagano; Andrea K Garber; Dominic C Chow; Steven B Heymsfield; John A Shepherd
Journal:  Obesity (Silver Spring)       Date:  2019-11       Impact factor: 5.002

Review 5.  Digital anthropometry: a critical review.

Authors:  Steven B Heymsfield; Brianna Bourgeois; Bennett K Ng; Markus J Sommer; Xin Li; John A Shepherd
Journal:  Eur J Clin Nutr       Date:  2018-05-10       Impact factor: 4.016

  5 in total
  9 in total

1.  Anthropometric evaluation of a 3D scanning mobile application.

Authors:  Brooke Smith; Cassidy McCarthy; Marcelline E Dechenaud; Michael C Wong; John Shepherd; Steven B Heymsfield
Journal:  Obesity (Silver Spring)       Date:  2022-05-02       Impact factor: 9.298

2.  LncRNA ZNF582-AS1 Expression and Methylation in Breast Cancer and Its Biological and Clinical Implications.

Authors:  Junlong Wang; Dionyssios Katsaros; Nicoletta Biglia; Yuanyuan Fu; Chiara Benedetto; Lenora Loo; Zhanwei Wang; Herbert Yu
Journal:  Cancers (Basel)       Date:  2022-06-04       Impact factor: 6.575

3.  Digital anthropometry for body circumference measurements: Toward the development of universal three-dimensional optical system analysis software.

Authors:  Sima Sobhiyeh; Samantha Kennedy; Alexander Dunkel; Marcelline E Dechenaud; Jerome A Weston; John Shepherd; Peter Wolenski; Steven B Heymsfield
Journal:  Obes Sci Pract       Date:  2020-11-06

4.  Circumference-Based Predictions of Body Fat Revisited: Preliminary Results From a US Marine Corps Body Composition Survey.

Authors:  Adam W Potter; William J Tharion; Lucas D Holden; Angie Pazmino; David P Looney; Karl E Friedl
Journal:  Front Physiol       Date:  2022-03-31       Impact factor: 4.566

5.  Smartphone camera based assessment of adiposity: a validation study.

Authors:  Maulik D Majmudar; Siddhartha Chandra; Kiran Yakkala; Samantha Kennedy; Amit Agrawal; Mark Sippel; Prakash Ramu; Apoorv Chaudhri; Brooke Smith; Antonio Criminisi; Steven B Heymsfield; Fatima Cody Stanford
Journal:  NPJ Digit Med       Date:  2022-06-29

6.  Bioimpedance analysis combined with sagittal abdominal diameter for abdominal subcutaneous fat measurement.

Authors:  Chung-Liang Lai; Hsueh-Kuan Lu; Ai-Chun Huang; Lee-Ping Chu; Hsiang-Yuan Chuang; Kuen-Chang Hsieh
Journal:  Front Nutr       Date:  2022-08-10

7.  Normalized sensitivity of multi-dimensional body composition biomarkers for risk change prediction.

Authors:  A Criminisi; N Sorek; S B Heymsfield
Journal:  Sci Rep       Date:  2022-07-20       Impact factor: 4.996

8.  New Equations for Hydrostatic Weighing without Head Submersion.

Authors:  Jeff C Tesch; Panayiotis Papadopoulos; Forrest Dolgener; Grant M Tinsley
Journal:  J Funct Morphol Kinesiol       Date:  2022-09-16

Review 9.  Anthropometric Indicators as a Tool for Diagnosis of Obesity and Other Health Risk Factors: A Literature Review.

Authors:  Paola Piqueras; Alfredo Ballester; Juan V Durá-Gil; Sergio Martinez-Hervas; Josep Redón; José T Real
Journal:  Front Psychol       Date:  2021-07-09
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.