Liselotte F Bulstra1, Caroline A Hundepool1, Patricia F Friedrich1, Allen T Bishop1, Steven E R Hovius1, Alexander Y Shin1. 1. From the Department of Orthopedic Surgery, Division of Hand Surgery, Mayo Clinic; the Department of Plastic, Reconstructive, and Hand Surgery, Erasmus Medical Center 's-Gravendijkwal; the Department of Plastic and Reconstructive Surgery, Radboudumc University Hospital; and the Xpert Clinic for Hand and Wrist Surgery.
Abstract
BACKGROUND: Processed nerve allografts are a promising alternative to nerve autografts, providing an unlimited, readily available supply and avoiding donor-site morbidity and the need for immunosuppression. Currently, clinically available nerve allografts do not provide satisfactory results for motor reconstruction. This study evaluated motor recovery after reconstruction of a long nerve gap using a processed nerve allograft and the influence of storage techniques. METHODS: Nerve allografts were decellularized using elastase and detergents and stored at either 4° or -80°C. In 36 New Zealand White rabbits, a 3-cm peroneal nerve gap was repaired with either an autograft (group 1, control) or a cold-stored (group 2) or frozen-stored (group 3) processed nerve allograft. Nerve recovery was evaluated using longitudinal ultrasound measurements, electrophysiology (compound muscle action potentials), isometric tetanic force, wet muscle weight, and histomorphometry after 24 weeks. RESULTS: Longitudinal ultrasound measurements showed that the cold-stored allograft provided earlier regeneration than the frozen-stored allograft. Furthermore, ultrasound showed significantly inferior recovery in group 3 than in both other groups (p < 0.05). Muscle weight and isometric tetanic force showed similar outcomes in the autograft and cold-stored allograft groups [p = 0.096 (muscle weight) and p = 0.286 (isometric tetanic force)], and confirmed the inferiority of the frozen-stored allograft to the autograft [p < 0.01 (muscle weight) and p = 0.02 (isometric tetanic force)]. CONCLUSIONS: Frozen storage of the nerve allograft significantly impairs functional recovery and should be avoided. The cold-stored optimized nerve allograft yields functional recovery similar to the gold standard autograft in the reconstruction of a 3-cm motor nerve defect. Future studies should focus on further improvement of the nerve allograft.
BACKGROUND: Processed nerve allografts are a promising alternative to nerve autografts, providing an unlimited, readily available supply and avoiding donor-site morbidity and the need for immunosuppression. Currently, clinically available nerve allografts do not provide satisfactory results for motor reconstruction. This study evaluated motor recovery after reconstruction of a long nerve gap using a processed nerve allograft and the influence of storage techniques. METHODS: Nerve allografts were decellularized using elastase and detergents and stored at either 4° or -80°C. In 36 New Zealand White rabbits, a 3-cm peroneal nerve gap was repaired with either an autograft (group 1, control) or a cold-stored (group 2) or frozen-stored (group 3) processed nerve allograft. Nerve recovery was evaluated using longitudinal ultrasound measurements, electrophysiology (compound muscle action potentials), isometric tetanic force, wet muscle weight, and histomorphometry after 24 weeks. RESULTS: Longitudinal ultrasound measurements showed that the cold-stored allograft provided earlier regeneration than the frozen-stored allograft. Furthermore, ultrasound showed significantly inferior recovery in group 3 than in both other groups (p < 0.05). Muscle weight and isometric tetanic force showed similar outcomes in the autograft and cold-stored allograft groups [p = 0.096 (muscle weight) and p = 0.286 (isometric tetanic force)], and confirmed the inferiority of the frozen-stored allograft to the autograft [p < 0.01 (muscle weight) and p = 0.02 (isometric tetanic force)]. CONCLUSIONS: Frozen storage of the nerve allograft significantly impairs functional recovery and should be avoided. The cold-stored optimized nerve allograft yields functional recovery similar to the gold standard autograft in the reconstruction of a 3-cm motor nerve defect. Future studies should focus on further improvement of the nerve allograft.
Authors: Mickey S Cho; Brian D Rinker; Renata V Weber; Jerome D Chao; John V Ingari; Darrell Brooks; Gregory M Buncke Journal: J Hand Surg Am Date: 2012-11 Impact factor: 2.230
Authors: Louis H Poppler; Xueping Ee; Lauren Schellhardt; Gwendolyn M Hoben; Deng Pan; Daniel A Hunter; Ying Yan; Amy M Moore; Alison K Snyder-Warwick; Sheila A Stewart; Susan E Mackinnon; Matthew D Wood Journal: Tissue Eng Part A Date: 2016-07-07 Impact factor: 3.845
Authors: Ching-Hsuan Hu; Tommy Nai-Jen Chang; Johnny Chuieng-Yi Lu; Vincent G Laurence; David Chwei-Chin Chuang Journal: Plast Reconstr Surg Date: 2018-01 Impact factor: 4.730
Authors: Liselotte F Bulstra; Caroline A Hundepool; Patricia F Friedrich; Allen T Bishop; Steven E R Hovius; Alexander Y Shin Journal: Plast Reconstr Surg Date: 2020-06 Impact factor: 4.730
Authors: Scott J Farber; Gwendolyn M Hoben; Daniel A Hunter; Ying Yan; Philip J Johnson; Susan E Mackinnon; Matthew D Wood Journal: Muscle Nerve Date: 2016-05-27 Impact factor: 3.217
Authors: Liselotte F Bulstra; Caroline A Hundepool; Patricia F Friedrich; Allen T Bishop; Steven E R Hovius; Alexander Y Shin Journal: Plast Reconstr Surg Date: 2020-06 Impact factor: 4.730
Authors: Vijay Kumar Kuna; Andre Lundgren; Luis Oliveros Anerillas; Peyman Kelk; Maria Brohlin; Mikael Wiberg; Paul J Kingham; Ludmila N Novikova; Gustav Andersson; Lev N Novikov Journal: Int J Mol Sci Date: 2022-08-06 Impact factor: 6.208