Literature DB >> 32173325

Design and validation of a low-cost, high-fidelity model for robotic pyeloplasty simulation training.

Matthew D Timberlake1, Alaina Garbens2, Bruce J Schlomer2, Nicholas L Kavoussi3, Adam J M Kern2, Craig A Peters2, Jeffery C Gahan4.   

Abstract

INTRODUCTION/
BACKGROUND: Owing to restrictions in operative experiences, urology residents can no longer solely rely on 'hands-on' operative time to master their surgical skills by the end of residency. Simulation training could help residents master basic surgical skills and steps of a procedure to maximize time in the operative room. However, simulators can be expensive or tedious to set up, limiting the availability to residents and training programs.
OBJECTIVE: The authors sought to develop and validate an inexpensive, high-fidelity training model for robotic pyeloplasty. STUDY
DESIGN: Pyeloplasty models were created using Dragon Skin® FX-Pro tissue-mimicking silicone cast over 3-dimensional molds. Urology faculty and trainees completed a demographic questionnaire. The participants viewed a brief instructional video and then independently performed robotic dismembered pyeloplasty on the model. Acceptability and content validity were evaluated via post-task evaluation of the model. Construct validity was evaluated by comparing procedure completion time, the Global Evaluative Assessment of Robotic Skills (GEARS) score, blinded subjective physical evaluation of repair quality (1-10 scale), and flow rate between experts and novices.
RESULTS: In total, 5 urology faculty, 6 fellows, and 14 residents participated. The median robotic console experience among faculty, fellows, and residents was 8 years (interquartile range [IQR] = 6-11), 3.5 years (IQR = 2-4 years), and 0 years (IQR = 0-0.5 years), respectively. The median procedure completion time was 29 min (IQR = 26-40 min), and the median flow rate was 1.11 mL/s (IQR = 0-1.34 mL/s). All faculty had flow rates >1.25 mL/s and procedure times <30 min compared with 2 of 6 fellows and none of the residents (P < 0.001). All faculty, half of the fellows, and none of the residents achieved a GEARS score ≥20, with a median resident score of 12.5 (IQR = 8-13) (P < 0.001). For repair quality, all faculty scored ≥9 (out of 10), all fellows scored ≥8, and the median score among residents was 6 (IQR = 2-6) (P < 0.001). The material cost was $1.32/model, and the average production time was 0.12 person-hours/model. DISCUSSION AND
CONCLUSION: This low-cost pyeloplasty model exhibits acceptability and content validity. Construct validity is supported by significant correlation between participant expertise and simulator performance across multiple assessment domains. The model has excellent potential to be used as a training tool in urology and allows for repetitive practice of pyeloplasty skills before live cases. Published by Elsevier Ltd.

Entities:  

Keywords:  Pediatric urology; Reconstructive urology; Robotic surgery; Simulation training; Ureteropelvic junction obstruction

Mesh:

Year:  2020        PMID: 32173325     DOI: 10.1016/j.jpurol.2020.02.003

Source DB:  PubMed          Journal:  J Pediatr Urol        ISSN: 1477-5131            Impact factor:   1.830


  4 in total

1.  Pediatric robotic surgery: issues in management-expert consensus from the Italian Society of Pediatric and Neonatal Anesthesia and Intensive Care (SARNePI) and the Italian Society of Pediatric Surgery (SICP).

Authors:  Simonetta Tesoro; Piergiorgio Gamba; Mirko Bertozzi; Rachele Borgogni; Fabio Caramelli; Giovanni Cobellis; Giuseppe Cortese; Ciro Esposito; Tommaso Gargano; Rossella Garra; Giulia Mantovani; Laura Marchesini; Simonetta Mencherini; Mario Messina; Gerald Rogan Neba; Gloria Pelizzo; Simone Pizzi; Giovanna Riccipetitoni; Alessandro Simonini; Costanza Tognon; Mario Lima
Journal:  Surg Endosc       Date:  2022-09-19       Impact factor: 3.453

Review 2.  A review of simulation training and new 3D computer-generated synthetic organs for robotic surgery education.

Authors:  Daniel M Costello; Isabel Huntington; Grace Burke; Brooke Farrugia; Andrea J O'Connor; Anthony J Costello; Benjamin C Thomas; Philip Dundee; Ahmed Ghazi; Niall Corcoran
Journal:  J Robot Surg       Date:  2021-09-03

3.  Evaluation of skin cancer resection guide using hyper-realistic in-vitro phantom fabricated by 3D printing.

Authors:  Jongwoo Choi; Namkug Kim; Junhyeok Ock; Taehun Kim; Sangwook Lee; Tae Seong Yang; Minji Kim; Wooshik Jeong
Journal:  Sci Rep       Date:  2021-04-26       Impact factor: 4.379

4.  Adapting Urology Residency Training in the COVID-19 Era.

Authors:  Young Suk Kwon; Alexandra L Tabakin; Hiren V Patel; Jeffrey R Backstrand; Thomas L Jang; Isaac Y Kim; Eric A Singer
Journal:  Urology       Date:  2020-04-24       Impact factor: 2.649

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.