Deriving the 12-lead electrocardiogram from four (EASI) electrodes.

G E Dower1, A Yakush, S B Nazzal, R V Jutzy, C E Ruiz.   

Abstract

Computerized interpretation of the electrocardiogram has now advanced to computerization of the electrocardiograph, resulting in greatly increased versatility, including the capacity for adapting to a variety of lead systems rather than being tethered to the old Einthoven-Wilson-Goldberger (EWG) system. Many varieties of display beyond the 12-lead ECG are also available in software. To date, these new and interesting capabilities have scarcely been exploited. The EASI lead system uses the E, A, and I electrode positions of the Frank lead system, plus an electrode, S, positioned over the upper end of the sternum and, if necessary, ground (anywhere convenient). Its outputs form quasi-xyz signals, x'y'z', that can be approximately transformed into xyz signals by means of a matrix derived from the EASI lead vectors. The result forms a good basis for deriving the 12-lead ECG, using previously published coefficients for the Frank lead system. The match with the conventional ECG can then be improved by statistical means. The results are surprisingly good, and certainly of clinical value. Recent widespread interest in silent ischemia and its detection through Holter monitoring suggests an immediate application which has been rendered practical by the recent introduction of three-channel recorders. The EASI electrode positions give technically satisfactory Holter recordings. Very compact three-channel, multiplexed, radio telemetry equipment is now commercially available and provides another application for the EASI 12-lead ECG.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1988        PMID: 3216172     DOI: 10.1016/0022-0736(88)90090-8

Source DB:  PubMed          Journal:  J Electrocardiol        ISSN: 0022-0736            Impact factor:   1.438


  18 in total

1.  Assessment of the stability of the individual-based correction of QT interval for heart rate.

Authors:  Jean-Philippe Couderc; Xia Xiaojuan; Wojciech Zareba; Arthur J Moss
Journal:  Ann Noninvasive Electrocardiol       Date:  2005-01       Impact factor: 1.468

Review 2.  Technical mistakes during the acquisition of the electrocardiogram.

Authors:  Javier García-Niebla; Pablo Llontop-García; Juan Ignacio Valle-Racero; Guillem Serra-Autonell; Velislav N Batchvarov; Antonio Bayés de Luna
Journal:  Ann Noninvasive Electrocardiol       Date:  2009-10       Impact factor: 1.468

3.  A wearable wireless ECG monitoring system with dynamic transmission power control for long-term homecare.

Authors:  Yishan Wang; Sammy Doleschel; Ralf Wunderlich; Stefan Heinen
Journal:  J Med Syst       Date:  2015-02-15       Impact factor: 4.460

Review 4.  Cardiac Monitoring in the Emergency Department.

Authors:  Jessica K Zègre-Hemsey; J Lee Garvey; Mary G Carey
Journal:  Crit Care Nurs Clin North Am       Date:  2016-07-02       Impact factor: 1.326

5.  Rotors exhibit greater surface ECG variation during ventricular fibrillation than focal sources due to wavebreak, secondary rotors, and meander.

Authors:  Gordon Ho; Christopher T Villongco; Omid Yousefian; Aaron Bradshaw; Andrew Nguyen; Yonatan Faiwiszewski; Justin Hayase; Wouter-Jan Rappel; Andrew D McCulloch; David E Krummen
Journal:  J Cardiovasc Electrophysiol       Date:  2017-08-04

6.  Classification of COVID-19 electrocardiograms by using hexaxial feature mapping and deep learning.

Authors:  Mehmet Akif Ozdemir; Gizem Dilara Ozdemir; Onan Guren
Journal:  BMC Med Inform Decis Mak       Date:  2021-05-25       Impact factor: 2.796

7.  Spatiotemporal representation of cardiac vectorcardiogram (VCG) signals.

Authors:  Hui Yang; Satish Ts Bukkapatnam; Ranga Komanduri
Journal:  Biomed Eng Online       Date:  2012-03-30       Impact factor: 2.819

8.  Selection of optimal recording sites for limited lead body surface potential mapping: a sequential selection based approach.

Authors:  Dewar D Finlay; Chris D Nugent; Mark P Donnelly; Robert L Lux; Paul J McCullagh; Norman D Black
Journal:  BMC Med Inform Decis Mak       Date:  2006-02-17       Impact factor: 2.796

9.  Long-term ST database: a reference for the development and evaluation of automated ischaemia detectors and for the study of the dynamics of myocardial ischaemia.

Authors:  F Jager; A Taddei; G B Moody; M Emdin; G Antolic; R Dorn; A Smrdel; C Marchesi; R G Mark
Journal:  Med Biol Eng Comput       Date:  2003-03       Impact factor: 3.079

Review 10.  [Detection of ECG alterations typical for myocardial ischemia : New methods 2021].

Authors:  Sascha Beck; Valeria Martínez Pereyra; Andreas Seitz; Raffi Bekeredjian; Udo Sechtem; Peter Ong
Journal:  Internist (Berl)       Date:  2021-05-26       Impact factor: 0.743

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.