Literature DB >> 25682358

A wearable wireless ECG monitoring system with dynamic transmission power control for long-term homecare.

Yishan Wang1, Sammy Doleschel, Ralf Wunderlich, Stefan Heinen.   

Abstract

This paper presents a wearable wireless ECG monitoring system based on novel 3-Lead electrode placements for long-term homecare. The experiment for novel 3-Lead electrode placements is carried out, and the results show that the distance between limb electrodes can be significantly reduced. Based on the new electrode position, a small size sensor node, which is powered by a rechargeable battery, is designed to detect, amplify, filter and transmit the ECG signals. The coordinator receives the data and sends it to PC. Finally the signals are displayed on the GUI. In order to control the power consumption of sensor node, a dynamic power adjustment method is applied to automatically adjust the transmission power of the sensor node according to the received signal strength indicator (RSSI), which is related to the distance and obstacle between sensor node and coordinator. The system is evaluated when the user, who wears the sensor, is walking and running. A promising performance is achieved even under body motion. The power consumption can be significantly reduced with this dynamic power adjustment method.

Mesh:

Year:  2015        PMID: 25682358     DOI: 10.1007/s10916-015-0223-5

Source DB:  PubMed          Journal:  J Med Syst        ISSN: 0148-5598            Impact factor:   4.460


  13 in total

Review 1.  On selecting a body surface mapping procedure.

Authors:  R Hoekema; G J Uijen; A van Oosterom
Journal:  J Electrocardiol       Date:  1999-04       Impact factor: 1.438

2.  Development of a portable Linux-based ECG measurement and monitoring system.

Authors:  Tan-Hsu Tan; Ching-Su Chang; Yung-Fa Huang; Yung-Fu Chen; Cheng Lee
Journal:  J Med Syst       Date:  2009-11-14       Impact factor: 4.460

3.  Towards improved healthcare performance: examining technological possibilities and patient satisfaction with wireless body area networks.

Authors:  Rune Fensli; Jan Gunnar Dale; Philip O'Reilly; John O'Donoghue; David Sammon; Torstein Gundersen
Journal:  J Med Syst       Date:  2009-05-12       Impact factor: 4.460

4.  A WBAN-based real-time electroencephalogram monitoring system: design and implementation.

Authors:  Haifeng Chen; Wanqing Wu; Jungtae Lee
Journal:  J Med Syst       Date:  2010-06       Impact factor: 4.460

5.  SHIMMER: an extensible platform for physiological signal capture.

Authors:  Adrian Burns; Emer P Doheny; Barry R Greene; Timothy Foran; Daniel Leahy; Karol O'Donovan; Michael J McGrath
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2010

6.  Design and tests of a smartphones-based multi-lead ECG monitoring system.

Authors:  Hongqiao Gao; Xiaohui Duan; Xiaoqiang Guo; Anpeng Huang; Bingli Jiao
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2013

7.  Link-state-estimation-based transmission power control in wireless body area networks.

Authors:  Seungku Kim; Doo-Seop Eom
Journal:  IEEE J Biomed Health Inform       Date:  2013-09-20       Impact factor: 5.772

8.  Deriving the 12-lead electrocardiogram from four (EASI) electrodes.

Authors:  G E Dower; A Yakush; S B Nazzal; R V Jutzy; C E Ruiz
Journal:  J Electrocardiol       Date:  1988       Impact factor: 1.438

9.  A real-time QRS detection algorithm.

Authors:  J Pan; W J Tompkins
Journal:  IEEE Trans Biomed Eng       Date:  1985-03       Impact factor: 4.538

10.  A new system of multiple-lead exercise electrocardiography.

Authors:  R E Mason; I Likar
Journal:  Am Heart J       Date:  1966-02       Impact factor: 4.749

View more
  7 in total

1.  A Study on the Optimal Positions of ECG Electrodes in a Garment for the Design of ECG-Monitoring Clothing for Male.

Authors:  Hakyung Cho; Joo Hyeon Lee
Journal:  J Med Syst       Date:  2015-08-08       Impact factor: 4.460

2.  Evaluation of Digital Compressed Sensing for Real-Time Wireless ECG System with Bluetooth low Energy.

Authors:  Yishan Wang; Sammy Doleschel; Ralf Wunderlich; Stefan Heinen
Journal:  J Med Syst       Date:  2016-05-30       Impact factor: 4.460

3.  Cooperative wireless network control based health and activity monitoring system.

Authors:  R Prakash; A Balaji Ganesh; Siva V Girish
Journal:  J Med Syst       Date:  2016-08-25       Impact factor: 4.460

Review 4.  An Engineering Perspective of External Cardiac Loop Recorder: A Systematic Review.

Authors:  Avvaru Srinivasulu; N Sriraam
Journal:  J Med Eng       Date:  2016-10-31

5.  A Personalized Arrhythmia Monitoring Platform.

Authors:  Sandeep Raj; Kailash Chandra Ray
Journal:  Sci Rep       Date:  2018-07-30       Impact factor: 4.379

6.  Wearable Wireless Body Area Networks for Medical Applications.

Authors:  Carlos A Tavera; Jesús H Ortiz; Osamah I Khalaf; Diego F Saavedra; Theyazn H H Aldhyani
Journal:  Comput Math Methods Med       Date:  2021-04-24       Impact factor: 2.238

Review 7.  ECG Monitoring Systems: Review, Architecture, Processes, and Key Challenges.

Authors:  Mohamed Adel Serhani; Hadeel T El Kassabi; Heba Ismail; Alramzana Nujum Navaz
Journal:  Sensors (Basel)       Date:  2020-03-24       Impact factor: 3.576

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.