Literature DB >> 32141646

Spin-lock relaxation rate dispersion reveals spatiotemporal changes associated with tubulointerstitial fibrosis in murine kidney.

Feng Wang1,2, Daniel C Colvin1, Suwan Wang3, Hua Li1, Zhongliang Zu1,2, Raymond C Harris3, Ming-Zhi Zhang3, John C Gore1,2,4.   

Abstract

PURPOSE: To develop and evaluate a reliable non-invasive means for assessing the severity and progression of fibrosis in kidneys. We used spin-lock MR imaging with different locking fields to detect and characterize progressive renal fibrosis in an hHB-EGFTg/Tg mouse model.
METHODS: Male hHB-EGFTg/Tg mice, a well-established model of progressive fibrosis, and age-matched normal wild type (WT) mice, were imaged at 7T at ages 5-7, 11-13, and 30-40 weeks. Spin-lock relaxation rates R1 ρ were measured at different locking fields (frequencies) and the resultant dispersion curves were fit to a model of exchanging water pools. The obtained MRI parameters were evaluated as potential indicators of tubulointerstitial fibrosis in kidney. Histological examinations of renal fibrosis were also carried out post-mortem after MRI.
RESULTS: Histology detected extensive fibrosis in the hHB-EGFTg/Tg mice, in which collagen deposition and reductions in capillary density were observed in the fibrotic regions of kidneys. R2 and R1 ρ values at different spin-lock powers clearly dropped in the fibrotic region as fibrosis progressed. There was less variation in the asymptotic locking field relaxation rate R 1 ρ ∞ between the groups. The exchange parameter Sρ and the inflection frequency ωinfl changed by larger factors.
CONCLUSION: Both Sρ and ωinfl depend primarily on the average exchange rate between water and other chemically shifted resonances such as hydroxyls and amides. Spin-lock relaxation rate dispersion, rather than single measurements of relaxation rates, provides more comprehensive and specific information on spatiotemporal changes associated with tubulointerstitial fibrosis in murine kidney.
© 2020 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  zzm321990Rzzm3219901zzm321990zzm321990ρzzm321990zzm321990; MRI; dispersion; mouse kidney disease; relaxation; renal fibrosis; spin-lock

Mesh:

Substances:

Year:  2020        PMID: 32141646      PMCID: PMC7329575          DOI: 10.1002/mrm.28230

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  40 in total

Review 1.  Fibrosis--a common pathway to organ injury and failure.

Authors:  Don C Rockey; P Darwin Bell; Joseph A Hill
Journal:  N Engl J Med       Date:  2015-03-19       Impact factor: 91.245

Review 2.  Current MRI techniques for the assessment of renal disease.

Authors:  Takamune Takahashi; Feng Wang; Christopher C Quarles
Journal:  Curr Opin Nephrol Hypertens       Date:  2015-05       Impact factor: 2.894

Review 3.  Obstructive nephropathy: towards biomarker discovery and gene therapy.

Authors:  Robert L Chevalier
Journal:  Nat Clin Pract Nephrol       Date:  2006-03

4.  Determinants of proton relaxation rates in tissue.

Authors:  S H Koenig; R D Brown
Journal:  Magn Reson Med       Date:  1984-12       Impact factor: 4.668

5.  Quantitative studies of hydrodynamic effects and cross-relaxation in protein solutions and tissues with proton and deuteron longitudinal relaxation times.

Authors:  J H Zhong; J C Gore; I M Armitage
Journal:  Magn Reson Med       Date:  1990-02       Impact factor: 4.668

6.  Magnetic resonance elastography noninvasively detects in vivo renal medullary fibrosis secondary to swine renal artery stenosis.

Authors:  Michael J Korsmo; Behzad Ebrahimi; Alfonso Eirin; John R Woollard; James D Krier; John A Crane; Lizette Warner; Kevin Glaser; Roger Grimm; Richard L Ehman; Lilach O Lerman
Journal:  Invest Radiol       Date:  2013-02       Impact factor: 6.016

Review 7.  How bold is blood oxygenation level-dependent (BOLD) magnetic resonance imaging of the kidney? Opportunities, challenges and future directions.

Authors:  T Niendorf; A Pohlmann; K Arakelyan; B Flemming; K Cantow; J Hentschel; D Grosenick; M Ladwig; H Reimann; S Klix; S Waiczies; E Seeliger
Journal:  Acta Physiol (Oxf)       Date:  2014-09-30       Impact factor: 6.311

8.  Contributions of chemical and diffusive exchange to T1ρ dispersion.

Authors:  Jared Guthrie Cobb; Jingping Xie; John C Gore
Journal:  Magn Reson Med       Date:  2012-07-12       Impact factor: 4.668

9.  New Magnetic Resonance Imaging Index for Renal Fibrosis Assessment: A Comparison between Diffusion-Weighted Imaging and T1 Mapping with Histological Validation.

Authors:  I Friedli; L A Crowe; L Berchtold; S Moll; K Hadaya; T de Perrot; C Vesin; P-Y Martin; S de Seigneux; J-P Vallée
Journal:  Sci Rep       Date:  2016-07-21       Impact factor: 4.379

10.  Assessment of renal function in mice with unilateral ureteral obstruction using 99mTc-MAG3 dynamic scintigraphy.

Authors:  Mohammed N Tantawy; Rosie Jiang; Feng Wang; Keiko Takahashi; Todd E Peterson; Dana Zemel; Chuan-Ming Hao; Hiroki Fujita; Raymond C Harris; Christopher C Quarles; Takamune Takahashi
Journal:  BMC Nephrol       Date:  2012-12-10       Impact factor: 2.388

View more
  2 in total

1.  Is MRI relaxometry parameter T specific to fibrosis or confounded by concomitant pathological features?

Authors:  Stefanie J Hectors
Journal:  Quant Imaging Med Surg       Date:  2020-12

Review 2.  Clinical and experimental approaches for imaging of acute kidney injury.

Authors:  Daisuke Katagiri; Feng Wang; John C Gore; Raymond C Harris; Takamune Takahashi
Journal:  Clin Exp Nephrol       Date:  2021-04-09       Impact factor: 2.801

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.