Sigfus Thor Eliasson1,2, Jon Einar Dahl1.
Abstract
Objectives: To investigate temperature changes in various test specimens during thermal cycling and to evaluate difference in micro-tensile repair bond strength in specimens cut from the inner or the outer area of composite blocks after thermal cycling. Materials and methods: Four rectangular composite blocks of various sizes were fabricated, and thermocouples placed in the centre of the specimens or halfway from the surface to the centre. Composite cylinders were made on ground flat extracted molars, as intended for micro-tensile and shear bond testing, with a thermocouple placed at the centre of the cylinder radius between composite and dentin. The specimens were thermal cycled between 5 °C and 55 °C with 20-60 s dwell times. The highest and lowest temperatures in the test specimens were recorded. Composite blocks were fabricated and stored in water for a week and then repaired with the same composite. After thermal cycling (5000×, 5 °C and 55 °C with a 20 s dwell time), test specimens were cut for micro-tensile testing.Entities:
Keywords: Ageing; composite; dwell time; micro-tensile strength testing; shear strength testing; thermal gradient
Year: 2020 PMID: 32128509 PMCID: PMC7033714 DOI: 10.1080/26415275.2019.1709470
Source DB: PubMed Journal: Biomater Investig Dent ISSN: 2641-5275
Materials used in the investigation.
| Product | Manufacturer | Lot no. | Expiry date |
|---|---|---|---|
| Filtek™ Supreme XTE Universal Restorative A2B | 3MEspe Dental Products, | N941996 | 2020-08 |
| Scotchbond Universal Adhesive | 3MEspe Dental Products, | 70831A | 2019-07 |
| Permadyne™Garant 2:1 Light bodied Consistency | 3MEspe Dental Products | 3804066 | 2019-07 |
Figure 1.Various sized composite blocks, test specimens named a, b, c, and d with thermocouples placed in the centre or half-way from surface to centre.
Figure 2.Test specimen assemblies named e, f, and g, with thermocouples placed in the centre radius between tooth and composite.
Figure 3.Overview of composite block cut in the x and y directions, with rod ends color-coded for identification of position and used for micro-tensile testing.
Repair micro-tensile bond strength of test specimens stored in water for 3 months and tested after thermal cycling and without thermal cycling.
| 3 months in water + thermal cycling | 3 months in water (control) | ||
|---|---|---|---|
| outer specimens | inner specimens | outer specimens | inner specimens |
| 37.8 ± 8.8 MPaA,B,C | 55.5 ± 8.5 MPaA | 58.3 ± 4.2 MPaB | 59.1 ± 6.4 MPaC |
Groups with same upper-case letters are statistically significant different (p < .05).
Temperature measured in resin based composite test specimens in 5 °C water bath at different dwell times (n = 25).
| Specimen designation | ||||
|---|---|---|---|---|
| Specimen size | a | b | c | d |
| Thermocouple | Centre | Centre | Centre | 2.5 mm from surface |
| Dwell time (s) | ||||
| 20 | 7.8 ± 0.11 °C | 14.3 ± 0.25 °C | 17.7 ± 0.22 °C | 12.3 ± 0.65 °C |
| 30 | 5.6 ± 0.06 °C | 9.2 ± 0.09 °C | 12.1 ± 0.13 °C | 8.7 ± 0.19 °C |
| 40 | 5.2 ± 0.11 °C | 6.3 ± 0.15 °C | 8.0 ± 0.18 °C | 6.6 ± 0.16 °C |
| 50 | 5.0 ± 0.05 °C | 5.7 ± 0.16 °C | 6.8 ± 0.11 °C | 6.1 ± 0.13 °C |
| 60 | 5.0 ± 0.06 °C | 5.3 ± 0.15 °C | 5.7 ± 0.07 °C | 5.4 ± 0.16 °C |
Temperature measured in resin based composite test specimens in 55 °C water bath at different dwell times (n = 25).
| Specimen designation | ||||
|---|---|---|---|---|
| Specimen size | a | b | c | d |
| Thermocouple | Centre | Centre | Centre | 2.5 mm from surface |
| Dwell time (s) | ||||
| 20 | 52.2 ± 0.14 °C | 45.2 ± 0.37 °C | 42.4 ± 0.44 °C | 48.0 ± 1.01 °C |
| 30 | 54.3 ± 0.08 °C | 50.4 ± 0.20 °C | 48.0 ± 0.14 °C | 51.4 ± 0.10 °C |
| 40 | 55.2 ± 0.02 °C | 53.0 ± 0.63 °C | 51.1 ± 0.23 °C | 53.4 ± 0.14 °C |
| 50 | 55.2 ± 0.11 °C | 54.4 ± 0.17 °C | 53.1 ± 0.32 °C | 55.2 ± 0.14 °C |
| 60 | 55.2 ± 0.14 °C | 55.0 ± 0.07 °C | 54.2 ± 0.10 °C | 55.1 ± 0.17 °C |
Temperature measured in the centre of specimens at the adhesive layer in 5 °C water bath at different dwell times (n = 25).
| Specimen designation | |||
|---|---|---|---|
| e | f | g | |
| Specimen size | 10 mm Ø×10 mm composite cylinder on tooth | 10 mm Ø×10 mm composite cylinder on tooth, mounted in resin | 2.38 mm Ø×4 mm composite cylinder on tooth, mounted in resin |
| Dwell time (s) | |||
| 20 | 17.6 ± 0.35 °C | 22.4 ± 1.40 °C | 7.6 ± 0.13 °C |
| 30 | 13.0 ± 0.15 °C | 18.5 ± 0.19 °C | 7.0 ± 0.08 °C |
| 40 | 8.7 ± 0.31 °C | 16.0 ± 0.56 °C | 6.2 ± 0.15 °C |
| 50 | 7.4 ± 0.27 °C | 14.3 ± 0.25 °C | 6.1 ± 0.19 °C |
| 60 | 6.3 ± 0.09 °C | 12.9 ± 0.17 °C | 6.0 ± 0.14 °C |
Temperature measured in the centre of specimens at the adhesive layer in 55 °C water bath at different dwell times (n = 25).
| Specimen designation | |||
|---|---|---|---|
| e | f | g | |
| Specimen size | 10 mm Ø×10 mm composite cylinder on tooth | 10 mm Ø×10 mm composite cylinder on tooth, mounted in resin | 2.38 mm Ø×4 mm composite cylinder on tooth, mounted in resin |
| Dwell time (s) | |||
| 20 | 42.2 ± 0.45 °C | 37.8 ± 1.00 °C | 53.2 ± 0.15 °C |
| 30 | 46.9 ± 0.20 °C | 41.6 ± 0.17 °C | 53.9 ± 0.14 °C |
| 40 | 50.2 ± 0.16 °C | 43.7 ± 0.66 °C | 54.2 ± 0.28 °C |
| 50 | 52.4 ± 0.30 °C | 45.8 ± 0.19 °C | 54.4 ± 0.20 °C |
| 60 | 53.8 ± 0.22 °C | 46.9 ± 0.12 °C | 54.7 ± 0.15 °C |