| Literature DB >> 32115636 |
Michał Biegała1,2, Teresa Jakubowska2,3.
Abstract
This paper aims to determine the levels of exposure to neutron and photon radiation among the personnel engaged in cyclotron operation and the personnel engaged in the production of radiopharmaceuticals, with the use of the environmental radiation monitoring system (RMS) installed in the positron emission tomography laboratory. The annual exposures of employees operating the cyclotron measured with the use of the RMS system are: 1.39 ± 0.16 mSv in case of photon radiation and 2.61 ± 0.14 mSv in case of neutron radiation. In the case of employees in the radiopharmaceuticals' production zone, the annual exposures measured by means of the RMS system are 0.15 ± 0.03 mSv in case of photon radiation and 0.11 ± 0.01 mSv in case of neutron radiation. The exposure levels among the personnel engaged in cyclotron operation and the personnel engaged in the production of radiopharmaceuticals are below the permissible radiation dose limits.Entities:
Mesh:
Substances:
Year: 2020 PMID: 32115636 PMCID: PMC7703741 DOI: 10.1093/rpd/ncaa012
Source DB: PubMed Journal: Radiat Prot Dosimetry ISSN: 0144-8420 Impact factor: 0.972
Figure 1diagram of distribution of measuring points (A—cyclotron bunker, B—cyclotron control room, C—radiopharmaceutical production room, D—cyclotron zone corridor, N—neutron detectors, G—gamma detectors) and the location of the Eclipse HP cyclotron in the bunker along with the position of the beam outputs (TG1 and TG2).
Average dose rates obtained at individual measuring points.
| Channel—isotope | TG1—18F | TG2—18F | TG1—11C |
|---|---|---|---|
| Detectors | Average dose ± SD [μSv per h] | Average dose ± SD [μSv per h] | Average dose ± SD [μSv per h] |
| G1 | 25.98 ± 2.85 | 66.13 ± 4.34 | 7.48 ± 1.75 |
| N1 | 54.59 ± 3.84 | 236.56 ± 8.48 | 15.29 ± 3.18 |
| G2 | 1.77 ± 0.28 | 4.71 ± 0.61 | 0.65 ± 0.15 |
| N2 | 1.16 ± 0.09 | 5.27 ± 0.21 | 0.31 ± 0.07 |
| G3 | 0.40 ± 0.08 | 0.67 ± 0.13 | 0.23 ± 0.06 |
| N3 | 0.14 ± 0.02 | 0.71 ± 0.04 | 0.04 ± 0.02 |
| G4 | 0.31 ± 0.06 | 0.68 ± 0.09 | 0.16 ± 0.03 |
| N4 | 0.80 ± 0.12 | 2.76 ± 0.33 | 0.20 ± 0.05 |
Annual radiation doses calculated at appropriate measurement points.
| Type of dosemeter | Dose per year [mSv] | Total dose per year [mSv] (G + N) | Factor |
|---|---|---|---|
| G1 | 11.86 ± 0.99 | 48.70 ± 0.44 | 3.11 ± 0.03 |
| N1 | 36.84 ± 1.69 | ||
| G2 | 0.84 ± 0.02 | 1.65 ± 0.02 | 0.97 ± 0.01 |
| N2 | 0.81 ± 0.03 | ||
| G3 | 0.15 ± 0.03 | 0.25 ± 0.01 | 0.74 ± 0.02 |
| N3 | 0.11 ± 0.01 | ||
| G4 | 0.12 ± 0.01 | 0.54 ± 0.02 | 3.34 ± 0.05 |
| N4 | 0.41 ± 0.06 |
Radiation doses in the cyclotron operating zone and in the radiopharmaceutical production room.
| Type of dosemeter | Measuring points | Dose per year [mSv] | Total dose per year [mSv] (G + N) | Factor | |
|---|---|---|---|---|---|
| Gamma (G) | Neutrons (N) | ||||
| RMS | G1, N1 + G2, N2 | 1.39 ± 0.16 | 2.61 ± 0.14 | 4.00 ± 0.06 | 1.88 ± 0.03 |
| RMS + FH 40 G-10 | G1, N1 + G4, N4 | 0.71 ± 0.04 | 2.24 ± 0.11 | 2.95 ± 0.02 | 3.14 ± 0.02 |
| RMS | G3, N3 | 0.15 ± 0.03 | 0.11 ± 0.01 | 0.26 ± 0.01 | 0.74 ± 0.01 |