Xin Li1, Xinwen Min1.
Abstract
Epicardial movement during diastole is inversely proportional to myocardial stiffness but systolic regional thickening cannot precisely identify ischemic territories. The aim of the present study was to test the hypothesis that a correlation may be present between M-mode echocardiography parameters and poor outcomes in patients with heart failure and preserved ejection fraction. Patients with known cardiovascular disease were included in the test group (n=1,244) and patients without known cardiovascular disease were included in the control group (n=1,952). Patient records of routine measurements, M-mode echocardiography and mortality were collected. The control population and test population had the same left ventricular end-diastolic dimension (P=0.062) and left ventricular end-diastolic volume (P=0.053). A lower mitral flow velocity (P<0.05), higher Tei index (P<0.0001) and reduced distribution of diastolic wall strain (P<0.0001) were reported in the test populations compared with the control population. Patients of the test population with lower diastolic wall strain (<0.28) demonstrated a higher mortality rate than those with higher diastolic wall strain (≥0.28; P<0.0001) at the 3-year follow-up. M-mode echocardiographic parameters may be of use for predicting poor outcomes in patients with heart failure and preserved ejection fraction.Entities:
Keywords: M-mode echocardiography; diastolic wall strain; ejection fraction; heart failure; mitral flow velocity
Year: 2020 PMID: 32104256 PMCID: PMC7027013 DOI: 10.3892/etm.2020.8428
Source DB: PubMed Journal: Exp Ther Med ISSN: 1792-0981 Impact factor: 2.447