Literature DB >> 32101501

Fracture Resistance and Failure Mode of Custom-made Post-and-cores of Polyetheretherketone and Nano-ceramic Composite.

K N Teixeira, T M Duque, H P Maia, Tmsv Gonçalves.   

Abstract

CLINICAL RELEVANCE: Custom-made post-and-cores of polyetheretherketone (PEEK) and nano-ceramic composite showed good fracture resistance and failure mode. Clinicians should be aware that these materials might be an efficient alternative for post-and-cores, because they promote esthetics while reducing the risk of root fractures.
SUMMARY: Purpose: The purpose of this study was to evaluate the fracture resistance and failure mode of custom-made post-and-cores manufactured with different esthetic materials.Methods and Materials: A total of 48 mandibular premolar extracted teeth were selected, endodontically treated, and prepared to receive the posts. Specimens were randomly divided into four groups (n=12/group): group 1, polyetheretherketone (PEEK, Degos; G1); group 2, nano-ceramic composite (Lava Ultimate, 3M ESPE; G2); group 3, cast metal post (NiCr alloy, control; G3); group 4, fiberglass post (Whitepost, FGM, control; G4) customized with a nano-hybrid resin composite (Z250, 3M ESPE). Experimental post-and-cores (G1 and G2) were manufactured with a computer-aided design/computer-aided manufacturing system. All posts were cemented with self-adhesive resin cement (Rely X U200, 3M ESPE), and specimens were stored in distilled water at 37°C for 60 days. A universal testing machine was used to measure the fracture resistance (0.5 mm/min at an angle of 45° to the long axis of the tooth). Fractures were classified as repairable or catastrophic. One-way analysis of variance with Tukey post hoc and χ2 tests for independence and Bonferroni adjustments were applied (α=0.05).
Results: The fracture resistance values (mean ± SD, in newtons) were 379.4 ± 119.8 (G1), 506.4 ± 138 (G2), 939.6 ± 146.5 (G3), and 449.6 ± 66.5 (G4). Only G3 exhibited a significant difference (p<0.05). The χ2 test showed an association between failure mode and post-and-core material [χ2(3) = 23.65; p<0.001]. After Bonferroni adjustment, only G3 presented a higher than expected incidence of catastrophic failures (p<0.001). In the remaining groups, most failures were repairable and related to debonding.Conclusions: Customized post-and-cores of PEEK and nano-ceramic composites exhibited good mechanical performance. Their fracture resistance was comparable to that observed for fiberglass customized posts, yet lower than that for cast metal posts. For PEEK post-and-cores, in particular, additional studies are needed to improve adhesiveness and reduce the risk of debonding. © Operative Dentistry, 2020.

Entities:  

Mesh:

Substances:

Year:  2020        PMID: 32101501     DOI: 10.2341/19-080-L

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  2 in total

1.  PEEK and fiberglass intra-radicular posts: influence of resin cement and mechanical cycling on push-out bond strength.

Authors:  Lara Christie Monteiro; Vanessa Gallego Arias Pecorari; Isabela Guerra Gontijo; Giselle Maria Marchi; Débora Alves Nunes Leite Lima; Flávio Henrique Baggio Aguiar
Journal:  Clin Oral Investig       Date:  2022-07-26       Impact factor: 3.606

Review 2.  PEEK in Fixed Dental Prostheses: Application and Adhesion Improvement.

Authors:  Biyao Wang; Minghao Huang; Pengrui Dang; Jiahui Xie; Xinwen Zhang; Xu Yan
Journal:  Polymers (Basel)       Date:  2022-06-08       Impact factor: 4.967

  2 in total