| Literature DB >> 32095555 |
Michal Stankiewicz1,2, Winnie Li1,2, Tara Rosewall1,2, Tony Tadic1,2, Colleen Dickie1,2, Michael Velec1,2,3.
Abstract
PURPOSE: Substantial, unanticipated anatomic variances during cone-beam CT (CBCT)-guided radiotherapy can potentially impact treatment accuracy and clinical outcomes. This study assessed patterns of practice of CBCT variances reported by RTTs and subsequent interventions for multiple-disease sites.Entities:
Keywords: Adaptive radiation therapy; Cone-beam CT; Image registration; Inter-fraction motion
Year: 2019 PMID: 32095555 PMCID: PMC7033808 DOI: 10.1016/j.tipsro.2019.10.003
Source DB: PubMed Journal: Tech Innov Patient Support Radiat Oncol ISSN: 2405-6324
Categories of IGRT-related variances reported by RTTs.
| Main Category | Sub-Category | Description |
|---|---|---|
| Tumor-related | Tumor motion | Target displacement, motion or deformation with stable volume |
| Tumor regression | Suspected decrease in target volume | |
| Tumor progression | Suspected increase in target volume | |
| Non tumor-related | Normal tissue motion | Normal tissue displacement, motion or deformation |
| Large shift/rotation | A translation/rotation exceeding the maximum action level | |
| Bone mismatch | Bony anatomy deformation or rotation | |
| Bladder/rectum filling | Increase or decrease in bladder/rectum volume | |
| Weight gain | Overall expansion of external body contour | |
| Weight loss | Overall decrease of external body contour | |
| Local swelling | Localized expansion of external body contour | |
| Abdominal gas | Substantial increase in gas (excluding rectum) | |
| Fluids | Increase of fluid in lungs or sinuses | |
Supplementary Table S1Cases of IGRT-related variances over 1-year and their outcomes following offline multi-disciplinary assessment.
| Intervention | Variances reported by RTTs | Additional variances identified | Total ( | |
|---|---|---|---|---|
| Continue treatment | 207 | 0 | 207 | |
| Repeat CT-sim only, then continue treatment | 17 | 4 | 21 | |
| Re-plan using original CT-sim | 2 | 1 | 3 | |
| Repeat CT-sim and re-plan | 46 | 10 | 56 | |
Notes:
Reported by unit e-mail.
Identified in the treatment planning and record-and-verify systems.
Treatment later discontinued in 9 cases.
Treatment later discontinued in 1 case.
Fig. 1Relative timing of IGRT-related variances reported by RTTs during the treatment course including all dose/fraction schedules.
Supplementary Fig. S1
Fig. 2Distribution by disease site for all IGRT-related variances identified (left) and those subsequently re-planned (right).
Fig. 3Frequency of RTT-reported variances by category of findings on CBCT.
Fig. 4Re-planning outcomes (left) and timing (right) of IGRT-related variances by category.