Literature DB >> 32087129

Lateral flow assay using aptamer-based sensing for on-site detection of dopamine in urine.

Shima Dalirirad1, Andrew J Steckl2.   

Abstract

A lateral flow assay using DNA aptamer-based sensing for the detection of dopamine in urine is reported. Dopamine duplex aptamers (hybridized sensor with capture probe) are conjugated to 40-nm Au nanoparticles (AuNPs) with 20T linkers. The detection method is based on the dissociation of the duplex aptamer in the presence of dopamine, with the sensor part undergoing conformational changes and being released from the capture part. Hybridization between the complementary DNA in the test line and the conjugated AuNP-capture DNA produces a red band, whose intensity is related to the dopamine concentration. The minimum detectable concentration obtained by ImageJ analysis was <10 ng/mL (65.2 nM), while the visual limit of detection is estimated to be ~50 ng/mL (normal range of dopamine in urine of 52-480 ng/mL or 0.3-3.13 μM). No cross reactivity to other stress biomarkers in urine was confirmed. These results indicate that this robust and user-friendly point-of-care biosensor has significant potential for providing a cost-effective alternative for dopamine detection in urine.
Copyright © 2020. Published by Elsevier Inc.

Entities:  

Keywords:  Aptamer; Au nanoparticle; Dopamine; Duplex dissociation; Lateral flow assay; Urine

Mesh:

Substances:

Year:  2020        PMID: 32087129     DOI: 10.1016/j.ab.2020.113637

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  11 in total

1.  Microporous carbon in the selective electro-oxidation of molecular biomarkers: uric acid, ascorbic acid, and dopamine.

Authors:  Tidapa Rattanaumpa; Santi Maensiri; Kamonwad Ngamchuea
Journal:  RSC Adv       Date:  2022-06-27       Impact factor: 4.036

Review 2.  Aptamer-based biosensors for virus protein detection.

Authors:  Beibei Lou; Yanfei Liu; Meilin Shi; Jun Chen; Ke Li; Yifu Tan; Liwei Chen; Yuwei Wu; Ting Wang; Xiaoqin Liu; Ting Jiang; Dongming Peng; Zhenbao Liu
Journal:  Trends Analyt Chem       Date:  2022-07-19       Impact factor: 14.908

Review 3.  Tutorial: design and fabrication of nanoparticle-based lateral-flow immunoassays.

Authors:  Claudio Parolo; Amadeo Sena-Torralba; José Francisco Bergua; Enric Calucho; Celia Fuentes-Chust; Liming Hu; Lourdes Rivas; Ruslan Álvarez-Diduk; Emily P Nguyen; Stefano Cinti; Daniel Quesada-González; Arben Merkoçi
Journal:  Nat Protoc       Date:  2020-10-23       Impact factor: 13.491

4.  β-Cyclodextrin functionalized 3D reduced graphene oxide composite-based electrochemical sensor for the sensitive detection of dopamine.

Authors:  Xuan Chen; Na Li; Yanqin Rong; Yuli Hou; Yu Huang; Wenting Liang
Journal:  RSC Adv       Date:  2021-08-19       Impact factor: 4.036

Review 5.  Monoclonal Antibodies Application in Lateral Flow Immunochromatographic Assays for Drugs of Abuse Detection.

Authors:  Zidane Qriouet; Yahia Cherrah; Hassan Sefrioui; Zineb Qmichou
Journal:  Molecules       Date:  2021-02-18       Impact factor: 4.411

6.  Aptamer-Based Lateral Flow Biosensor for Rapid Detection of Salivary Cortisol.

Authors:  Shima Dalirirad; Daewoo Han; Andrew J Steckl
Journal:  ACS Omega       Date:  2020-12-17

Review 7.  Development of nucleic acid aptamer-based lateral flow assays: A robust platform for cost-effective point-of-care diagnosis.

Authors:  Tao Wang; Lanmei Chen; Arpitha Chikkanna; Suxiang Chen; Isabell Brusius; Nabayet Sbuh; Rakesh N Veedu
Journal:  Theranostics       Date:  2021-03-05       Impact factor: 11.556

Review 8.  Aptamer-Based Biosensors for the Colorimetric Detection of Blood Biomarkers: Paving the Way to Clinical Laboratory Testing.

Authors:  Anna Davydova; Mariya Vorobyeva
Journal:  Biomedicines       Date:  2022-07-06

Review 9.  Point-of-Use Rapid Detection of SARS-CoV-2: Nanotechnology-Enabled Solutions for the COVID-19 Pandemic.

Authors:  Navid Rabiee; Mojtaba Bagherzadeh; Amir Ghasemi; Hossein Zare; Sepideh Ahmadi; Yousef Fatahi; Rassoul Dinarvand; Mohammad Rabiee; Seeram Ramakrishna; Mohammadreza Shokouhimehr; Rajender S Varma
Journal:  Int J Mol Sci       Date:  2020-07-20       Impact factor: 5.923

Review 10.  Aptamer-Based Lateral Flow Assays: Current Trends in Clinical Diagnostic Rapid Tests.

Authors:  Marjan Majdinasab; Mihaela Badea; Jean Louis Marty
Journal:  Pharmaceuticals (Basel)       Date:  2022-01-13
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.