Literature DB >> 32063423

Evaluation of interbreath-hold lung tumor position reproducibility with vector volume histogram using the breath-hold technique.

Hideharu Miura1, Shuichi Ozawa2, Minoru Nakao2, Yoshiko Doi2, Katsumaro Kubo3, Masahiko Kenjo2, Yasushi Nagata2.   

Abstract

Tumor geometric reproducibility for lung stereotactic body radiotherapy (SBRT) is an important issue in the breath-hold (BH) technique. We investigated the inter-BH reproducibility of the tumor position in expiratory BH using our proposed vector volume histogram (VVH) method. Subjects comprising 14 patients with lung cancer who were treated with lung SBRT under expiratory BH conditions were monitored by the Abches system. Multiple computed tomography (CT) scans were performed to evaluate the inter-BH reproducibility of the tumor position at the expiratory BH in the simulation session. Gross tumor volume was delineated by a physician. Deformable image registration was used to deform the images from the 3 expiratory BH-CTs to the treatment planning expiratory BH-CT. To evaluate the inter-BH reproducibility of the tumor positions, we measured the largest motion extent within the organ of 3 dimensions (left-right, LR; anterior-posterior, AP; cranio-caudal, CC) and a 3D vector using the VVH method. The average and standard deviations of the inter-BH reproducibility of the tumor position in the LR, AP, and CC directions, and the 3D vector were 1.7 ± 0.5, 2.0 ± 0.7, 2.1 ± 0.7, and 2.7 ± 0.7 mm, respectively. Ten patients exhibited inter-BH displacements of the lung tumor >3 mm in the 3D vector. No displacement >5 mm was observed in any direction for all patients. Our study indicated that the inter-BH variation of the tumor position was small for lung cancer patients, using the Abches system and the VVH method.
Copyright © 2020 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Abches system; Breath-hold; Interbreath-hold reproducibility; Lung; Respiratory management

Mesh:

Year:  2020        PMID: 32063423     DOI: 10.1016/j.meddos.2020.01.003

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  2 in total

1.  Determination of reproducibility of end-exhaled breath-holding in stereotactic body radiation therapy.

Authors:  Motoharu Sasaki; Hitoshi Ikushima; Kanako Sakuragawa; Michihiro Yokoishi; Akira Tsuzuki; Wataru Sugimoto
Journal:  J Radiat Res       Date:  2020-11-16       Impact factor: 2.724

2.  Impact on liver position under breath-hold by computed tomography contrast agents in stereotactic body radiotherapy of liver cancer.

Authors:  Hideharu Miura; Shuichi Ozawa; Minoru Nakao; Yoshiko Doi; Katsumaro Kubo; Masahiro Kenjo; Yasushi Nagata
Journal:  Rep Pract Oncol Radiother       Date:  2021-12-30
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.