Literature DB >> 32060989

1 H-guided reconstruction of 19 F gas MRI in COPD patients.

Arnd Jonathan Obert1,2, Marcel Gutberlet1,2, Agilo Luitger Kern1,2, Till Frederik Kaireit1,2, Robert Grimm3, Frank Wacker1,2, Jens Vogel-Claussen1,2.   

Abstract

PURPOSE: To reduce acquisition time and improve image quality and robustness of ventilation assessment in a single breath-hold using 1 H-guided reconstruction of fluorinated gas (19 F) MRI.
METHODS: Reconstructions constraining total variation in the image domain, L1 norm in the wavelet domain, and directional total variation between 19 F and 1 H images were compared in order to accelerate 19 F ventilation imaging using retrospectively undersampled data from a healthy volunteer. Using the optimal constrained reconstruction in 8 patients with chronic obstructive pulmonary disease (16-seconds breath-hold), ventilation maps of various acceleration factors (2-fold to 13-fold) were compared with maps of the full data set using the Dice coefficient, difference in volume defect percentage and overlap percentage, as well as hyperpolarized 129 Xe gas MRI.
RESULTS: The reconstruction constraining total variation and directional total variation simultaneously performed best in the healthy volunteer (RMS error = 0.07, structural similarity index = 0.77) for a measurement time of 2 seconds. Using the same reconstruction in the patients with chronic obstructive pulmonary disease, the Dice coefficient of defect volumes was 0.86 ± 0.05, the mean difference in volume defect percentage was -1.0 ± 1.7 percentage points, and the overlap percentage was 87% ± 2% for a measurement time of 6 seconds. Between volume defect percentage of 19 F and 129 Xe, a linear correlation (r = 0.75; P = .03) was found, with 19 F volume defect percentage being significantly higher (mean difference = 11%; P = .04).
CONCLUSION: 1 H-guided reconstruction of pulmonary 19 F gas MRI enables reduction of acquisition time while maintaining image quality and robustness of functional parameters.
© 2020 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  19F; 1H-guided reconstruction; perfluoropropane; pulmonary MRI; ventilation

Mesh:

Year:  2020        PMID: 32060989     DOI: 10.1002/mrm.28209

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  3 in total

Review 1.  Novel imaging techniques for cystic fibrosis lung disease.

Authors:  Jennifer L Goralski; Neil J Stewart; Jason C Woods
Journal:  Pediatr Pulmonol       Date:  2021-02

2.  Evaluation of fluorine-19 magnetic resonance imaging of the lungs using octafluorocyclobutane in a rat model.

Authors:  Yurii Shepelytskyi; Tao Li; Vira Grynko; Camryn Newman; Francis T Hane; Mitchell S Albert
Journal:  Magn Reson Med       Date:  2020-08-12       Impact factor: 4.668

3.  Comparison of single breath hyperpolarized 129 Xe MRI with dynamic 19 F MRI in cystic fibrosis lung disease.

Authors:  Andrew McCallister; Sang Hun Chung; Michael Antonacci; Margret Z Powell; Agathe S Ceppe; Scott H Donaldson; Yueh Z Lee; Rosa Tamara Branca; Jennifer L Goralski
Journal:  Magn Reson Med       Date:  2020-08-08       Impact factor: 4.668

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.