Literature DB >> 3205142

Heating effects of metallic implants by MRI examinations.

R Buchli1, P Boesiger, D Meier.   

Abstract

Magnetic radiofrequency fields applied in magnetic resonance imaging examinations induce electrical currents in metallic implants. These eddy currents may heat up the implants and thus may be capable of causing localized tissue heating. The rf power deposition and the joule heating of the implant can be calculated by solving Maxwell's equations for the specific problem. First, extreme in vitro worst-case experiments were performed with a large and very thin aluminum sheet, which was placed in a 1.5-T MRI device in a position parallel to the magnetic rf field. In agreement with the theoretical results the temperature rise of a thermally insulated sheet amounted to only 0.08 degrees C after a 15-min MRI examination at 64 MHz. No temperature rise in the aluminum sheet could be measured for a sheet immersed in a saline solution. Second, in vitro experiments with a hip joint prosthesis and an osteosynthetic plate were performed to confirm the theoretical results, which predict nearly no temperature rise in the metallic implants. No temperature rise in the implants could be measured.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3205142     DOI: 10.1002/mrm.1910070302

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  11 in total

1.  Mutual interferences and design principles for mechatronic devices in magnetic resonance imaging.

Authors:  Ningbo Yu; Roger Gassert; Robert Riener
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-09-02       Impact factor: 2.924

2.  [Effects of magnetic resonance tomography on upper eyelid implants].

Authors:  T Schrom; H Bauknecht; A Berghaus; H Scherer
Journal:  HNO       Date:  2005-08       Impact factor: 1.284

3.  Interaction between grounding pads used for RF ablation therapy and magnetic resonance imaging.

Authors:  Christina Schraml; Hansjörg Graf; Andreas Boss; Stephan Clasen; Martin Leibfritz; Philippe L Pereira; Claus D Claussen; Fritz Schick
Journal:  MAGMA       Date:  2005-12-13       Impact factor: 2.310

Review 4.  Nuclear magnetic resonance in clinical pharmacology and measurement of therapeutic response.

Authors:  W H Aellig
Journal:  Br J Clin Pharmacol       Date:  1990-02       Impact factor: 4.335

5.  Reducing RF-induced Heating near Implanted Leads through High-Dielectric Capacitive Bleeding of Current (CBLOC).

Authors:  Laleh Golestanirad; Leonardo M Angelone; John Kirsch; Sean Downs; Boris Keil; Giorgio Bonmassar; Lawrence L Wald
Journal:  IEEE Trans Microw Theory Tech       Date:  2019-01-01       Impact factor: 3.599

6.  A Virtual Patient Simulator Based on Human Connectome and 7 T MRI for Deep Brain Stimulation.

Authors:  Giorgio Bonmassar; Leonardo M Angelone; Nikos Makris
Journal:  Int J Adv Life Sci       Date:  2014

7.  Reconfigurable MRI technology for low-SAR imaging of deep brain stimulation at 3T: Application in bilateral leads, fully-implanted systems, and surgically modified lead trajectories.

Authors:  Ehsan Kazemivalipour; Boris Keil; Alireza Vali; Sunder Rajan; Behzad Elahi; Ergin Atalar; Lawrence L Wald; Joshua Rosenow; Julie Pilitsis; Laleh Golestanirad
Journal:  Neuroimage       Date:  2019-05-13       Impact factor: 6.556

Review 8.  Magnetic Resonance Sequences and Rapid Acquisition for MR-Guided Interventions.

Authors:  Adrienne E Campbell-Washburn; Anthony Z Faranesh; Robert J Lederman; Michael S Hansen
Journal:  Magn Reson Imaging Clin N Am       Date:  2015-08-12       Impact factor: 2.266

9.  MRI-based multiscale model for electromagnetic analysis in the human head with implanted DBS.

Authors:  Maria Ida Iacono; Nikos Makris; Luca Mainardi; Leonardo M Angelone; Giorgio Bonmassar
Journal:  Comput Math Methods Med       Date:  2013-07-15       Impact factor: 2.238

Review 10.  Patient safety issues in magnetic resonance imaging: state of the art.

Authors:  A Stecco; A Saponaro; A Carriero
Journal:  Radiol Med       Date:  2007-06-11       Impact factor: 6.313